Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: UMLS:C0021051 (immunodeficiency)
71,517 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

Using a quantitative suspension test method, the antiviral activity of sodium hypochlorite (NaOCl) and sodium dichloroisocyanurate (NaDCC) against human immunodeficiency virus (HIV) was investigated. Viral suspensions were prepared containing 10(4)-10(5) syncitial forming units ml-1 in 0.9% saline or 0.9% saline containing 10% v/v plasma to simulate clean and dirty conditions. A syncitial inhibition assay on C8166 lymphoblastoid line was used to determine viral titre. Results indicate that satisfactory disinfection (3-4 log reduction in 2 min) can be achieved using NaDCC and NaOCl at concentrations of 50 ppm and 2500 ppm available chlorine (AvCl2) for clean and soiled conditions respectively. For treatment of blood spillages, the addition of NaDCC and NaOCl solutions (10,000 ppm) to equal volumes of contaminated blood (giving a final AvCl2 concentration of 5000 ppm of blood) was sufficient to produce total kill within 2 min. For treatment of spillage material, chlorine-releasing powder formulations--which produce higher AVCl2 concentrations and achieve containment of spillage material--offer an effective alternative.
...
PMID:Evaluation of hypochlorite-releasing disinfectants against the human immunodeficiency virus (HIV). 197 34

In view of the selective anti-HIV activity of 2',3'-dideoxy-3'-fluoro-5-chlorouridine (11), a series of eight 2',3'-dideoxy-5-chloropyrimidines were synthesized and evaluated for their inhibitory activity against human immunodeficiency virus type 1 (HIV-1) replication in MT-4 cells. A marked improvement in selectivity was noted for the 5-chlorouracil derivatives of 2,3-dideoxyribofuranose, 3-azido-2,3-dideoxyribofuranose, and 3-fluoro-2,3-dideoxyribofuranose, mainly due to decreased toxicity of the compounds for the host cells. While chlorination of 2',3'-dideoxycytidine removed the anti-HIV activity, introduction of a chlorine at the C-5 position of 3'-fluoro-, 3'-azido- or 2',3'-didehydro-2',3'-dideoxycytidine led to reduced cytotoxicity with only slightly reduced anti-HIV activity. X-ray analysis showed compound 11 to have two molecules in the asymmetric unit with chi = -168.8 (3) degrees and -131.3 (3) degrees and P = 179 (1) degree and 163 (1) degree, respectively; thus revealing no close resemblance to 3'-azido-3'-deoxythymidine (AZT).
...
PMID:Synthesis and anti-HIV evaluation of 2',3'-dideoxyribo-5-chloropyrimidine analogues: reduced toxicity of 5-chlorinated 2',3'-dideoxynucleosides. 234 78

Halogenated gomisin J (a derivative of lignan compound), represented by the bromine derivative 1506 [(6R, 7S, S-biar)-4,9-dibromo-3,10-dihydroxy-1,2,11,12-tetramethoxy-6, 7-dimethyl-5,6,7,8- tetrahydrodibenzo[a,c]cyclo-octene], was found to be a potent inhibitor of the cytopathic effects of human immunodeficiency virus type 1 (HIV-1) on MT-4 human T cells (50% effective dose, 0.1 to 0.5 microM). Gomisin J derivatives were active in preventing p24 production from acutely HIV-1-infected H9 cells. The selective indices (toxic dose/effective dose) of these compounds were as high as > 300 in some systems. 1506 was active against 3'-azido-3'-deoxythymidine-resistant HIV-1 and acted synergistically with AZT and 2',3'-ddC. 1506 inhibited HIV-1 reverse transcriptase (RT) in vitro but not HIV-1 protease. From the time-of-addition experiment, 1506 was found to inhibit the early phase of the HIV life cycle. A 1506-resistant HIV mutant was selected and shown to possess a mutation within the RT-coding region (at position 188 [Tyr to Leu]). The mutant RT expressed in Escherichia coli was resistant to 1506 in the in vitro RT assay. Some of the HIV strains resistant to other nonnucleoside HIV-1 RT inhibitors were also resistant to 1506. Comparison of various gomisin J derivatives with gomisin J showed that iodine, bromine, and chlorine in the fourth and ninth positions increased RT inhibitory activity as well as cytoprotective activity.
...
PMID:Anti-human immunodeficiency virus (HIV) activities of halogenated gomisin J derivatives, new nonnucleoside inhibitors of HIV type 1 reverse transcriptase. 854 Jul 6

