Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Pivot Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Target Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Query: UMLS:C0021051 (
immunodeficiency
)
71,517
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
Three procedures for the quantification of human
immunodeficiency
virus type 1 (HIV-1) RNA from plasma were compared at three laboratories. The comparison involved the Quantiplex branched DNA assay (
version 1
.0) by Chiron Diagnostics, the NASBA-QT assay by Organon Teknika, and the Amplicor Monitor assay by Roche Molecular Systems. The laboratories performed each of the three assays with the same sets of reconstructed HIV-1-infected human plasma samples, cross-sectionally collected clinical plasma samples and longitudinally collected plasma samples from patients starting zidovudine therapy. Analysis of the reconstruction panel results for interlaboratory variation demonstrated that no laboratory differences in results were detected for any of the assays. A comparison of the reproducibilities of duplicate samples analyzed by batch and in separate assay runs demonstrated that the reproducibilities of the test results were similar within one assay and appeared to be independent of the HIV-1 concentration. The best reproducibility was obtained with the Quantiplex assay, but all three assays demonstrated equal reliability, which was independent of batched or unbatched analysis of replicate samples. Differences in the absolute concentrations calculated were observed for the assays, in particular in the analysis of reconstructed samples. In all assays, similar changes in plasma HIV-1 RNA concentrations were determined for longitudinally collected clinical samples.
...
PMID:Multicenter comparison of three commercial methods for quantification of human immunodeficiency virus type 1 RNA in plasma. 894 Apr 41
Three versions of a commercial human
immunodeficiency
virus (HIV) type 1 (HIV-1) load test (the AMPLICOR HIV-1 MONITOR Test versions 1. 0, 1.0+, and 1.5; Roche Diagnostics, Branchburg, N.J.) were evaluated for their ability to detect and quantify HIV-1 RNA of different genetic subtypes. Plasma samples from 96 patients infected with various subtypes of HIV-1 (55 patients infected with subtype A, 9 with subtype B, 21 with subtype C, 2 with subtype D, 7 with subtype E, and 2 with subtype G) and cultured virus from 29 HIV-1 reference strains (3 of subtype A, 6 of subtype B, 5 of subtype C, 3 of subtype D, 8 of subtype E, 3 of subtype F, and 1 of subtype G) were tested. Detection of subtypes A and E was significantly improved with versions 1.0+ and 1.5 compared to that with
version 1
. 0, whereas detection of subtypes B, C, D, and G was equivalent with the three versions. Versions 1.0, 1.0+, and 1.5 detected 65, 98, and 100% of the subtype A-infected samples from patients, respectively, and 71, 100, and 100% of the subtype E-infected samples from patients, respectively. Version 1.5 yielded a significant increase in viral load for samples infected with subtypes A and E (greater than 1 log10 HIV RNA copies/ml). For samples infected with subtype B, C, and D and tested with
version 1
.5, only a slight increase in viral load was observed (<0.5 log10). We also evaluated a prototype automated version of the test that uses the same PCR primers as
version 1
.5. The results with the prototype automated test were highly correlated with those of the
version 1
.5 test for all subtypes, but were lower overall. The AMPLICOR HIV-1 MONITOR Test,
version 1
.5, yielded accurate measurement of the HIV load for all HIV-1 subtypes tested, which should allow the test to be used to assess disease prognosis and response to antiretroviral treatment in patients infected with a group M HIV-1 subtype.
...
PMID:Efficiencies of four versions of the AMPLICOR HIV-1 MONITOR test for quantification of different subtypes of human immunodeficiency virus type 1. 985 73
Accurate determination of plasma human
immunodeficiency
virus type 1 (HIV-1) RNA levels is critical for the effective management of HIV-1 disease. The AMPLICOR HIV-1 MONITOR Test, a reverse transcription-PCR-based test for quantification of HIV-1 RNA in plasma, was developed when little sequence information on HIV-1 isolates from outside North America was available. It has since become apparent that many non-subtype B isolates, particularly subtypes A and E, are detected inefficiently by the test. We describe here the AMPLICOR HIV-1 MONITOR Test,
version 1
.5, an upgraded test developed to minimize subtype-related variation. We also developed a panel of HIV-1 standards containing 30 HIV-1 isolates of subtypes A through G. The virus particle concentration of each cultured viral stock was standardized by electron microscopic virus particle counting. We used this panel to determine the performance of the original AMPLICOR HIV-1 MONITOR Test and
version 1
.5 of the test with HIV-1 subtypes A through G. The original test underestimated the concentration of HIV-1 subtype A, E, F, and G RNA by 10-fold or more, whereas version of the 1.5 test yielded equivalent quantification of HIV-1 RNA regardless of the subtype. In light of the increasing intermixing of HIV-1 subtypes worldwide, standardization of PCR-based tests against well-characterized viral isolates representing the full range of HIV-1 diversity will be essential for the continued utility of these important clinical management tools.
