Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: UMLS:C0024312 (lymphopenia)
4,859 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

We carried out a cross-sectional study with analysis of the demographic, clinical and laboratory characteristics of patients with metal-on-metal hip resurfacing, ceramic-on-ceramic and metal-on-polyethylene hip replacements. Our aim was to evaluate the relationship between metal-on-metal replacements, the levels of cobalt and chromium ions in whole blood and the absolute numbers of circulating lymphocytes. We recruited 164 patients (101 men and 63 women) with hip replacements, 106 with metal-on-metal hips and 58 with non-metal-on-metal hips, aged < 65 years, with a pre-operative diagnosis of osteoarthritis and no pre-existing immunological disorders. Laboratory-defined T-cell lymphopenia was present in 13 patients (15%) (CD8(+) lymphopenia) and 11 patients (13%) (CD3(+) lymphopenia) with unilateral metal-on-metal hips. There were significant differences in the absolute CD8(+) lymphocyte subset counts for the metal-on-metal groups compared with each control group (p-values ranging between 0.024 and 0.046). Statistical modelling with analysis of covariance using age, gender, type of hip replacement, smoking and circulating metal ion levels, showed that circulating levels of metal ions, especially cobalt, explained the variation in absolute lymphocyte counts for almost all lymphocyte subsets.
...
PMID:Circulating levels of cobalt and chromium from metal-on-metal hip replacement are associated with CD8+ T-cell lymphopenia. 1948 43

Characterizing wastewaters only on a chemical basis may be insufficient owing to their complex nature. The purpose of this study was to assess toxicity of textile dyeing wastewater based on analytical techniques and short term toxicity based bioassays. In this study, screening of the fractionated wastewater through GC-MS showed the presence of phenols, phthalic acid derivatives and chlorpyrifos. Metal analysis revealed that chromium, arsenic and mercury were present in amounts higher than the wastewater discharge limits. Textile dyeing wastewater was found to be highly mutagenic in the Ames test. DNA damage in sheep lymphocytes decreased linearly with an increase in the dilution of wastewater. MTT assay showed that 8.3 percent v/v wastewater decreased cell survival percentage to 50 %. It can be concluded from this study that short term toxicity tests such as Ames test, in vitro comet assay, and cytotoxicity assays may serve as useful indicators of wastewater pollution along with their organic and inorganic chemical characterizations.
...
PMID:Toxicity Appraisal of Untreated Dyeing Industry Wastewater Based on Chemical Characterization and Short Term Bioassays. 2692 Jun 97