Query: UMLS:C0039730 (
thalassemia
)
10,305
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
This paper demonstrates the diagnosis of beta-
thalassemia
by capillary electrophoresis in conjunction with laser-induced fluorescence using poly(ethylene oxide) (PEO) solutions in the presence of electroosmotic flow (EOF). During the electrophoretic separation, PEO solution entered a capillary from the anodic vial by EOF. The separation of a mixture of the polymerase chain reaction (PCR) products (330 and 334 base pairs) from a healthy person and a beta-
thalassemia
patient was accomplished within 15 min at 15 kV using 1.5% PEO containing 2 M urea at 30 degrees C. The electropherogram patterns instead of migration times were used to diagnose beta-
thalassemia
, with an accuracy of 100% for the analyses of 11 blood samples from suspected patients. After injecting a large volume of the mixture to the capillary filled with 800 mM
Tris
-borate buffer (pH 10.0), the DNA fragments stacked due to increases in viscosity and sieving when migrating into 1.5% PEO solution. As a result of improved sensitivity, only 15 PCR cycles were required when using 500 ng of DNA templates. The results shown in this study indicate the potential of this simple, rapid, and cost-effective method for the diagnosis of beta-
thalassemia
.
...
PMID:Fast and sensitive diagnosis of thalassemia by capillary electrophoresis. 1511 99
Hemoglobin (Hb) chains have been analyzed traditionally by cellulose acetate electrophoresis after sample extraction with acetone and denaturation with concentrated urea in order to detect
thalassemia
(Thal). A few capillary electrophoresis (CE) methods have been also described for separation of Hb chains also after sample extraction. We describe a CE method for analysis of Hb chains without sample preparation. Red blood cells were diluted (hemolyzed) in water and injected directly onto the capillary. The separation was performed in concentrated phosphate buffer at pH 12.6 and 2.15. Under these conditions of pH and buffer concentration, the chains were denatured and separated from the heme during electrophoresis. The common variants of the beta-chains, such as beta(S), beta(C), and beta(E), are also separated from each other. The intact Hb molecule is analyzed using the same sample and CE conditions but in an arginine-
Tris buffer
, pH 8.6. The data from the three separations are used to complement each other for interpretation of the presence of Hb variants and for
thalassemia
. The main advantages of this method are simplicity and speed. This method illustrates the flexibility and simplicity of the CE for analysis of the hemoglobinopathies.
...
PMID:Simplified hemoglobin chain detection by capillary electrophoresis. 1569 Apr 30
A flow injection (FI)-reduced volume column system was developed for hemoglobin (Hb) typing to be used as an initial screening method for
thalassemia
. The column was packed with 140 microl diethylaminoethyl (DEAE)-Sephadex A-50 ion exchange beads. Hb can be separated using
Tris
-HCl buffer solution with pH gradient 8.5-6.5 and then monitored spectrophotometrically at 415 nm. The hemolysate of 40 blood samples from packed red cells were screened for
thalassemia
by determining the amount of HbA(2) and HbE present. The proposed system was able to predict positive test results from those samples with beta, E-trait and EE homozygous
thalassemia
, Hb types that were independently identified following the conventional method at the hospital laboratory. Advantages of the proposed system over the conventional column technique include low amount of reagents and blood sample needed, short analysis time and low cost. Each analysis required only 80 microl of 50 times diluted packed cells, which is equivalent to 1.6 microl undiluted packed cells, and it can be completed in only 35 min. This simple FI-reduced volume column system was demonstrated to be an economic alternative system for Hb typing to initially screen some types of
thalassemia
such as beta-trait, E-trait and EE-homozygous which are commonly found in Thailand.
...
PMID:A simple flow injection-reduced volume column system for hemoglobin typing. 1896 42