Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Pivot Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Target Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Query: UMLS:C0027627 (
metastases
)
103,950
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
The clinical tolerability and diagnostic value of
Resovist
as a new superparamagnetic iron oxide contrast medium was studied in 30 patients with malignant focal liver lesions (28
metastases
, 2 HCC) within a phase II multicenter study. Magnetic resonance imaging (MRI) was performed at 1.0 Tesla with T1-weighted FLASH- and T2-weighted spin echo sequences before and following intravenous injection of
Resovist
at three different dose groups (4, 8 and 16 mumol Fe/kg). Liver signal intensity was significantly reduced on post-contrast images, while malignant focal liver lesions showed no signal changes.
Resovist
improved tumor liver contrast and lesion-conspicuity, especially for lesions smaller than 1 cm. The dose of 8 mumol Fe/kg was sufficient to achieve diagnostic tumor-liver contrast. Compared to images directly after injection, the number of detected lesions did not improve until 70 min later. There were no significant changes in vital signs (heart rate, blood pressure) or laboratory values until 72 h post-injection.
...
PMID:[New super-paramagnetic iron particles for MRI. Phase II study of malignant liver tumors]. 756 92
Extensive preoperative assessment of hepatic
metastases
is required in colon cancer patients. We report a case in whom the preoperative investigation by ultrasound scan and contrast-enhanced computed tomography revealed numerous cystic lesions of the liver, suspicious of von Meyenburg complex. Magnetic resonance and magnetic resonance cholangiographic images demonstrated typical features of von Meyenburg complex. Further
Resovist
-enhanced magnetic resonance imaging detected two hemangiomas in addition to the multiple cystic lesions. So-called Kupffer cell imaging strongly helped the detection of these hemangiomas, and a combination of various magnetic resonance pulse sequences was of great value for the differential diagnosis of cystic lesions and hemangiomas. In cases in whom conventional imaging studies fail to give a definite diagnosis, such as in the present case, superparamagnetic iron oxide-enhanced magnetic resonance imaging is meaningful for adequate preoperative staging.
...
PMID:Resovist-enhanced MRI for preoperative assessment of colorectal hepatic metastases: a case of multiple bile duct hamartomas associated with colon cancer. 2189 8
Superparamagnetic iron oxide (SPIO) MR contrast agents are composed of nano-sized iron oxide crystals coated with dextran or carboxydextran. Two SPIO agents are clinically approved, namely: ferumoxides (Feridex in the USA, Endorem in Europe) with a particle size of 120 to 180 nm, and ferucarbotran (
Resovist
) with a particle size of about 60 nm. The principal effect of the SPIO particles is on T2* relaxation and thus MR imaging is usually performed using T2/T2*-weighted sequences in which the tissue signal loss is due to the susceptibility effects of the iron oxide core. Enhancement on T1-weighted images can also be seen with the smaller
Resovist
. Both Feridex and
Resovist
are approved specifically for MRI of the liver. The difference being that
Resovist
can be administered as a rapid bolus (and thus can be used with both dynamic and delayed imaging), whereas Feridex needs to be administered as a slow infusion and is used solely in delayed phase imaging. In the liver, these particles are sequestered by phagocytic Kupffer cells in normal reticuloendothelial system (RES), but are not retained in lesions lacking Kupffer cells. Consequently, there are significant differences in T2/T2* relaxation between normal tissue and lesions, resulting in increased lesion conspicuity and detectability. SPIO substantially increase the detectability of hepatic
metastases
. For focal hepatocellular lesions, SPIO-enhanced MR imaging exhibits slightly better diagnostic performance than dynamic CT. A combination of dynamic and static MR imaging technique using T1- and T2 imaging criteria appears to provide clinically more useful patterns of enhancement. Feridex and
Resovist
are also used for evaluating macrophage activities in some inflammatory lesions, but their clinical values remain to be further confirmed. The clinical development of Ferumoxtran (Combidex in the USA, Sinerem in Europe), designed for lymph node metastasis evaluation, is currently stopped.
...
PMID:Superparamagnetic iron oxide based MRI contrast agents: Current status of clinical application. 2325 52