Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: UMLS:C0021051 (immunodeficiency)
71,517 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

Nevirapine (VIRAMUNE) is a non-nucleoside reverse transcriptase inhibitor with activity against human immunodeficiency virus type 1 (HIV-1), currently marketed for the treatment of HIV-1 infected adults. A reverse phase HPLC-UV method was optimized and validated for the determination of nevirapine in human plasma, serum, milk and cerebrospinal fluid. The analyte was extracted from 250 microl of biofluid using a bonded silica solid phase extraction column, and resolved chromatographically on a reversed-phase, 15x0.46 cm i.d. 5 microm particle Supelco LC-8 analytical column with an isocratic mobile phase of 63% phosphate buffer (0.025 M, pH 6.0) with 1-butanesulfonic acid as anion-pair reagent: 21.5% methanol: 15.5% acetonitrile. The peaks were detected at a flow rate of 1.0 ml min(-1), at a wavelength of 280 nm, with a run time of 10 min. The assay was linear over a range of 25 to 10000 ng ml(-1). This method has been used for the clinical development of nevirapine.
...
PMID:HPLC-UV method for the quantitation of nevirapine in biological matrices following solid phase extraction. 1070 12

3'-Azido-2',3'-dideoxyuridine (AZDU, Azddu, CS-87) is a nucleoside analog of 3'-azido-3'-deoxythymidine (zidovudine, AZT) that has been shown to inhibit human immunodeficiency virus (HIV-1). AZDU is a potential candidate for treatment of pregnant mothers to prevent prenatal transmission of HIV/AIDS to their unborn children. A rapid and efficient high-performance liquid chromatography (HPLC) method for the determination of AZDU concentrations in rat maternal plasma, amniotic fluid, placental and fetal tissue samples has been developed and validated. Tissue samples were homogenized in distilled water, protein precipitated and extracted using a C-18 solid-phase extraction (SPE) method prior to analysis. Plasma and amniotic fluid samples were protein precipitated with 2 M perchloric acid prior to analysis. Baseline resolution was achieved using a 4.5% acetonitrile in 40 mM sodium acetate (pH 7) buffer mobile phase for amniotic fluid, placenta and fetus samples and with a 5.5% acetonitrile in buffer solution for plasma at flow-rates of 2.0 ml/min. The HPLC system consists of a Hypersil ODS column (150x4.6 mm) with a Nova-Pak C-18 guard column with detection at 263 nm. The method yields retention times of 6.2 and 12.2 min for AZDU and AZT in plasma and 8.3 and 17.6 min for AZDU and AZT in amniotic fluid, fetal and placental tissues. Limits of detection ranged from 0.01 to 0.075 microg/ml. Recoveries ranged from 81 to 96% for AZDU and from 82 to 96% for AZT in the different matrices. Intra-day (n=6) and inter-day (n=9) precision (% RSD) and accuracy (% Error) ranged from 1.48 to 6.25% and from 0.50 to 10.07%, respectively.
...
PMID:Determination of 3'-azido-2',3'-dideoxyuridine in maternal plasma, amniotic fluid, fetal and placental tissues by high-performance liquid chromatography. 1139 1