...
PMID:Development of calibrated viral load standards for group M subtypes of human immunodeficiency virus type 1 and performance of an improved AMPLICOR HIV-1 MONITOR test with isolates of diverse subtypes. 1040 1
Quantification of human
immunodeficiency
virus type 1 (HIV-1) RNA as a measure of viral load has greatly improved the monitoring of therapies for infected individuals. With the significant reductions in viral load now observed in individuals treated with highly active anti-retroviral therapy (HAART), viral load assays have been adapted to achieve greater sensitivity. Two commercially available ultrasensitive assays, the Bayer Quantiplex HIV-1 bDNA version 3.0 (bDNA 3.0) assay and the Roche Amplicor HIV-1 Monitor Ultrasensitive
version 1
.5 (Amplicor 1.5) assay, are now being used to monitor HIV-1-infected individuals. Both of these ultrasensitive assays have a reported lower limit of 50 HIV-1 RNA copies/ml and were developed from corresponding older generation assays with lower limits of 400 to 500 copies/ml. However, the comparability of viral load data generated by these ultrasensitive assays and the relative costs of labor, disposables, and biohazardous wastes were not determined in most cases. In this study, we used matched clinical plasma samples to compare the quantification of the newer bDNA 3.0 assay with that of the older bDNA 2.0 assay and to compare the quantification and costs of the bDNA 3.0 assay and the Amplicor 1.5 assay. We found that quantification by the bDNA 3.0 assay was approximately twofold higher than that by the bDNA 2.0 assay and was highly correlated to that by the Amplicor 1.5 assay. Moreover, cost analysis based on labor, disposables, and biohazardous wastes showed significant savings with the bDNA 3.0 assay as compared to the costs of the Amplicor 1.5 assay.
...
PMID:Quantitative and cost comparison of ultrasensitive human immunodeficiency virus type 1 RNA viral load assays: Bayer bDNA quantiplex versions 3.0 and 2.0 and Roche PCR Amplicor monitor version 1.5. 1069 5
Accurate and sensitive quantification of human
immunodeficiency
virus type 1 (HIV-1) RNA has been invaluable as a marker for disease prognosis and for clinical monitoring of HIV-1 disease. The first generation of commercially available HIV-1 RNA tests were optimized to detect the predominant HIV-1 subtype found in North America and Europe, subtype B. However, these tests are frequently suboptimal in detecting HIV-1 genetic forms or subtypes found in other parts of the world. The goal of the present study was to evaluate the performance of a new viral load assay with non-subtype B viruses. A transcription-mediated amplification method for detection and quantitation of diverse HIV-1 subtypes, called the Gen-Probe HIV-1 viral load assay, is under development. In this study we examined the performance of the Gen-Probe HIV-1 viral load assay relative to that of the commonly used commercial HIV-1 RNA assays using a panel of primary isolates from Kenya. For comparison, we included several subtype B cloned viruses, and we quantified each virus using an in-house quantitative-competitive reverse transcriptase PCR (QC-RT-PCR) method and gag(p24) antigen capture. The Gen-Probe HIV-1 viral load assay and a version of the Roche AMPLICOR HIV-1 MONITOR test (
version 1
.5) that was designed to detect a broader range of subtypes were both sensitive for the quantification of Kenyan primary isolates, which represented subtype A, C, and D viruses. The Gen-Probe HIV-1 viral load assay was more sensitive for the majority of viruses than the Roche AMPLICOR HIV-1 MONITOR test
version 1
.0, the Bayer Quantiplex HIV RNA 3.0 assay, or a QC-RT-PCR method in use in our laboratory, suggesting that it provides a useful method for quantifying HIV-1 RNAs from diverse parts of the world, including Africa.