The efficacy of sodium hypochlorite was assessed against human immunodeficiency virus type 1 suspended in low (8% v/v) or high (80% v/v) concentrations of serum or in a high (80%) concentration of blood. In the presence of 8% serum, 100 p.p.m. available chlorine in the disinfectant test mixture inactivated 3.75 log TCID50 HIV/ml within 30 s. When the test mixture contained 80% serum, 500 p.p.m. available chlorine inactivated more than 4 log TCID50 HIV/ml in 1-2 min. Lower concentrations of available chlorine were unable to inactivate the virus completely. In the presence of 80% blood, 1000 p.p.m. available chlorine in the disinfectant test mixture was unable to inactivate 3.75 log TCID50 HIV/ml, although 2500 p.p.m. available chlorine was able to inactivate at least 1.5 log TCID50 HIV/ml. In all test mixtures, the chlorine rapidly became combined and thus less active. Our results emphasise the importance of cleaning prior to disinfection with sodium hypochlorite since it may prove to be ineffective in the presence of high levels of organic matter. In cases where prior cleaning is impossible, care must be taken to use the higher recommended concentration (a minimum of 10,000 p.p.m. available chlorine).
...
PMID:Inactivation of HIV-1 by chemical disinfectants: sodium hypochlorite. 855 89

The antiviral activities of sodium dichloroisocyanurate (NaDCC) and a commercial product (Solprogel 2%) against human immunodeficiency virus type 1 (HIV-1) were investigated using a quantitative suspension test method. Solprogel is a compound that contains NaDCC and a biodegradable polymer of acrylic acid. Viral suspensions were prepared containing 3.2 x 10(6) tissue culture infective dose 50 (TCID50) in culture media. Syncytium formation in the MT-2 line and HIV antigen p24 on the supernatant of the cultures were used to determine viral titre. Results indicate that satisfactory disinfection (1000-fold reduction in 5 min) can be achieved using NaDCC and Solprogel at concentrations of 100 and 120 ppm available chlorine, respectively.
...
PMID:Evaluation of the disinfectant effect of Solprogel against human immunodeficiency virus type 1 (HIV-1). 892 78

The susceptibility of Mycobacterium tuberculosis and Mycobacterium avium-intracellulare to the disinfections used for spillage and heat sensitive instruments has received much attention in recent years. The use of clinical isolates of M. tuberculosis and M. avium-intracellulare as test organisms is considered unsuitable for standard tests due to their hazardous nature (category 3 pathogens and slow growth rates). This has led to much debate in standards committees on the selection and use of a possible surrogate which would be safer and more practical to use and yet mimic the susceptibility of clinical isolates. This study compared the susceptibility of one possible surrogate Mycobacterium terrae NCTC 10856, with that of clinical isolates of M. tuberculosis H37 Rv and M. avium-intracellulare using a quantitative suspension test. The instrument and environmental disinfectants tested were a chlorine-releasing agent, sodium dichloroisocyanyurate (NaDCC) at 1000 ppm and 10,000 ppm av. Cl, chlorine dioxide at 1100 ppm av. ClO2 (Tristel, HayMan MediChem), 0.35% peracetic acid (NuCidex, Johnson & Johnson), 70% industrial methylated spirit (IMS), 2% alkaline glutaraldehyde (Asep, Galen), 10% succine dialdehyde and formaldehyde mixture (Gigasept, Schulke and Mayr). Results showed that the clinical isolate of M. avium-intracellulare was the most resistant of the three test organisms. M. terrae, which is not a category 3 pathogen, was slightly more resistant than M. tuberculosis and this would appear to be a suitable surrogate for establishing tuberculocidal activity. However, with an increase in the clinical significance of M. avium-intracellulare, particularly in human immunodeficiency virus (HIV) and immunocompromised patients, a more resistant surrogate is required. In the absence of such a surrogate, testing with M. avium-intracellulare in a clinical laboratory equipped for handling category 3 pathogens is still advised to establish mycobactericidal activity.
...
PMID:Mycobacterium terrae: a potential surrogate for Mycobacterium tuberculosis in a standard disinfectant test. 956 69

