Query: UMLS:C0086543 (
cataract
)
29,165
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
Forty-three patients were examined three months after implantation of a multifocal or bifocal intraocular lens following
cataract
extraction. With far vision correction, simultaneous bifocal function with far acuity better than 0.5 and near acuity better than Nieden 3 was achieved in 95.4% of these cases. Glare sensitivity was tested with the
BAT
and mesopic visual acuity was examined with the Ocutrast. No statistical differences were found between these patients and a control group with monofocal IOLs.
...
PMID:[Diffractive multifocal intraocular lenses. A prospective clinical study]. 231 94
We evaluated two methods of glare testing, the Miller-Nadler Glare Tester (M-NGT, Titmus Optical, Inc.) and the Brightness Acuity Tester (
BAT
, Mentor O & O, Inc.). Resulting Snellen visual acuities both for a control group of normal volunteers and for a study group with
cataract
or posterior capsule opacification were compared using the two glare testers. The decreases in Snellen visual acuities were comparable in the eyes with
cataract
. No glare disability was measured in the control group. There was greater glare disability using the
BAT
compared with the Miller-Nadler test when eyes with posterior capsule opacities were compared.
...
PMID:A clinical comparison of two methods of glare testing. 368 86
This study presents the first clinical and functional results on the implantation of a new multifocal IOL model, the Domilens type PROGRESS 1. A group of 20 patients underwent extracapsular extraction of
cataract
with continuous circular capsulorhexis and IOL implantation in the capsular bag. In 65% of the cases, final visual acuity from a far distance proved to be greater than or equal to 8/10 without correction, while visual acuity from a short distance was J2 without the need of additional lenses.
BAT
identified a decrease in visual acuity of 0.01 Snellen lines at a medium lighting level and 0.05 at the maximum level. The perimetric results obtained with the C 30-2 threshold programme of the Humphrey field analyzer showed a foveal sensitivity threshold of 32.5 dB +/- 9.25 dB and a mean defect of -2.22 dB +/- 2.90 dB. The Vistech VCTS 6500 underlined a decrease in the sensitivity to space frequency contrast of 6.0 c/d versus a control group of patients with monofocal IOL (P < 0.05). This reduction involved a wider range of space frequencies (3.0, 6.0, 12.0 c/d) in comparison with a group of phakic subjects (P < 0.05). With the on-off PEV patterns, a slight decrease in contrast sensitivity threshold was found versus patients with monofocal IOL statistically non significant (P > 0.05). At a medium space frequency of 2.33 c/d, a decrease in contrast sensitivity versus phakic subjects (P < 0.05) was observed. Depth of focus went from infinite to 19 cm. from the eye.
...
PMID:[Functional evaluation of a new type of intraocular lens: Domilens type PROGRESS 1]. 818 54