Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Pivot Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Target Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Query: UMLS:C0040822 (
tremor
)
18,428
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
Eight years after diagnosis, 40% of MS patients develop a chronically progressive form. Annually we treat approximately 200 patients with progressive MS. Treatment consists of medication, i.e. agents that help to prevent future impairment, or interferon-beta injections, and intervals of mitoxantrone infusions (Novantrone(R)), and in some cases cyclic cyclophosphamide (Endoxan(R)) or nucleoside analogue cladribin (
Leustatin
(R)). Without clear scientific evidence, we recommend unsaturated fatty acids (thistle or sunflower oil), sufficient protein, and freshly prepared fruits and vegetables as a sound basis for remyelination. Remyelination profits from general prophylaxis in the use of ascorbic acid to help prevent urinary infections via acidification, autogenic training to reduce fatigue, improve ventilation of deeper airways, and stimulate vagotonic regeneration, and prevention of unnecessary immune stimulation caused by insects and some food. We recommend the use of sun hats and disencourage blood donation (Allain 1998). Physiotherapy can improve strength, reduce spasticity, and train the patient to compensate for dysbalance and ataxia; supported by beta blockers and good antispastics,
tremor
and gait disturbances can be positively influenced. Music and motion, speech therapy, realistic training of daily activities, and prudent psychotherapy complete the range of measurements to reconstitute as much as possible of the patient's individual freedom. In the individual, we eventually provide prudent technical aids and careful prognostic estimations. Cooperating with local and regional patient networks, we reinforce long-term disease management and spread up-to-date medical research results, and finally gather valuable contextual information and clinical data on an increasingly frequent idiopathic disease of the human central nervous system.
...
PMID:Medical rehabilitation of chronic progressive disseminated encephalomyelitis (MS). 1087 9
The AccuPoint Advanced ATP Hygeine Monitoring System was validated by an AOAC International Performance Tested MethodSM on the detection of ATP from stainless steel surfaces. Neogen Corp.'s system is a lightweight, hand-held diagnostic tool used to validate and verify a hygiene program's effectiveness by detecting organic residues remaining on surfaces and in liquids after cleaning. The system is composed of three primary components: an electronic luminometer, fully self-contained single-use samplers, and software. The system is designed to detect adenosine triphosphate (ATP) at set thresholds and to report the measurement in relative light units (RLU). These thresholds are established by a facility to reflect effective cleaning practices. The instrument compares the measured level of ATP with the established threshold and reports the results as pass, marginal, or fail. A linear dose-response in RLU was observed with pure analyte. In the matrix and microbial studies, detection levels varied depending on the matrix and microorganism tested. Independent laboratory trials confirmed pure analyte and matrix observations. Specificity testing of similar, yet different, compounds resulted in 0 RLU for all except 2'
-deoxyadenosine
5'-triphosphate sodium salt, which showed markedly reduced reactivity when compared with ATP. Also, interference by these compounds was negligible. When disinfectant residues were evaluated for their effect on the test, cleaners increased RLU output to varying degrees. Stability testing showed consistent results between three independently manufactured lots and stable results through the 9 month shelf-life. Additionally, when three readers were compared using electronic light-emitting diodes as the light source, instrument variability was low (<3%). Robustness testing results provided evidence that temperature affects test performance more than
shaking
time, and sampler performance improves as the temperature increases to room temperature. These results provided evidence that the AccuPoint Advanced ATP Hygiene Monitoring System produces consistent and reliable data for the evaluation of sanitation program effectiveness on stainless steel surfaces in food processing and food service facilities.
...
PMID:Validation of the AccuPoint Advanced ATP Hygiene Monitoring System for Sanitation Monitoring Through Detection of ATP from Stainless Steel Surfaces. 2811 34