Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Pivot Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Target Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Query: UMLS:C0034063 (
pulmonary edema
)
10,665
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
We examined the hypothesis that the degree of inflation of the lungs at the time of harvest may have an important role in postpreservation function. Lungs of donor dogs randomly assigned to groups 1 (n = 5) and 2 (n = 5) were ventilated with large tidal volumes (tidal volume, 25 ml/kg; positive end-expiratory pressure, 5 cm H2O; respiratory rate, 12 breaths/min, inspired oxygen fraction 1.0) and were inflated to 30 cm H2O for 15 seconds before pulmonary artery flush and again immediately before tracheal crossclamping. In group 3 (n = 5) donor lungs were normally ventilated (tidal volume, 12.5 ml/kg, positive end-expiratory pressure 0 cm H2O; respiratory rate 12 breaths/min, inspired oxygen fraction, 1.0) and were not hyperinflated before pulmonary artery flushing; the trachea was crossclamped at end-inspiration. In groups 1 and 3 a large bolus (25 micrograms/kg) of prostaglandin E1 was injected into the pulmonary artery before flushing and was also added to the pulmonary artery flush solution (500 micrograms/L). A rapid (approximately 50 seconds), high-volume mm Hg), hypothermic (4 degrees C) pulmonary artery flush was performed in all hypothermic (4 degrees C) pulmonary artery flush was performed in all groups with modified Euro-Collins solution. Heart-lung blocks were stored at 4 degrees C for approximately 29 hours before left single lung allografting. An inflatable cuff was placed around the recipient right pulmonary artery, allowing independent study of the transplanted lung. Hyperinflated lungs harvested with or without prostaglandin E1 provided equivalently excellent early posttransplant function (arterial oxygen tension [mean +/- standard deviation]: group 1; 503 +/- 45, vs group 2; 529 +/- 150 mm Hg; inspired oxygen fraction 1.0). Mean arterial oxygen tension was significantly lower in group 3 (116 +/- 78 mm Hg) than in either groups 1 or 2 (p < 0.0002 for either comparison). Copious reperfusion
pulmonary edema
was a constant feature in group 3 but was not seen in groups 1 and 2. All 10 recipients in groups 1 and 2 survived the 3-day assessment period without difficulty; two of the five recipients in group 3 died during initial unilateral perfusion of the transplanted lung. Donor hyperventilation and inflation to 30 cm H2O before hypothermic storage can help provide excellent posttransplantation lung function after 30-hour preservation, with or without prostaglandin E1 pretreatment. We speculate that this improvement may be due to effects of increased lung volume on pulmonary vascular tone and/or surfactant metabolism.
J Thorac
Cardiovasc
Surg 1992 Oct
PMID:Reliable thirty-hour lung preservation by donor lung hyperinflation. 140 66
Orthoclone (OKT-3), a monoclonal antibody, is an effective immunosuppressant in organ graft recipients. One of the reported side effects is serious
pulmonary edema
, heart failure, hyperdynamia, and elevation of blood pressure. It should be assessed whether patients treated with OKT-3 benefit from antihypertensive therapy with a calcium channel blocker before and during the allograft rejection therapy to prevent from cardiovascular side effects. To assess a preventive cardiovascular effect of therapy with nitrendipine before and during the OKT-3 rejection therapy, the patients studied (n = 28) were randomly allocated to two study groups. Group a without nitrendipine comprised 15 patients, and group b with 2 x 10 mg of nitrendipine daily comprised 13 patients. In study group a (without nitrendipine therapy), in 8 of 15 patients, there was a short-lasting increase in blood pressure during 3 h after the first injection of OKT-3 by 20.0 +/- 12.8 (systolic)/10.1 +/- 6.7 (diastolic) mm Hg. Whereas this initial rise of blood pressure on the first day was accompanied by an increase in heart rate by 24.1 +/- 10.8 beats/min, the longer-lasting increase in blood pressure at day 2 was not associated with significant changes in heart rate. In group b (patients receiving 2 x 10 mg of nitrendipine before OKT-3 therapy was started and during the whole treatment course), in 3 of 13 patients, a short increase in blood pressure (13.7 +/- 2.9/7.8 +/- 5.1 mm Hg) was recorded 5 h after the first dose of OKT-3.(ABSTRACT TRUNCATED AT 250 WORDS)
J
Cardiovasc
Pharmacol 1991
PMID:Cardiovascular side effects after renal allograft rejection therapy with Orthoclone: prevention with nitrendipine. 172 64
