Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: UMLS:C0040822 (tremor)
18,428 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

Adult female little brown bats (Myotis lucifugus) were collected in a church attic in North East, Cecil County, Md. Mealworms (Tenebrio molitor) containing organochlorine pollutants were fed to the bats as follows: 5 bats were dosed at 480 ppm DDE, 12 at 150 ppm DDE, 5 at 1000 ppm polychlorinated biphenyl (PCB; Aroclor 1260), and 12 at 15 ppm PCB. Seven other bats were fed untreated mealworms. The objective was to elevate brain levels of DDE and PCB to lethality and measure these concentrations. During 40 d of dosage, one DDE-dosed bat and two PCB-dosed bats died after exhibiting the prolonged tremor that characterizes organochlorine poisoning. After dosage, surviving bats were starved to elevate brain levels of toxicants, and three additional DDE-dosed bats had tremors before dying. The mean brain concentration of DDE diagnostic of death was estimated as 603 ppm, range 540-670 ppm. This mean is 16-18% higher than means for Mexican free-tailed bats (Tadarida brasiliensis) and common grackles (Quiscalus quiscula), and may indicate less sensitivity. Lethal brain concentrations of Aroclor 1260 were 1300 and 1500 ppm. Such values appear to be higher than values (Aroclor 1254) for brown-headed cowbirds (Molothrus ater). During starvation, DDE-dosed bats lost weight about 24% faster than controls. If smaller amounts of stored DDE cause increases in metabolic rates of nonfeeding bats, as during hibernation or migration, the result could be premature energy depletion and increased mortality.
...
PMID:Effects of DDE and PCB (Aroclor 1260) on experimentally poisoned female little brown bats (Myotis lucifugus): lethal brain concentrations. 679 Jul 23

A simple approach to determine 19 PCB congeners in catfish tissue was presented. A modified QuEChERS method employing high solvent to sample ratio 10:1 was used to improve the extraction recovery of 19 PCB congeners. After salting out by shaking with anhydrous magnesium sulfate and sodium chloride, 1 mL of acetonitrile extract was pipetted into a 2-mL centrifuge tube containing anhydrous magnesium sulfate, primary secondary amine sorbent, and C-18 sorbent. The tube was then shaken and centrifuged to absorb fat and fatty acid residue present in the acetonitrile extract. The acetonitrile extract was analyzed by GC-MS/MS. The excellent sensitivity of GC-MS/MS allows for the direct injection of the samples to detect the low level of the PCB congeners. The method therefore is high throughput, uses fewer consumable lab supplies, and provides excellent sensitivity with an LOQ below 1 ng/g.
...
PMID:Analysis of 19 PCB congeners in catfish tissue using a modified QuEChERS method with GC-MS/MS. 2630 27