The natural form of the human immunodeficiency virus type one reverse transcriptase (HIV-1 RT) found in virion particles is a heterodimer composed of the p66 and p51 subunits. The catalytic activity resides in the larger subunit in the heterodimeric (p66/p51) enzyme while in the monomeric form it is inactive. In contrast, Murine leukemia virus RT (MuLV RT) is functionally active in the monomeric form. In the primary amino acid sequence alignment of MuLV RT and HIV-1 RT, we have identified three specific regions in MuLV RT, that were missing in HIV-1 RT. In a separate study, we have shown that a chimeric RT construct comprising of the polymerase domain of HIV-1 RT and RNase-H domain of MuLV RT is functionally active as monomer [20]. In this communication, we demonstrate that insertion of a peptide (corresponding to amino acid residues 480-506) from the connection subdomain of MuLV RT into the connection subdomain of HIV-1 RT (between residues 429 and 430) results in a functionally active monomeric chimeric RT. Furthermore, this chimeric enzyme does not dimerize with exogenously added p51 subunit of HIV-1RT. Functional analysis of the chimeric RT revealed template specific variations in its catalytic activity. The chimeric enzyme catalyzes DNA synthesis on both heteropolymeric DNA and homopolymeric RNA (poly rA) template but curiously lacks reverse transcriptase ability on heteropolymeric RNA template. Similar to MuLV RT, the polymerase activity of the chimeric enzyme is not affected by acetonitrile, a reagent which dissociates dimeric HIV-1 RT into inactive monomers. These results together with a proposed 3-D molecular model of the chimeric enzyme suggests that the insertion of the missing region may induce a change in the spatial position of RNase H domain such that it is functionally active in monomeric conformation.
...
PMID:Insertion of a peptide from MuLV RT into the connection subdomain of HIV-1 RT results in a functionally active chimeric enzyme in monomeric conformation. 1171 55

As part of our on-going study of the analysis of anti-human immunodeficiency virus (HIV) nucleosides, a capillary electrochromatography (CEC) method has been developed for the concurrent analysis of nucleoside HIV reverse transcriptase inhibitors (NRTIs) in a pool of endogenous nucleosides. Up to now, beta-cyclodextrin-bonded silica stationary phases have mainly been dedicated to the separation of enantiomers; however, these polysaccharides can be also be used in achiral way. This work aims at showing how CEC performed on a beta-cyclodextrin-bonded silica stationary phase can be used to concurrently resolve zidovudine (AZT), lamivudine (3TC), didanosine (ddA) and its administrated form (ddI), stavudine (d4T) and hivid (ddC) in a mixture of adenosine (A), cytidine (C), guanosine (G), thymidine (T) and uridine (U). The influence of several parameters (pH buffer, ionic strength, acetonitrile content, temperature and voltage) on both the retention times and the retention factors has been investigated using the short-end injection technique to achieve baseline separation in a short-time analysis before quantitation. Moreover, the retention factors of the charged solutes in short-end injection-CEC were calculated using theoretically derived equations, allowing for the actual voltage drop in the packed section of the semipacked CEC capillary.
...
PMID:Concurrent analysis of nucleoside reverse transcriptase inhibitors in a pool of endogenous nucleosides by short-end injection-capillary electrochromatography on a beta-cyclodextrin-bonded stationary phase. 1200 25

A selective and sensitive high-performance liquid chromatographic (HPLC) method has been developed for the determination of the six human immunodeficiency virus (HIV)-protease inhibitors (amprenavir, indinavir, lopinavir, nelfinavir, ritonavir, and saquinavir) and the non-nucleoside reverse transcriptase inhibitors (efavirenz and nevirapine) in a single run. After a liquid-liquid extraction with diethyl ether, the six protease inhibitors and the two non-nucleoside reverse transcriptase inhibitors are separated on a Stability RP18 column eluted with a gradient of acetonitrile and phosphate buffer 50 mmol/L pH 5.65. A sequential ultraviolet detection (5-minute sequence set at 240 nm for nevirapine acquisition, 22-minute sequence set at 215 nm for other antiretroviral drugs acquisition followed by a sequence set at 260 nm for internal standard acquisition) allowed for simultaneous quantitation of the six protease inhibitors, nevirapine, and efavirenz. Calibration curves were linear in the range 100 ng/mL to 10,000 ng/mL. The limit of quantitation was 50 ng/mL for all drugs except nevirapine (100 ng/mL). Average accuracy at four concentrations ranged from 88.2% to 110.9%. Both interday and intraday coefficients of variation were less than 11% for all drugs. The extraction recoveries were greater than 62%. This method is simple and shows a good specificity with respect to commonly co-prescribed drugs. This method allows accurate therapeutic monitoring of amprenavir, indinavir, lopinavir, nelfinavir, ritonavir, saquinavir, efavirenz, and nevirapine.
...
PMID:High-performance liquid chromatographic method for the simultaneous determination of the six HIV-protease inhibitors and two non-nucleoside reverse transcriptase inhibitors in human plasma. 1202 35

