Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Pivot Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Target Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Query: UMLS:C0032273 (
pneumoconiosis
)
1,578
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
The study presents data comparing the new tumour marker, ProGRP, with the established markers, NSE, CYFRA 21-1 and CEA in the diagnosis of lung cancer. ProGRP as well as NSE have been reported to be useful markers for staging and monitoring treatment in patients with small cell lung cancer (SCLC). In order to determine the differences in the sensitivity and/or specificity particularly with regard to benign lung diseases, the present study investigated ProGRP in comparison to NSE, CEA and CYFRA 21-1 usually used in lung cancer. ProGRP was quantitatively detectable with an ELISA. So far 192 newly-diagnosed lung cancer patients including 51 SCLC have been examined. Served as controls: 124 subjects i.e. 50 patients with
pneumoconiosis
, 22 patients with obstructive airway diseases, 34 patients with acute inflammatory lung diseases and 18 healthy persons. Significantly elevated tumour marker concentrations were found for ProGRP and NSE in SCLC. At a specificity of 95%, ProGRP and NSE showed comparable sensitivities (68.6% and 74.5%) in SCLC. ProGRP also reached high levels in patients with limited disease status (sensitivity ProGRP: 72.2%, NSE 66.7%). Initial follow-up studies indicated that ProGRP can be used to monitor disease under chemotherapy. In non-small cell lung carcinomas, CYFRA 21-1 was the leading marker with 58.9% sensitivity where ProGRP seldom revealed positive results. ProGRP is a valuable tumour marker for the detection and monitoring of SCLC and a good tool for discriminating
NSCLC
versus SCLC.
...
PMID:Pro-gastrin-releasing peptide (ProGRP), neuron specific enolase (NSE), carcinoembryonic antigen (CEA) and cytokeratin 19-fragments (CYFRA 21-1) in patients with lung cancer in comparison to other lung diseases. 1282 Mar 18
The purpose of this study was to explore the accuracy of (18)F-fluorodeoxyglucose (FDG)-positron emission tomography/computed tomography (PET/CT) in the assessment of mediastinal lymph node in coal workers who had
non-small cell lung cancer
. We retrospectively reviewed 42 retired coal workers who had lung cancer without distant metastasis, between May 2007 and May 2010. Regarding the mediastinal lymph nodes, when the standard uptake value was greater than 2.5, it was considered "malignancy positive." After histological examination of the mediastinal lymph nodes, anthracotic and metastatic ones were detected. The results of PET/CT were analyzed to determine its accuracy. Of these 42 patients, PET/CT detected 47 positive mediastinal lymph nodes in 24 patients with a mean SUV maximum of 6.2 (2.6-13.8). One hundred and thirty-one mediastinal lymph node foci were dissected. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of FDG-PET/CT in detecting nodal metastases were 84% (16/19), 65% (15/23), 66% (16/24), 83% (15/18), and 74% (31/42) on a per-patient basis, respectively. Mediastinal node staging with FDG-PET/CT in coal workers is insufficient due to the high false-positive rates due to the presence of
pneumoconiosis
. In these patients, an invasive technique such as mediastinoscopy seems mandatory for confirmation of ipsilateral or contralateral mediastinal lymph node metastasis.
...
PMID:Accuracy of positron emission tomography in mediastinal node assessment in coal workers with lung cancer. 2138 Jul 83