Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: UMLS:C0021843 (bowel obstruction)
9,927 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

Abdominal surgery is associated with a significant risk for incisional herniation. Hernia repair is routinely performed by implantation of synthetic meshes. Such meshes may cause serious adhesions between the implanted material and organs leading to intestinal obstruction or enterocutaneous fistulas. This study compares three knitted meshes for their capacity to prevent adhesion formation in an in vivo study. The meshes evaluated are polypropylene (Prolene), polypropylene coated with oxygenated regenerated cellulose-in principle-a biodegradable biomaterial (Proceed, and Prolene coated with a nondegradable copolymer of the hydrophilic building block N-vinyl pyrrolidone (NVP) and the hydrophobic building block n-butylmethacrylate (BMA). The meshes were implanted in the abdomen of rats (follow-up 7 or 30 days). After 7 days, the formation of adhesions decreased in the order: Prolene > NVP/BMA-coated Prolene > Proceed; after 30 days, this order changed into: Proceed > Prolene > NVP/BMA-coated Prolene. Both at 7 and at 30 days, Proceed was the only mesh surrounded by macrophage cells that contained foreign materials, presumably degradation products of the (biodegradable) surface coating. The data indicate that long-term protection of implanted meshes against excessive adhesions may be achieved through stable biocompatible hydrogel surface coatings.
...
PMID:Polypropylene meshes to prevent abdominal herniation. Can stable coatings prevent adhesions in the long term? 1903 65

The majority of ingested foreign bodies pass of their own accord without causing any adverse impact on the patient, while others present a greater management dilemma. We present a case of a 36-year-old man admitted to the hospital with a 10-day history of colicky abdominal pain following voluntary ingestion of multiple pairs of vinyl gloves. The plain-film abdominal X-ray confirmed small bowel obstruction and gastric bezoar. After failed conservative management he opted for endoscopic retrieval. Following exposure to stomach acid the gloves had lost their structural integrity becoming hard, sharp and brittle. As a result endoscopic removal was abandoned due to the risk of traumatic injury to the oesophagus. A midline laparotomy was performed and the gloves were retrieved via enterotomy. While many foreign bodies are suitable for endoscopic extraction this case demonstrates that the retrieval of vinyl gloves is unlikely to be successful due to significant chemical change.
...
PMID:Twenty-one bust: a case of chemical transformation of an ingested foreign body. 2433 22