An isocratic reversed-phase high-performance liquid chromatographic method with ultraviolet detection at 205 nm has been validated for the determination of indinavir, ritonavir and lopinavir (ABT 378) in human plasma. The ritonavir analogue A-86093.0 was used as internal standard. Good chromatographic separation was achieved using a stainless steel column packed with 5 microm Phenomenex phenyl hexyl material operated at 40 degrees C, and a mobile phase consisting of acetonitrile-10 mM potassium phosphate buffer (50:50, v/v). The calibration curve for indinavir was linear over the range of 50 to 1000 microg/l while the ritonavir and lopinavir calibration curves were linear over the range of 100 to 15,000 microg/l. The lower limit of quantitations for indinavir, ritonavir and lopinavir were 50, 100 and 100 microg/l, respectively, using 500 microl of human plasma. The validation data showed that the assay is sensitive, specific and reproducible for determination of indinavir, ritonavir and lopinavir. This method is being used in a therapeutic drug monitoring service to quantitate these therapeutic agents in patients infected with human immunodeficiency virus.
...
PMID:Simultaneous determination of indinavir, ritonavir and lopinavir (ABT 378) in human plasma by high-performance liquid chromatography. 1211 89

Syntheses of [carbonyl-11C]2-(2-benzoylphenoxy)-N-phenylacetamide, a radiolabeled inhibitor of human immunodeficiency virus type 1 (HIV 1) reverse transcriptase, were achieved by applying palladium-mediated cross-coupling reactions with insertion of [11C]carbon monoxide. Our interest was focused for the present on a comparison of the Stille and Suzuki methods, using trimethylphenylstannane or phenylboronic acid as alternative coupling reagents, respectively. The Suzuki variant gave a much higher amount of [11C]CO radioactivity trapped in the reaction mixture, but a significant loss of product occurred due to adsorption phenomena on the potassium carbonate present in the heterogeneous reaction mixture. The labeled product was isolated in only 20% yield (based on trapped [11C]CO, not corrected for decay). According to Stille, the reaction provided a product that could be isolated more easily but it did not increase the final yield of the target compound due to a low trapping efficiency for [11C]CO. Both methods were performed in an overall synthesis time of 30min, starting from [11C]CO2, and gave a product with a specific radioactivity of at least 30GBq/micromol. The Stille method as well as the Suzuki reaction allowed the synthesis of a radiochemically pure product in aqueous acetonitrile.
...
PMID:Syntheses of [carbonyl-11C]2-(2-benzoylphenoxy)-N-phenylacetamide from [11C]carbon monoxide by the Suzuki and the Stille reactions. 1243 42

A series of novel 10-thiaisoalloxazine derivatives bearing an alkoxymethyl or benzyloxymethyl moiety at the N-1 position has been synthesized through the bromination of 1-substituted-5-hydroxyuracils and subsequent condensation with aminobenzenethiol in a one-pot reaction. Contrary to the previous report, the formation of intermediary 5,6-diethoxy-5-hydroxy-5,6-dihydrouracil seems to be not the necessary factor for the formation of the thiaisoalloxazines, since the reaction proceeds in tetrahydrofuran (THF) or acetonitrile far more smoothly than in ethanol. The anti-human immunodeficiency virus (HIV)-1 activity of the resulted thiaisoalloxazine derivatives was evaluated in lymphocyte cells based on the inhibitory activity against the viral-induced cytopathic activity. Among the derivatives, compounds 6, 7, and 8 bearing an alkoxymethyl moiety at the N-1 position exhibited modest inhibitory activity towards the cytotopathic effect of HIV-1.
...
PMID:Synthesis and anti-HIV-1 activity of novel 10-thiaisoalloxazines, a structural analog of C-5 and/or C-6 substituted pyrimidine acyclonucleoside. 1280 37

