Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Pivot Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Target Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Query: UMLS:C0024141 (
systemic lupus erythematosus
)
44,322
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
Luminol
-dependent chemiluminescence of whole blood (whole blood CL) was developed to estimate the phagocytic function of granulocytes and the serum opsonin activity simultaneously. Whole blood (0.1 ml) was examined directly and results were obtained within 20 minutes. Phagocytic function of granulocytes can be estimated from the peak CL of whole blood and the number of granulocytes in a specimen, and the opsonin activity from the amount of time the peak CL is shown after the addition of nonopsonized CL inducer (nonopsonized zymosan). Subsequently, whole blood CL was measured to evaluate phagocytic functions in children with disease. Patients with chronic granulomatous disease showed no CL, and one of their mothers (1/3) showed low CL, suggesting she is a carrier. Two patients with hypocomplementemia (
SLE
and chronic nephritis) showed low serum opsonin activity, and phagocytic function of their granulocytes was enhanced. In cord blood and newborn infants serum opsonin activity was low, and phagocytic function of granulocytes was slightly decreased in cord blood but not in newborn infants. Patients with systemic bacterial infections showed an increased phagocytic function of granulocytes. Anti-cancer drugs decreased serum opsonin activity in children with leukemia or lymphoma. The children treated with L-asparaginase had very low opsonin activity, suggesting the drug inhibits complement synthesis. The measurement of whole blood CL was useful for monitering the phagocytic functions of blood after granulocyte transfusion.
...
PMID:[Chemiluminescence of whole blood--analysis of the kinetics and application of clinical examination of phagocytic functions of whole blood from various type of diseases]. 355 74
Relationship between chemiluminescent response of whole citrate capillary blood of normal subjects, patients with osteoarthrosis deformans (n = 21) and with
systemic lupus erythematosus
(n = 37) and the temperature and duration of storage of blood samples was under study.
Luminol
-dependent chemiluminescence was induced by barium sulfate microcrystals and recorded as a curve. Chemiluminescence intensity was found to increase if the samples were stored longer than 1 h, this increase being reliably higher in the patients with
systemic lupus erythematosus
than in normal subjects or patients with osteoarthrosis. Capacity of citrate blood phagocytes to chemiluminescent response is partially preserved after 24 h storage on the cold, but is commonly manifest only after an hour's adaptation to room temperature. The following phases are characteristic of the chemiluminescent response curve in the majority of cases: latent (up to 1.5 = 4 h), an abrupt rise, and slow decrease.
...
PMID:[Effects of temperature and duration of storage of citrated blood on chemiluminescence of its phagocytes]. 789 10