Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: UMLS:C0086543 (cataract)
29,165 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

Forty-three patients were examined three months after implantation of a multifocal or bifocal intraocular lens following cataract extraction. With far vision correction, simultaneous bifocal function with far acuity better than 0.5 and near acuity better than Nieden 3 was achieved in 95.4% of these cases. Glare sensitivity was tested with the BAT and mesopic visual acuity was examined with the Ocutrast. No statistical differences were found between these patients and a control group with monofocal IOLs.
...
PMID:[Diffractive multifocal intraocular lenses. A prospective clinical study]. 231 94

We evaluated two methods of glare testing, the Miller-Nadler Glare Tester (M-NGT, Titmus Optical, Inc.) and the Brightness Acuity Tester (BAT, Mentor O & O, Inc.). Resulting Snellen visual acuities both for a control group of normal volunteers and for a study group with cataract or posterior capsule opacification were compared using the two glare testers. The decreases in Snellen visual acuities were comparable in the eyes with cataract. No glare disability was measured in the control group. There was greater glare disability using the BAT compared with the Miller-Nadler test when eyes with posterior capsule opacities were compared.
...
PMID:A clinical comparison of two methods of glare testing. 368 86

This study presents the first clinical and functional results on the implantation of a new multifocal IOL model, the Domilens type PROGRESS 1. A group of 20 patients underwent extracapsular extraction of cataract with continuous circular capsulorhexis and IOL implantation in the capsular bag. In 65% of the cases, final visual acuity from a far distance proved to be greater than or equal to 8/10 without correction, while visual acuity from a short distance was J2 without the need of additional lenses. BAT identified a decrease in visual acuity of 0.01 Snellen lines at a medium lighting level and 0.05 at the maximum level. The perimetric results obtained with the C 30-2 threshold programme of the Humphrey field analyzer showed a foveal sensitivity threshold of 32.5 dB +/- 9.25 dB and a mean defect of -2.22 dB +/- 2.90 dB. The Vistech VCTS 6500 underlined a decrease in the sensitivity to space frequency contrast of 6.0 c/d versus a control group of patients with monofocal IOL (P < 0.05). This reduction involved a wider range of space frequencies (3.0, 6.0, 12.0 c/d) in comparison with a group of phakic subjects (P < 0.05). With the on-off PEV patterns, a slight decrease in contrast sensitivity threshold was found versus patients with monofocal IOL statistically non significant (P > 0.05). At a medium space frequency of 2.33 c/d, a decrease in contrast sensitivity versus phakic subjects (P < 0.05) was observed. Depth of focus went from infinite to 19 cm. from the eye.
...
PMID:[Functional evaluation of a new type of intraocular lens: Domilens type PROGRESS 1]. 818 54