Two per cent glutaraldehyde is the most commonly used disinfectant in endoscopy units within the UK. Unfortunately adverse reactions to glutaraldehyde are common among endoscopy personnel and the Health and Safety Commission has recommended substantial reductions in atmospheric levels of glutaraldehyde in order to comply with the Control of Substances Hazardous to Health Regulations, 1994. The Working Party addressed ways of eliminating or minimising exposure to glutaraldehyde in endoscopy units by reviewing alternative disinfectants and the use of automated washer/disinfectors. Alternatives to glutaraldehyde must be at least as microbicidal as glutaraldehyde, non-irritating and compatible with endoscope components and decontamination equipment. Peracetic acid is a highly effective disinfectant and may be a suitable alternative to glutaraldehyde. Peracetic acid has a vinegary-like odour and is claimed to be less irritating than glutaraldehyde. Experience with this agent remains relatively limited and the Working Party recommends that peracetic acid should be used in sealed or exhaust ventilated facilities until further experience is obtained. It is considerably more expensive than glutaraldehyde, is less stable and large volumes have to be stored. It causes cosmetic (but not functional) damage to endoscopes and is not compatible with some washer/ disinfectors. Chlorine dioxide is a powerful oxidising agent and highly effective as a disinfectant. Once activated it must be stored in sealed containers with little head space. Fumes cause irritation and sealed or exhaust ventilated facilities are necessary. The agent may damage some metallic and polymer components of endoscopes and automated washer/disinfectors and compatibility should be established with equipment manufacturers before the agent is used. Other disinfectants such as peroxygen compounds and quaternary ammonium derivatives are less suitable because of unsatisfactory mycobactericidal and/or virucidal activity, or incompatibility with endoscopes and automated washer/disinfectors. Alcohol is effective but, on prolonged contact, is damaging to lens cements. It is also flammable and therefore unsuitable for use in large quantities in automated systems. Superoxidised water (Sterilox) is an electrochemical solution (anolyte) containing a mixture of radicals with strong oxidising properties. It is highly microbicidal when freshly generated, provided items are thoroughly clean and strict generation criteria are met--that is, current, pH, redox potential. It seems to be safe for users and provided field trials substantiate laboratory efficacy tests, and the agent is non-damaging, it too may become an alternative to glutaraldehyde. When 2% glutaraldehyde is used for manual and automated disinfection, 10 minutes' immersion is recommended for endoscopes before the session and between patients. This will destroy vegetative bacteria and viruses (including hepatitis B virus (HBV) and HIV). A five minute contact period is recommended for 0.35% peracetic acid and for chlorine dioxide (1100 ppm av ClO2), but if immersed for 10 minutes sporicidal activity will also be achieved. At the end of each session 20 minutes' immersion in glutaraldehyde or five minutes in peracetic acid or chlorine dioxide is recommended. Microbiological studies show that 20 minutes of exposure to 2% glutaraldehyde destroys most organisms, including Mycobacterium tuberculosis. The Working Party concludes therefore that immersion of the endoscope in 2% glutaraldehyde for 20 minutes is sufficient for endoscopy involving patients with AIDS and other immunodeficiency states or pulmonary tuberculosis. Similarly, 20 minutes' immersion is recommended at the start of the list and between cases for endoscopic retrograde cholangiopancreatography (ERCP) when high level disinfection is required. Cleaning and disinfection of endoscopes should be undertaken by trained staff in a dedicated room. Thorough cleaning with detergent
...
PMID:Cleaning and disinfection of equipment for gastrointestinal endoscopy. Report of a Working Party of the British Society of Gastroenterology Endoscopy Committee. 961 26

