Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Pivot Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Target Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Query: UMLS:C0037315 (
sleep apnea
)
8,000
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
EEG color density spectral array enables quick evaluation of sleep. The aim of the study was to evaluate if an easily calculated sleep score based on this method could be used to assess the improvement of sleep after nasal continuous positive airway pressure (CPAP) in patients with
sleep apnea syndrome
(
SAS
). Eight hours of sleep are displayed on a single sheet along with EEG amplitude, 2 EEG channel spectra (
FFT
), electromyogram envelope and electro-oculogram. The x-axis corresponds to time, the y-axis to EEG frequency (range 0-16 Hz), and the color to the frequency power. This system allows the detection of sleep spindles, REM sleep and deep sleep (stages 3 and 4) as well as the evaluation of the sleep cyclic organization and its fragmentation by apnea. Based on these findings a sleep score is calculated. Eight young normal subjects were successively recorded as well as 15
SAS
patients and with and without nasal CPAP. During the 1st night, the sleep score was lower in
SAS
patients than in normal subjects. With CPAP the apnea number decreased and the sleep score returned to normal in all patients except 1. A positive correlation was found between sleep score and duration of stage 2, stage 3 or REM sleep. A negative correlation was found between sleep score and the apnea index. This sleep score enables a quick and reliable evaluation of sleep in patients with
SAS
before and during nasal CPAP.
...
PMID:Color density spectral array for quick evaluation of sleep during nasal continuous positive airway pressure. 896 62
Attempts to elucidate the complex pathophysiology of chronic fatigue syndrome (CFS) must consider subjective and objective sleep. Several reports of CFS showed the high rate of sleep disturbance such as insomnia, hypersomnia, circadian rhythm sleep disorder,
sleep apnea
/hypopnea syndrome and so on. To analyze pulse wave continuously in sleep of CFS patients by laser blood flowmeter, we set base line component (0.01-0.08 Hz) and pulse wave component(0.70-1.50 Hz). Results of
FFT
analysis indicate that the CFS can have at least three subtypes of pulse dynamics in sleep. There probably are different types of illnesses now contained within the CFS construct, in which identifying subtypes of sleep disturbance can be one important key.
...
PMID:[Sleep disturbance in chronic fatigue syndrome]. 1756 91