Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: UMLS:C0040822 (tremor)
18,428 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

Mestranol in combination with ethynodiol diacetate, an oral contraceptive formulation, is isolated from the sample on a partition chromatographic column prior to colorimetric determination. The color reaction which is specific for estrogens is formed by shaking an aliquot of the heptane eluate of mestranol with a 30% methanol-sulfuric acid solution. A collaborative study of the method gave results of 99.8% of added mestranol for the simulated mix and 100.7% of labelled mestranol for the commercial tablet. The method has been adopted as official first aciton.
...
PMID:Colorimetric determination of mestranol in combination with ethynodiol diacetate. 114 Nov 59

The fluorometric benzophenone procedure for diphenylhydantoin has been simplified by eliminating the need for preliminary extraction of plasma with an organic solvent. Assays are done directly on 0.2 ml of plasma by treating it with alkaline permanganate to form benzophenone, extracting the benzophenone with heptane, and then shaking the heptane layer with sulfuric acid and measuring the fluorescence of the acid layer. The assay is highly reproducible, and adequately sensitive to detect 1 mug of the drug per milliliter of plasma. Fluorometric and gas-liquid chromatographic assays of 154 plasmas gave results that were not significantly different, even in the presence of phenobarbital, other barbiturates and anticonvulsant drugs, or of various tranquilizers and other commonly used drugs. The assay is rapid, the unit cost per assay low.
...
PMID:Simplified fluorometric assay for diphenylhydantoin in plasma. 127 83

The cellular lipid patterns of seven strains of microorganisms were examined by gas-liquid chromatography in this preliminary study. The chloroform methanol-soluble lipids were extracted by the Soxhlet method from dried cultures which had been grown at 25 +/- 2 C for 18 hr with mechanical shaking. The cellular extract was methylated by use of a low temperature sulfuric acid method, and the resulting methyl esters were chromatographed. Considerable differences in the lipid patterns among the seven microorganisms tested indicated that this method might be useful for the identification of closely related microbial genera, and possibly for species differentiation.
...
PMID:Lipid patterns of selected microorganisms as determined by gas-liquid chromatography. 486 May 30

A rapid, sensitive method has been developed to study the kinetics of unchanged promethazine (PM) in biological material using a nitrogen-selective flame ionization detector (N-FID). Unchanged PM is distinguished from its desmethyl metabolite. Sample clean-up of several biological fluids (rat plasma, blood, urine, liver and kidney homogenates) was studied and gas chromatographic (GC) conditions optimized. Usually 50 microliters-1.0 ml samples are extracted into n-heptane by shaking with NaOH, re-extracted into H2SO4 and again extracted into n-heptane by addition of NaOH. Finally, the organic phase is separated, concentrated under N2 and PM determined by N-FID. However, a rapid, single-step method requiring only NaOH extraction into n-heptane may be used whenever GC background permits. Imipramine is used as an internal standard for calibration by peak height ratios in the overall range 5--1500 ng PM per sample. Recovery of both methods is high (97--99%) but precision of the single-step method is lower (relative S.D. 10% versus 3--4%). Use of sample volumes up to 1 ml allows accurate determination of concentrations as low as 10 ng/g. Examples of applications to commonly used animal models employing PM are given and simple adaptation for clinical samples suggested.
...
PMID:Rapid, sensitive determination of unchanged promethazine in biological material using a nitrogen-selective flame ionization detector. Identification of metabolites by gas chromatography-mass spectrometry. 739 Dec

The main problem with routine analyses of pentachlorophenol (PCP) and sodium pentachlorophenolate (Na-PCP) in wood and wood-based products is to determine critical PCP-contents. This task requires a reliable analytical method and statistical testing. An analytical procedure is described, which permits the determination of PCP and Na-PCP with sufficient sensitivity and accuracy. A medium size sieve (4 x 4 mm quadratic mesh) was found suitable for the grinding step. Different extraction techniques and solvents were tested systematically. Extraction by a combination of ultrasonication and shaking in the solvent mixture toluene/sulfuric acid showed best recoveries. The eluted PCP and Na-PCP were derivatized with acetic anhydride and determined by GC/ECD. The limits of detection and determination were 0.14 mg/kg and 0.40 mg/kg, respectively.
...
PMID:Trace analysis of pentachlorophenol (PCP) in wood and wood-based products--comparison of sample preparation procedures. 1122 37

Monitoring the removal of carbonate from alkali metal hydroxide (MOH, M = K, Na) solutions with calcium oxide (CaO) was studied using a newly developed method for the determination of trace amounts of total carbonate (TC) in alkaline solutions based on a flow injection (FI) technique coupled with a gas diffusion system. The optimized conditions of the FI system were as follows: the flow rate of each carrier, reaction solution (H2SO4) and receptor solution (Cresol Red, pH 8.9) was 0.25 ml min(-1), the sample size was 0.1 ml and the concentration of H2SO4 in the reaction solution was 0.09 M. The limit of detection of TC by the proposed method was 4 x 10(-7) M. The removal efficiency of carbonate was affected by the amount of CaO added, the shaking time of the solutions and the concentration of MOH. For 1 M NaOH and KOH solution, the removal efficiency of carbonate was about 99% and the concentration of residual carbonate was 4 x 10(-5) and 1.2 X 10(-4) M, respectively, when the amount of CaO added was 2 g l(-1) and the shaking time was 16 h.
...
PMID:Monitoring the removal of carbonate from alkali metal hydroxide solutions using gas diffusion flow injection. 1199 72

