Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Pivot Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Target Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Query: UMLS:C0021051 (
immunodeficiency
)
71,517
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
Immunoassays for human
immunodeficiency
virus antigen (HIV Ag) and for antibody to HIV core and envelope (
CIA
-RA) were done on serial specimens from 40 haemophiliacs who had become seropositive on screening by enzyme-linked immunosorbent assay (ELISA). HIV Ag was detectable in 9 subjects and antibodies to envelope in 11 subjects before ELISA seroconversion. The apparent sequence of markers is HIV Ag, antibody to envelope, then antibody to core. Antigenaemia could be detected as soon as 2 weeks after infection and lasted 3-5 months. 82% agreement was seen between
CIA
-RA and western blot;
CIA
was more sensitive to envelope antibody and western blot was more sensitive to core antibody.
...
PMID:Serological markers in early stages of human immunodeficiency virus infection in haemophiliacs. 287 29
The second-generation enzyme immunoassays (EIAs) for antibodies against human
immunodeficiency
virus (HIV) from three manufacturers (Abbott, Organon, Wellcome) and three anti-HIV confirmatory tests, i.e. Western Blot (WB, Biotech, Dupont), radioimmunoprecipitation assay (RIPA, CLB) and a competitive immunoassay (
CIA
, Abbott) were evaluated on a panel of 6,488 serum samples, which had previously been used for the comparison of seven first-generation EIAs. For the present study the panel was expanded with sequential serum samples from 12 individuals followed at 1- to 3-month intervals during seroconversion for anti-HIV. The second-generation EIAs and confirmatory tests were significantly more sensitive than the first-generation EIAs as was demonstrated by detection of 10- to 100-fold higher endpoint titers in anti-HIV-positive sera as well as by earlier detection of anti-HIV in 7-11 of the 12 subjects, who seroconverted. In all sera obtained during early HIV infection anti-gp 160/120env antibodies (WB,
CIA
) were found in addition to anti-p24 (WB, RIPA) and in serial twofold dilutions of these 'seroconversion samples' the new Abbott EIA and RIPA were significantly more sensitive than WB (p less than 0.05), whereas
CIA
and the new Organon EIA were significantly less sensitive than WB (p less than 0.05). The new Wellcome EIA was not statistically less sensitive than WB. The
CIA
was as sensitive as WB for antibodies to envelope proteins (gp41, gp160, gp120), but considerably less sensitive for core (p24) antibodies, as was shown in sera obtained during early as well as later clinical stages of HIV infection.(ABSTRACT TRUNCATED AT 250 WORDS)
...
PMID:Evaluation of three second-generation and three confirmatory assays for antibodies to human immunodeficiency virus. 328 66