We synthesized and tested as novel inhibitors of human immunodeficiency virus type 1 (HIV-1) bi- and tricyclic thiadiazine ring homologues of 7-chloro-2-ethyl-2H-1,2,4-benzothiadiazin-3-(4H)-one 1,1-dioxide, which is a compound endowed with anti-HIV-1 activity at low micromolar concentrations. Benzothiadiazepine derivatives were obtained by alkylation of 8-chloro-2,3-dihydro-3-methyl-1,2,5-benzothiadiazepin-4(5H)-one 1,1-dioxide, which was obtained by intramolecular cyclization of 2-(2-amino-5-chloro-benzenesulphonamido) propanoic acid. Pyrrolobenzothiadiazepines were synthesized from N-substituted 5-chloro-2-(1H-pyrrol-1-yl)benzene-sulphonamides by treating with triphosgene. N6-substituted pyrrolo[2,1-d][1,2,5]benzothiazepin-7(6H)-one 5,5-dioxides were active, though not very potent. Both a chlorine atom and an unsaturated alkyl chain were found to be determinants of anti-HIV-1 activity. The highest potency was shown by a derivative with a TIBO-related 3,3-dimethylallyl chain. 2,3-Dihydro-1,2,5-benzothiadiazepin-4(5H)-one 1,1-dioxides were scarcely active in HIV-1-infected MT-4 cell assays; however, the introduction of the dimethylallyl chain into 7-chloro-1,2,5-benzothiadiazepine moiety led to a bicyclic derivative which was more potent and less cytotoxic than the tricyclic pyrrole-containing counterpart.
...
PMID:1,2,5-Benzothiadiazepine and pyrrolo[2,1-d]-[1,2,5]benzothiadiazepine derivatives with specific anti-human immunodeficiency virus type 1 activity. 987 84

Electrolyzed products of sodium chloride solution were examined for their disinfection potential against hepatitis B virus (HBV) and human immunodeficiency virus (HIV) in vitro. Electrolysis of 0.05% NaCl in tap water was carried out for 45 min at room temperature using a 3 A electric current in separate wells installed with positive and negative electrodes. The electrolyzed products were obtained from the positive well. The oxidation reduction potential (ORP), pH and free chlorine content of the product were 1053 mV, pH 2.34 and 4.20 ppm, respectively. The products modified the antigenicity of the surface protein of HBV as well as the infectivity of HIV in time- and concentration-dependent manner. Although the inactivating potential was decreased by the addition of contaminating protein, recycling of the product or continuous addition of fresh product may restore the complete disinfection against bloodborne pathogens.
...
PMID:Disinfection potential of electrolyzed solutions containing sodium chloride at low concentrations. 1071 49

Dioxins and dioxin-like substances are highly toxic and extremely dangerous chemical compounds. Dioxins are formed during the thermal process associated with the use of chlorine. 2,3,7,8-tetrachlorodibenzo-1,4-dioxin is the most toxic, the most typical and well-studied agent. The most characteristic and constant indicators of intoxication with dioxin-containing substances are altered body weight, chloracne, hepatic damage, thyroid involution, structural changes in the adrenal cortex, spleen, genitals, immunodeficiency. There is evidence for a role of these agents in the development of infertility and neonatal pathology.
...
PMID:[Dioxins: facts and conjectures]. 1238 Feb 82


1 2 Next >>