The objective of the study was to evaluate the adverse reactions of Loratadine plus Pseudoephedrine Sulfate Repetabs Tables (LTD+PSE Repetabs) (Loratadine 5 mg + Pseudoephedrine 120 mg) twice daily with that of loratadine (5 mg) twice daily and pseudoephedrine (60 mg) quarter daily in the treatment of patients with allergic rhinitis. The study was designed as an investigator-blind, parallel group study. In this study, 56 patients were equally separated into 2 groups and treated for 14 days with either LTD+PSE Repetabs or loratadine + pseudoephedrine tablet. Both groups were comparable in age, gender, weight; baseline systolic blood pressure, diastolic blood pressure and pulse rate. The change of systolic blood pressure, diastolic blood pressure, and pulse rate did not reach clinical significance throughout the study period. There was no significant difference in occurrences of insomnia, palpitation, mouth dryness and anxiety. However, the incidence of patients with tremor at day 14 in the loratadine + pseudoephedrine tablet group was significantly higher than the LTD+PSE Repetabs group (39% vs 10.7%, p-value = 0.03). Furthermore, one patient in the loratadine + pseudoephedrine tablet group had to discontinue medication at day 7 due to insomnia. In conclusion, LTD+PSE Repetabs is well tolerated and has fewer adverse effects when compared to the loratadine + pseudoephedrine tablet.
...
PMID:A comparative study of the side effects between pseudoephedrine in Loratadine plus Pseudoephedrine Sulfate Repetabs Tables and loratadine + pseudoephedrine tablet in treatment of allergic rhinitis in Thai patients. 1232 47

A procedure of clean-up with H2SO4 after extraction with a shaking machine using n-hexane, and fast determination of some organochlorine residues in eggs by GC-ECD with PCB2 and PCB209 as internal standards was established. The test results showed that with this method satisfactory recoveries(84.31%-116.77%), relative standard deviation (6%-18%) and detection limits (0.07 ng/g-0.35 ng/g) could be obtained. In comparing with the Soxhlet method, this method is simpler in pre-treatment, lower in cost and less in sample amount. It can determine organochlorine pesticides and some PCBs in the same extract, simultaneously with enough accuracy, sensitivity and permissible RSD. It is a suitable procedure for determining micro-amounts of organochlorine pollutants in foods. The results showed that p, p'-DDE was detected in maximum; p, p'-DDT next; and PCBs very little, that were usually less than 10 ng/g in the eggs from some Chinese markets. It was found that most of PCBs in eggs were the congeners with 3-5 chlorine atoms.
...
PMID:[Determination of organochlorine pesticides and polychlorinated biphenyl congeners residues in eggs by gas chromatography with electron capture detection (GC-ECD)]. 1254 78

Two typical cleanup methods, sulfuric acid treatment and multi-layer silica gel column chromatography, for the determination of polychlorinated dibenzo-p-dioxins (PCDDs), dibenzofurans (PCDFs) and dioxin-like polychlorinated biphenyls (dioxin-like PCBs) in seventeen food samples were examined and compared. Vegetables, fruits, cereals, fish, meat and dairy foods were extracted by conventional methods (shaking with acetone/n-hexane or with n-hexane after alkaline treatment). The extracts were cleaned up by sulfuric acid treatment or multi-layer silica gel column chromatography, followed by several column chromatographic steps. Of the samples treated, the vegetable, fruit and cereal samples could be directly applied to the multi-layer silica gel column after extraction. However, the samples containing fats and oils such as fish, meat and dairy foods needed to be treated several times with concentrated sulfuric acid before multi-layer column chromatography, because these samples plugged the column with oily residues. Both cleanup methods gave similar values of isomeric concentrations and showed similar efficiency of purification, and the recoveries ranged from 40 to 120%. These results are considered to provide useful data for the efficient analysis of dioxins in foods which have wide-ranging compositions.
...
PMID:Comparison of sulfuric acid treatment and multi-layer silica gel column chromatography in cleanup methods for determination of PCDDs, PCDFs and dioxin-like PCBs in foods. 1260 31

In this work, the feasibility of employing Cyanex 923 as an extractant into the non-cerium REE (rare earth elements) impurity analysis of high-purity cerium oxide was investigated. Through investigations on the choice of the extraction medium, the optimium extraction acidity, matrix Ce4+ effect on the non-cerium REE ion extraction, the optimium extractant concentration and suitable extracting time, and oscillation strengh, it was found that when the phase ratio was at 1:1 and the acicidity was about 2% H2SO4, by gently shaking by hand for about 2 min, 10 mL of 30% Cyanex 923 could not extract even for a 20 ng amount of non-cerium REE3+ ions. However, the extraction efficiency for Ce4+ of 100 mg total amount under the same conditions was about 96%, indicating that a 25-fold preconcentration factor could be achieved. Thus, it was concluded that Cyanex 923 could be used in a REE impurity analysis of 99.9999% or so pure cerium oxide for primary sepapation to elimilate matrix-induced interferences encountered in an ICP-MS (inductively coupled plasma mass spectroscopy) determination.
...
PMID:Cyanex 923 as the extractant in a rare earth element impurity analysis of high-purity cerium oxide. 1522 11


1 2 Next >>