...
PMID:Evaluation of performance of the Gen-Probe human immunodeficiency virus type 1 viral load assay using primary subtype A, C, and D isolates from Kenya. 1087 65
Although human
immunodeficiency
virus type 1 (HIV-1) infection in the United States has predominantly involved subtype B, increasing global travel is leading to wider dissemination of genetically heterogeneous subtypes. While physicians depend on HIV-1 viral load measurements to guide antiretroviral therapy, commonly used molecular assays may underestimate the viral load of patients with non-B subtypes. Nine patients with non-B subtypes of HIV-1 were identified by physicians who suspected a non-B subtype on the basis of a low or undetectable HIV-1 viral load, by the Amplicor HIV-1 Monitor test,
version 1
.0, in conjunction with either a declining CD4 cell count or history of travel outside the United States. Use of
version 1
.5 of the Amplicor HIV-1 Monitor test detected a median HIV-1 viral load that was 2.0 log(10) RNA copies/mL higher than was determined with
version 1
.0. Clinical management was altered in all cases after diagnosis of a non-B-subtype infection. These cases demonstrate that it is critical for physicians to suspect and diagnose non-B subtypes of HIV-1 so that an assay with reliable subtype performance can be used to guide antiretroviral therapy.
...
PMID:Clinical implications of identifying non-B subtypes of human immunodeficiency virus type 1 infection. 1101 32
This study determined the proficiencies of laboratories measuring human
immunodeficiency
virus type 1 (HIV-1) viral loads and the accuracies of two assays used for HIV-1 viral load measurement in Australia and investigated the variability of the new versions of these assays. Quality assessment program panels containing (i) dilutions of HIV-1 subtype B, (ii) replicates of identical samples of HIV-1 subtype B, and (iii) samples of subtype E and B were tested by laboratories. Total variability (within and between laboratories) was tested with quality control samples. The coefficients of variation (CVs) for the Roche AMPLICOR HIV-1 MONITOR version (v) 1.0 and Chiron Quantiplex bDNA 2.0 assays ranged from 53 to 87% and 22 to 31%, respectively. The widespread occurrence of invalid runs with the AMPLICOR HIV-1 MONITOR 1.0 assay was identified. The CVs of the new versions of the assays were 82 to 86% for the AMPLICOR HIV-1 MONITOR v 1.5 assay and 16 to 23% for the Quantiplex bDNA 3.0 assay. For virus dilution samples, all but 5 of 19 laboratories obtained results within 2 standard deviations of the mean. The Quantiplex bDNA 2.0 assay reported values lower than those reported by the AMPLICOR HIV-1 MONITOR
version 1
.0 assay for samples containing HIV-1 subtype B, whereas the reverse was true for subtype E. Identification and resolution of the problem of invalid runs markedly improved the quality of HIV-1 viral load testing. The variability observed between laboratories and between assays, even the most recent versions, dictates that monitoring of viral load in an individual should always be by the same laboratory and by the same assay. Results for an individual which differ by less than 0.5 log(10) HIV-1 RNA copy number/ml should not be considered clinically significant.
...
PMID:Quality of human immunodeficiency virus viral load testing in Australia. 1106 62
The performance and characteristics of Roche COBAS AMPLICOR HIV-1 MONITOR
version 1
.5 (CA MONITOR 1.5) UltraSensitive (usCA MONITOR 1. 5) and Standard (stCA MONITOR 1.5) procedures, Organon Teknika NucliSens HIV-1 RNA QT with Extractor (NucliSens), and Bayer Quantiplex HIV RNA version 3.0 (bDNA 3.0) were compared in a multicenter trial. Samples used in this study included 460 plasma specimens from human
immunodeficiency
virus (HIV) type 1 (HIV-1)-infected persons, 100 plasma specimens from HIV antibody (anti-HIV)-negative persons, and culture supernatants of HIV-1 subtype A to E isolates diluted in anti-HIV-negative plasma. Overall, bDNA 3.0 showed the least variation in RNA measures upon repeat testing. For the Roche assays, usCA MONITOR 1.5 displayed less variation in RNA measures than stCA MONITOR 1.5. NucliSens, at an input volume of 2 ml, showed the best sensitivity. Deming regression analysis indicated that the results of all three assays were significantly correlated (P < 0.0001). However, the mean difference in values between CA MONITOR 1.5 and bDNA 3.0 (0.274 log(10) RNA copies/ml; 95% confidence interval, 0.192 to 0.356) was significantly different from 0, indicating that CA MONITOR 1.5 values were regularly higher than bDNA 3.0 values. Upon testing of 100 anti-HIV-negative plasma specimens, usCA MONITOR 1.5 and NucliSens displayed 100% specificity, while bDNA 3.0 showed 98% specificity. NucliSens quantified 2 of 10 non-subtype B viral isolates at 1 log(10) lower than both CA MONITOR 1.5 and bDNA 3.0. For NucliSens, testing of specimens with greater than 1,000 RNA copies/ml at input volumes of 0.1, 0.2, and 2.0 ml did not affect the quality of results. Additional factors differing between assays included specimen throughput and volume requirements, limit of detection, ease of execution, instrument work space, and costs of disposal. These characteristics, along with assay performance, should be considered when one is selecting a viral load assay.
