Query: UMLS:C0024141 (
systemic lupus erythematosus
)
44,322
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
Lupus
anticoagulants (LA) are immunoglobulins (IgG, IgM, IgA or a mixture) which interfere with in vitro phospholipid (PL) dependent tests of coagulation (e.g. APTT, KCT, dilute Russell Viper Venom Time). LA are heterogeneous; consequently, the laboratory diagnosis is difficult and relies on multiple tests. We have developed a sensitive and relatively specific confirmatory test system based on fractions of two snake venoms. Textarin, a protein fraction of Pseudonaja textilis venom (Australian Eastern brown snake), activates prothrombin in the presence of PL, factor V and calcium ions. Ecarin, a protein fraction of Echis carinatus venom, will activate prothrombin in the absence of any cofactors. The activation of prothrombin by Textarin yields thrombin while Ecarin yields meizothrombin. In the presence of LA, the Textarin time is prolonged and the Ecarin time is unaffected. The test results are reported as a ratio of Textarin/Ecarin times (abnormal greater than 1.3). We have evaluated this test system in the following patient populations: LA positive, therapeutically heparinized, stable oral anticoagulated, liver disease, routine preoperative, anticardiolipin antibody positive LA negative, hemophilia A, various other hereditary factor deficiencies or dysfunctional proteins, and specific inhibitors of factor V and factor VIII. The LA positive patients represented a mixed population of autoimmune disease, drug-induced and post-infectious states. Our findings indicate the sensitivity of the Textarin/Ecarin system in the confirmation of LA. In order to use the test system most effectively, it is recommended to incorporate polybrene with Textarin when evaluating heparinized samples.
Factor V deficiency
and specific inhibitors of factor V yielded, in some instances, false positive results.
...
PMID:The Textarin/Ecarin ratio: a confirmatory test for lupus anticoagulants. 816 13
: Utility of coagulation analyzers in real-world settings depends on characteristics that are often not studied comprehensively. This study aimed to investigate the analytical performance, system functionality, practicability, consistency and throughput of two new automated coagulation analyzers in routine laboratory practice. Real-world settings were simulated in three major European hemostasis laboratories and multiple assays were performed in anonymized plasma samples in parallel with routine clinical practice on the cobas t 711 (high-throughput) and cobas t 511 (mid-throughput) analyzers using activated partial thromboplastin time (aPTT), aPTT
Lupus
, aPTT Screen, Antithrombin (AT), D-Dimer, Fibrinogen, Prothrombin Time (PT)-derived Fibrinogen, PT
Owren
, PT Rec (recombinant human thromboplastin reagent) and Thrombin Time assays. Precision was tested in a 21-day experiment and accuracy was compared with reference methods of the same laboratory. A number of experiments simulated challenging real-life situations. Pearson's correlation coefficient was more than 0.98 in all assays. Across assays, coefficients of variation ranged from 0.0 to 1.5% for intermediate precision; 0.2 to 3.0% for repeatability and 0.4 to 3.7% for total precision. Good between-run comparability was seen when testing samples under random conditions. Calculated maximum throughput was 197 and 387-402 tests/h for the cobas t 511 and 711 analyzers, respectively. Practicability met or exceeded user expectations in 98% of cases. In a simulated real-life setting of three major laboratories, the new cobas t 511 and cobas t 711 coagulation analyzers demonstrated a good functionality, practicability and performance and the throughput was high.
...
PMID:System performance evaluation of the cobas t 711 and cobas t 511 coagulation analyzers in routine laboratory settings. 3282 93