In anesthetized and ventilated guinea pigs, intravenous injection of ET-1, ET-2, or ET-3 induced similar rapid and dose-related increases in pulmonary inflation pressure (PIP) and mean arterial blood pressure (MABP). Indomethacin inhibited the increase in PIP evoked by ET-1, ET-2, or ET-3, whereas the changes in MABP following injection of the various ET isotypes were not significantly affected. Injection of ET-1, ET-2, or ET-3 via the pulmonary artery of isolated guinea pig lungs induced similar dose-dependent increases in PIP and pulmonary perfusion pressure (PPP), thromboxane B2 (TxB2) release, and formation of
lung edema
. Indomethacin (5 microM), added to the perfusion medium, significantly inhibited the alterations of PIP, PPP, TxB2 release, and
lung edema
formation evoked by the three ET isoforms. Intravenous injection of 1 nmol/kg of big ET-1 to guinea pigs did not induce significant changes in PIP and MABP. When administered at a dose of 10 nmol/kg, big ET-1 provoked marked slow-developing and sustained increases in PIP and MABP. When big ET-1 was incubated in vitro with either alpha-chymotrypsin or pepsin and injected into guinea pigs at a dose of 1 nmol/kg, marked rapid bronchoconstrictor and pressor responses were observed. The present results demonstrate that ET-1, ET-2, and ET-3 exert comparable bronchopulmonary and pressor activities in the guinea pig. On the contrary, big ET-1 exhibits moderate direct bronchoconstrictor and pressor effects and its hydrolysis by proteases appears to be essential for expression of its full activity.
J
Cardiovasc
Pharmacol 1991
PMID:Bronchopulmonary and pressor activities of endothelin-1 (ET-1), ET-2, ET-3, and big ET-1 in the guinea pig. 172 70
Embolization of parts of mechanical valves has been reported since the inception of prosthetic valve implantation. We report here two cases of embolization of one hemileaflet of a Duromedic bileaflet prosthesis in the mitral position due to a pivot fracture. Both presented with moderately severe mitral regurgitation and
pulmonary edema
and were successfully managed by replacement of the malfunctioning prostheses. The embolised disc was located in the left common iliac artery by abdominal ultrasound and removed by an inguinal, retroperitoneal approach with low morbidity. Both patients left hospital and are doing well to-date.
Thorac
Cardiovasc
Surg 1991 Dec
PMID:Leaflet embolisation from Duromedics valves: a report of two cases. 178 45
This report describes a 62-year-old patient with ischemic dilated cardiomyopathy who presented
pulmonary edema
during cardiac catheterization. Bolus administration of nicardipine (5 mg in 5 min) into the pulmonary artery determined prompt recovery from the crisis and optimal hemodynamic conditions for completion of the catheterization. The action of the drug was mediated by the rapid reduction of the left ventricular preload and afterload. We believe that bolus administration of nicardipine is useful in treating episodes of acute left ventricular insufficiency.
Cardiovasc
Drugs Ther 1991 Apr
PMID:Pulmonary edema during cardiac catheterization successfully treated with bolus administration of nicardipine. 185 58
Three cases are reported of unilateral
pulmonary edema
, two following rapid reexpansion after prolonged tension pneumothorax, with total collapse of the right lung and one after reexpanded atelectasis following left intrabronchial obstruction. In all cases decrease of blood pressure and tachycardia not responding to intravenous fluid substitution were already present within the first 15 min after chest drainage or after removal of the intrabronchial obstruction. The preexistent dyspnea failed to improve. A cloudy opacity of the reexpanded lung was found immediately after drainage in 2 cases. After immediate application of a continuous positive airway pressure mask no more extensive therapy was necessary in one patient. The two others in whom treatment was begun with more than 1 hour delay required artificial ventilation and adrenergics for 2 and 4 days, respectively.
Thorac
Cardiovasc
Surg 1991 Jun
PMID:The importance of early detection and therapy of reexpansion pulmonary edema. 188 81
The authors encountered a patient with an indwelling central venous catheter who presented with
pulmonary edema
after the catheter hub was disconnected. Pulmonary arteriography demonstrated diffuse peripheral vasoconstriction, decreased arterial-to-venous transit time, and arterial occlusions. The former two findings allowed the authors to prospectively suggest the diagnosis of pulmonary air embolism.