3'-Azido-2',3'-dideoxyuridine (AZDU) is a nucleoside analog structurally similar to zidovudine (AZT) with proven activity against human immunodeficiency virus (HIV). The purpose of this study was to develop and validate a high-performance liquid chromatographic (HPLC) method to quantitatively determine AZDU and its novel prodrugs in rat plasma simultaneously. A reversed-phase gradient elution HPLC method was developed to quantitate AZDU and its prodrugs, N3-pivaloyloxymethyl-3'-azido-2',3'-dideoxyuridine (I), 5'-pivaloyloxymethyl-3'-azido-2',3'-dideoxyuridine (II), 5'-O-valinyl-3'-azido-2',3'-dideoxyuridine hydrochloride (III) and 5'-O-phenylalanyl-3'-azido-2',3'-dideoxyuridine hydrochloride (IV), in rat plasma. AZDU and its prodrugs were analyzed using an octadecyl silane column with a mobile phase consisting of 0.04 microM sodium acetate buffer, pH 5.0, and acetonitrile, running in a segmented gradient manner at a flow rate of 2 ml/min. Acetonitrile was increased from 10 to 50% during the first 8 min by 5% per min, followed by 10% per min until it reached 90% acetonitrile. 3'-Azido-2',3'-dideoxy-5-ethyluridine (CS-85) was used as an internal standard (25 microg/ml). Compounds were detected by UV absorption at 261 nm. Extraction recoveries for all compounds were greater than 80%. Retention times of AZDU, CS-85, prodrugs I, II, III and IV were 3.3, 5.2, 9.1, 8.8, 6.3 and 7.3 min, respectively. Calibration plots were linear over the range of 0.25-100 microg/ml for AZDU and prodrugs II, III, and IV and 0.5-100 microg/ml for prodrug I. The limit of quantitation was 0.25 microg/ml for prodrugs II, III and IV and 0.5 microg/ml for prodrug I. The intra- and inter-day variations were less than 10% and accuracies were greater than 90%. This method is rapid, sensitive and reproducible for the determination of AZDU and prodrugs in rat plasma.
...
PMID:Simultaneous determination of 3'-azido-2',3'-dideoxyuridine and novel prodrugs in rat plasma by liquid chromatography. 1452 42

Zidovudine (AZT) therapy given during pregnancy has been shown to reduce the vertical transmission of the human immunodeficiency virus (HIV) from mother to fetus. In order to investigate the efficacy of AZT, it is important to know the concentration of its active phosphorylated metabolites. We have developed the first CE method for the simultaneous quantitation of AZT and zidovudine monophosphate (AZT-MP) from rat plasma, amniotic fluid and fetal tissues. Sample extractions were performed by protein precipitation using acetonitrile for the plasma and amniotic fluids, while in fetal tissues solid phase extraction using Waters Oasis HLB extraction cartridges was used. Recoveries ranged from 78 to 92% for AZT, AZT-MP and 3'-azidouridine (internal standard, AZDU), in the three matrices. The optimum separation conditions were achieved using a 40 mm sodium dodecylsulfate (SDS) in 50 mm phosphate buffer (pH 7) with a run voltage of 15 kV. The CE system consists of a 75 microm i.d., 50 cm effective length uncoated fused silica capillary. The method was validated over the range 0.5-100 microg/ml ( micro g/g for tissues). Intra-day precision (RSD) and accuracy (%error) for AZT ranged from 0.13 to 11 and 0.68 to 11.1%, respectively, while for AZT-MP it ranged from 2.05 to 11.1 and 4.22 to 11.7%. Inter-day precision and accuracy for AZT ranged from 3.82 to 11.2 and 3.14 to 9.01%, while for AZT-MP it ranged from 3.9 to 9.32 and 3.44 to 9.37%, respectively. We also report the enzymatic dephosphorylation of AZT-MP in the placental tissue of rats. This new enzymatic pathway provides increased understanding of the mechanism of anti-viral transport in the rat during pregnancy.
...
PMID:Simultaneous quantitation of zidovudine and zidovudine monophosphate from plasma, amniotic fluid and tissues by micellar capillary electrophoresis. 1538 21


<< Previous 1 2 3 4 5 Next >>