...
PMID:Multicenter comparison of Roche COBAS AMPLICOR MONITOR version 1.5, Organon Teknika NucliSens QT with Extractor, and Bayer Quantiplex version 3.0 for quantification of human immunodeficiency virus type 1 RNA in plasma. 1106 65
The performance of the LCx HIV RNA Quantitative (LCx HIV), AMPLICOR HIV-1 MONITOR
version 1
.5 (MONITOR v1.5), and Quantiplex HIV-1 RNA version 3.0 (bDNA v3.0) viral load assays was evaluated with 39 viral isolates (3 A, 7 B, 6 C, 4 D, 8 E, 4 F, 1 G, 4 mosaic, and 2 group O). Quantitation across the assay dynamic ranges was assessed using serial fivefold dilutions of the viruses. In addition, sequences of gag-encoded p24 (gag p24), pol-encoded integrase, and env-encoded gp41 were analyzed to assign group and subtype and to assess nucleotide mismatches at primer and probe binding sites. For group M isolates, quantification was highly correlated among all three assays. In contrast, only the LCx HIV assay reliably quantified group O isolates. The bDNA v3.0 assay detected but consistently underquantified group O viruses, whereas the MONITOR v1.5 test failed to detect group O viruses. Analysis of target regions revealed fewer primer or probe mismatches in the LCx HIV assay than in the MONITOR v1.5 test. Consistent with the high level of nucleotide conservation is the ability of the LCx HIV assay to quantify efficiently human
immunodeficiency
virus type 1 group M and the genetically diverse group O.
...
PMID:Comparative performance of three viral load assays on human immunodeficiency virus type 1 (HIV-1) isolates representing group M (subtypes A to G) and group O: LCx HIV RNA quantitative, AMPLICOR HIV-1 MONITOR version 1.5, and Quantiplex HIV-1 RNA version 3.0. 1123 Mar 96
Plasma specimens collected in 1999 from 32 human
immunodeficiency
virus type 1 (HIV-1)-infected foreigners living in Madrid, Spain, were examined for the presence of non-B subtypes. Furthermore, plasma viremia was quantified using two different AMPLICOR HIV-1 MONITOR tests,
version 1
.0 and the new upgraded and automated
version 1
.5 (COBAS). Most patients came from Africa, where they most likely had acquired HIV-1 infection through sexual contact. HIV-1 genetic subtyping was based on the phylogenetic analysis of the protease gene. Twenty-two subtype B, six subtype G, two subtype C, one subtype A, and one D subtype infection were found. Overall, non-B subtypes represented 31.25% of the study population. Irrespective of the HIV-1 variant, viral load values above the detection limit (200 HIV RNA copies/ml) increased from 56.2 to 71.9% for results obtained using MONITOR
version 1
.0 and COBAS, respectively. Moreover, significant differences in viral load values (>0.5 logs) were recognized in up to 37.5% of samples. In summary, COBAS seemed to be more reliable for testing plasma viral load in HIV-infected immigrants living in Spain, one third of whom carried non-B subtypes.
...
PMID:Prevalence of human immunodeficiency virus type 1 (HIV-1) non-B subtypes in foreigners living in Madrid, Spain, and comparison of the performances of the AMPLICOR HIV-1 MONITOR version 1.0 and the new automated version 1.5. 1132 2
1
2
3
4
Next >>