Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Pivot Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Target Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Query: UMLS:C0034065 (
pulmonary embolism
)
14,979
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
The purpose of this study was to compare the performance of 2D vs. 3D time-of-flight (TOF) methods in imaging the normal pulmonary arteries with commercially available 1.0 T equipment. The study was conducted in 20 volunteers and 7 patients with suspected
pulmonary embolism
(PE). To reduce artifacts caused by cardiac and respiratory motion, MR images were acquired in volunteers using two-dimensional (2D), gradient-recalled echo (GRE), breath-hold techniques, and three-dimensional (3D) acquisitions. Sagittal thin (6-MM) segmented k-space 2D sections obtained with cardiac gating during systole (turboFLASH, TR/TE9/6 ms, 14 segments of 9 lines) and incremented flip-angles (TONE), and 50-mm 3D volume TONE acquisitions with 32 partitions (
FISP
, TR/TE34/10ms) were successively performed. In the second phase of the study, patients were examined only with the 3D technique. Images of volunteers were qualitatively and quantitatively analyzed. S/N ratios were statistically compared by means of the paired-sample Wilcoxon ranked-signed test, a value of p < .05 being significant. In volunteers, 3D acquisitions displayed significantly more segment-order pulmonary arteries on average than did 2d acquisitions displayed significantly more segment-order pulmonary arteries on average than did 2D acquisitions (2.95 +/- 0.64 vs. 2.2 +/- 0.85, respectively; p < .01). Moreover, the signal intensity of arteries within the lungs was less homogeneous in the 2D than in the 3D technique, with a signal intensity ratio between peripheral and proximal arteries of 63% +/- 7% and 73% +/- 2%, respectively (p < .05). In patients, no erroneous diagnoses were obtained using the 3D technique. 3D images of normal lungs provide MR angiograms of better quality than do 2D images, and require less contribution from subjects because they are performed in free breathing. Ongoing improvements in MR sequences and further studies are now necessary to assess the value of 3D TONE MRA in the diagnosis of PE.
...
PMID:Pulmonary time-of-flight MR angiography at 1.0 T: comparison between 2D and 3D tone acquisitions. 858 73
The diagnostic performance of magnetic resonance (MR) sequences for displaying different levels of pulmonary artery involvement in
pulmonary embolism
(PE) has rarely been reported but is essential for critically ill and emergency patients. The aim of the present study was to analyze the diagnostic accuracy of true fast imaging with steady-state precession (true
FISP
), MR pulmonary angiography (MRPA) and volume-interpolated body examination (VIBE) for PE detection in comparison to CT pulmonary angiography (CTPA), which is the reference standard. A total of 21 patients with confirmed deep venous thrombosis suspected of having PE were enrolled. Emboli were evaluated on per-patient and per-vessel bases. The evidence of PE on a per-vessel basis was classified into central, lobar and segmental levels, and 27 vessel segments per patient were analyzed for a total of 567 vessel segments in all patients. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated. Receiver operating characteristic curves were drawn to compare differences in sequences. A total of 158 pulmonary vessels were involved with emboli on CTPA, 58 of which were identified by true
FISP
, 63 by MRPA and 94 by VIBE. On per-patient and per-vessel bases, the sensitivity was 81.3 and 36.7%, respectively, for true
FISP
, 82.4 and 56.3%, respectively, for MRPA, and 94.4 and 68.1%, respectively, for VIBE; the specificity was 80.0 and 99.8%, respectively, for true
FISP
, 100 and 99.2%, respectively, for MRPA, and 100 and 99.2%, respectively, for VIBE. The respective PPV was 92.9 and 98.3% for true
FISP
, 100 and 95.5% for MRPA, 100 and 96.9% for VIBE. The NPV was 57.1 and 80.3%, respectively, for true
FISP
, 50.0 and 88.2%, respectively, for MRPA, and 75.0 and 89.8%, respectively, for VIBE. In conclusion, enhanced VIBE surpassed the other two sequences in revealing PE, particularly in segmental analysis, which is essential for emergency patients who have contraindications for receiving iodinated contrast and those who have concerns about the ionizing radiation.
...
PMID:Diagnostic accuracy of true fast imaging with steady-state precession, MR pulmonary angiography and volume-interpolated body examination for pulmonary embolism compared with CT pulmonary angiography. 3327 72