Cardiovasc
Intervent Radiol
PMID:Pulmonary air embolism: case report. 191 40
At Stanford University, a Novacor left ventricular assist system (Baxter Healthcare Corporation, Novacor Division, Oakland, Calif.) was placed as a bridge to heart transplantation in 13 patients. During the hospitalization preceding device implantation, all patients were receiving inotropic support for biventricular failure, 11 had
pulmonary edema
, 6 had life-threatening ventricular arrhythmias, 5 had liver dysfunction with coagulopathy, and 2 had renal failure necessitating artificial support. The mean cardiac index before implantation of the Novacor system was 1.5. All survivors with the Novacor device had a dramatic increase in cardiac output (mean cardiac index = 3.1). One patient with cardiac allograft rejection died during implantation of the left ventricular assist system. Two patients died of pulmonary sepsis and multiorgan failure after the device was implanted. All patients who had the Novacor device implanted for more than 7 days were able to walk and ride stationary bicycles while awaiting transplantation. Ten patients (77%) underwent successful heart transplantation after a mean of 18 days' support with the Novacor device. One patient died of presumed sepsis 2 days after transplantation. Nine patients (90%) are alive 4 months to 6 years after transplantation. In the overall United States experience, 68 patients (as of May 1990) have had a Novacor left ventricular assist device implanted. Five were still being supported, 39 had received a transplant (62%), and 35 patients (90%) survived the transplant hospitalization (1 died later). No instances of device failure have occurred. Overall, the Novacor assist system provided effective bridging to transplantation, with posttransplant survival similar to results after routine transplantation. Modifications and improvements based on this clinical experience have been made in the areas of patient selection, techniques of operative placement, postoperative management, and design of the assist system. Isolated left heart support with a fully implantable left ventricular assist system will be offered as an alternative to heart transplantation for selected patients by 1992.
J Thorac
Cardiovasc
Surg 1991 Oct
PMID:Clinical experience with the Novacor ventricular assist system. Bridge to transplantation and the transition to permanent application. 192 34
Repair of total anomalous pulmonary venous connection was performed on 31 patients aged 12 days to 14 years (18 less than 6 months). The connection type was supracardiac in 20 cases, cardiac in nine, infracardiac in one case and mixed in one. Deep hypothermia and circulatory arrest were used in 23 cases (74%). In supracardiac type cases the atrial septal defect was closed through the left atriotomy, without enlargement of the left atrium. Extubation in the operating room was possible in 26 cases (84%). Three patients (9.6%) died, one (with connection to the coronary sinus) soon after operation, due to a management error, another (with connection to the right superior vena cava) of
pulmonary edema
, and an infant with mixed-type connection 1 week postoperatively, presumably from an arrhythmia. No patient required reoperation because of late pulmonary venous stenosis. There were no late deaths. The technique of elevating the cardiac apex provided excellent exposure in the supracardiac and infracardiac types. Progressively earlier referral during the study period facilitated prompt operation and improved patient salvage.
Scand J Thorac
Cardiovasc
Surg 1991
PMID:Total anomalous pulmonary venous connection. 194 13
Respiratory support by means of arteriovenous extracorporeal membrane oxygenation driven by systemic arterial pressure, in contrast to pump-driven venoarterial extracorporeal membrane oxygenation, is attractive because of its simplicity and lack of trauma to formed blood elements. Although arteriovenous extracorporeal membrane oxygenation has been shown to improve arterial blood gases, useful levels of arteriovenous extracorporeal membrane oxygenation shunt flow may exert detrimental effects on systemic and pulmonary hemodynamics. Therefore the hemodynamic consequences of arteriovenous extracorporeal membrane oxygenation were studied in 11 dogs that were anesthetized, heparinized, and their lungs mechanically ventilated (FIO2 = 0.21) before and after induction of oleic acid
pulmonary edema
. The data indicate that arteriovenous extracorporeal membrane oxygenation shunt flows adequate to improve arterial blood gases resulted in significant changes in peripheral vascular resistance (-46%; p less than 0.05), systemic arterial blood pressure (-20%; p less than 0.05), and cardiac output (+110%; p less than 0.05). Dopamine infusion (5 micrograms/kg/min) proved to be more effective than volume expansion (15 ml/kg) in maintaining cardiac output, arterial blood pressure, and arterial blood gases. We conclude that pumpless arteriovenous extracorporeal membrane oxygenation, at flow rates adequate for respiratory support, can adversely alter systemic hemodynamics. However, these effects can be beneficially modulated by a moderate dose of inotropic medication.
J Thorac
Cardiovasc
Surg 1990 Apr
PMID:Hemodynamic response to pumpless extracorporeal membrane oxygenation. 210 83
<< Previous
1
2
3
4
5
6
7
8
9
10
Next >>