Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: UMLS:C0029713 (immaturity)
4,335 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

To investigate the features of erythrocyte metabolism in extremely immature infants, we assayed 21 enzyme activities and glutathione level in cord erythrocytes from 28 extremely low-birth-weight infants (ELBWI; defined as birth weight <1,000 g). The results were compared with those from normal adults and non-neonatal reticulocyte-rich controls. Statistical analysis revealed that activities of six enzymes (glucosephosphate isomerase, phosphoglycerate kinase, monophosphoglycerate mutase, enolase, glucose-6-phosphate dehydrogenase (G6PD), and glutathione reductase) were significantly higher, and those of eight other enzymes (phosphofructokinase, 6-phosphogluconate dehydrogenase (6PGD), glutathione peroxidase, adenylate kinase, adenosine deaminase, acetylcholinesterase, NADH methemoglobin reductase, and catalase) were lower in ELBWI taking their marked reticulocytosis into consideration. The 6PGD/G6PD ratio, which is consistently unchanged under various physiological and pathological conditions, was markedly reduced in ELBWI. Our results support the previous reports that neonatal erythrocytes have a unique metabolic pattern which is different from that of adult erythrocytes, and also suggest that the 6PGD/G6PD ratio might be an index for the developmental immaturity of fetal erythrocytes. This is the first report describing the pattern of erythrocyte enzyme activities in ELBWI.
...
PMID:Erythrocyte enzyme activities in cord blood of extremely low-birth-weight infants. 1050 2

In newborn and premature infants whose lung immaturity entails a limited capacity for O2 detoxification, the use of supplemental oxygen should be continuously and non-invasively monitored. Pulse oximetry and transcutaneous O2 monitoring are the systems most used in the NICU. Major limitations of pulse oximetry are motion artifact, sensitivity to excessive light, cutaneous hypoperfusion, hypothermia, venous congestion, arterio-venous shunting, strong skin pigmentation, anemia and high percentage of abnormal hemoglobin. Alarm habituation is a further major risk. New oxymeters show less motion, artifact and higher accuracy during low oxygen saturation. The accuracy during high oxygen saturation is very dependent on the specific oxymeter model used. Transcutaneous O2 monitoring is usually combined with transcutaneous PCO2 monitoring, hence enabling evaluation of oxygenation as well as ventilation. A major risk of this method is related to the heated electrode sensor, which can induce skin burns. A combined ear sensor for pulse oximetry and PCO2 monitoring seems promising.
...
PMID:[Oxygen therapy in newborn: equipments for non-invasive monitoring]. 1576 30