Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: UMLS:C0020473 (hyperlipidemia)
15,891 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

Oxyhemoglobin dissociation curves (ODC) were performed on blood from diabetic and nondiabetic subjects with and without hypertriglyceridemia. P50 at in vivo pH was slightly lower than normal in normolipemic diabetics (25.7 versus 26.6 mmHg, p less than 0.05), in spite of increased red cell 2,3-diphosphoglycerate concentration (15.4 versus 14.4 mumole/g Hg, p less than 0.025). P50 at in vivo pH in diabetics with moderately elevated very low density lipoproteins (VLDL)--Type IV hyperlipoproteinemia (HLP)--was likewise found to be slightly lower than normal (25.5 versus 26.6 mmHg, p less than 0.05). In contrast, diabetics with pronounced hyperlipemia due to accumulation of chylomicrons (type I HLP) or due to accumulation of chylomicrons (type I HLP) or due to accumulation of chylomicrons as well as VLDL (type V HLP) showed markedly increased hemoglobin--oxygen affinity (P50:21.1 versus 26.6 mmHg, p less than 0.001). The change in the ODC of normolipemic diabetics is considered to be an expresssion of the presence of an increased proportion of a hemoglobin fraction (Hb Alc) with increased oxygen affinity. The additional change in the ODC of the hyperlipemic patients is thought to be secondary to accumulation of triglyceride-rich particles for the following reasons: (1) a similar increase in oxygen affinity of hemoglobin was demonstrated in familial type I HLP of nondiabetic subjects; (2) normal red cells increased their oxygen affinity when incubated in lactescent plasma; (3) in both acquired types I and V HLP the disappearance of HLP was followed by a normalization of the ODC.
...
PMID:Hyperlipoproteinemia, diabetes, and oxygen affinity of hemoglobin. 1 60

Oxyhemoglobin dissociation curves were performed from blood of subjects with pancreatitis associated with Type V and Type I hyperlipoproteinemia. The hemoglobin-oxygen affininty was markedly increased with P50 varying from 22.3 to 17.7 mmHg. As the hyperlipoproteinemia subsided the clinical and laboratory signs of pancreatic affection disappeared. The increased hemoglobin-oxygen affinity and decreased flow of red cells due to hyperchylomicronemia in the microcirculation may lead to tissue hypoxia, which may act as a precipitating injurious factor leading to pancreatitis during severe hyperlipemia.
...
PMID:Increased hemoglobin-oxygen affinity in patients with pancreatitis associated with type I and V hyperlipoproteinemia. 2 74

We describe the application of the microencapsulated-antibody technique to the radioimmunoassay of digoxin in serum. Droplets of emulsified rabbit antibody are microencapsulated in a semipermeable nylon membrane by an interfacial polymerization technique. The antibody microcapsules are incubated with 125I-labeled digoxin and unlabeled digoxin for 15 min at 37 degrees C, then free and bound digoxin are separated by centrifugation. Subtherapeutic, therapeutic, and toxic concentrations of digoxin in sera can be determined, with use of a standard curve prepared by use of known amounts of digoxin. With this technique we obtained an intra-laboratory correlation coefficient of 0.945 for 100 patients' sera and one of 0.940 for interlaboratory results for 21 sera (10 laboratories) when compared to a routine clinical laboratory radioimmunoassay for digoxin. Icterus, lipemia, hemoglobin, or disproteinemia had no effect on the analytical recovery of digoxin. The standard curve was linear to 6 microgram/L; the sensitivity was 0.25 microgram/L.
...
PMID:Microencapsulated antibodies in radioimmunoassay--I. Determination of digoxin. 8 88

Three levels of iron (5, 29, 307 ppm iron) were fed to rats from conception through the 18th day of lactation. Dams in the 5 ppm iron group and pups in the 5 and 29 ppm iron groups developed anemia characterized by lower hemoglobin and hematocrit values than control animals. Liver and spleen levels of iron in dams and pups in the 5 and 29 ppm iron groups were lower than in the 307 ppm iron groups. Milk iron was lower in the 5 ppm iron group than in the 29 and 307 ppm iron groups. Pups in the 5 ppm iron group had hyperlipidemia characterized by elevated serum triglycerides, cholesterol, and phospholipids. Milk lipids and post-heparin plasma lipoprotein lipase levels in pups did not differ among experimental groups. Triglyceride and CO2 production from [U-14C]glucose were significantly greater in the iron-deficient pups than in control pups. Hyperlipidemia in 18-day-old iron-deficient rat pups appears to be related to increased endogenous production of triglycerides.
...
PMID:Iron deficiency hyperlipidemia in 18-day-old rat pups: effects of milk lipids, lipoprotein lipase, and triglyceride synthesis. 61 36

This report describes a new specific colorimetric procedure for uric acid assay with AutoAnalyzer II and SMA (Technicon) systems, made specific by the application of uricase. Hydrogen preroxide, formed in this reaction, effects the oxidative coupling of 4-aminophenazone and 2,4-dichlorophenol under the catalytic influence of peroxidase. The red dye formed is measured at 505 or 520 nm. A sample blank measurement is not necessary, and the reagents show very good stability. The test shows linearity up to 714 mumol of uric acid per liter. Results of thie method correlate very well with those by the uricase-ultraviolet and uricase--catalase methods. There is no interference by hemoglobin, bilirubin, lipemia, and various drugs, except a minor interference by alpha-methyldopa. Interference from ascorbate is eliminated by ascorbate oxidase. This method can be regarded as a considerably improved routine test for uric acid on continuous-flow systems in clinical laboratories as compared with the commonly used phosphotungstate method.
...
PMID:Determination of uric acid on continuous-flow (AutoAnalyzer II and SMA) systems with a uricase/phenol/4-aminophenazone color test. 62 57

We assessed the analytical performance of the co-immobilized hexokinase (EC 2.7.1.1) and glucose-6-phosphate dehydrogenase (EC 1.1.1.49) method for D-glucose analysis on the Technicon SMAC. The enzyme-containing coils were usable for one month, or 12 000 tests. Bilirubin, hemoglobin, lipemia, creatinine, uric acid, citric acid, and ascorbic acid did not interfere. Results with this method were compared to those by the National Glucose Reference Method. The upper limits of the total error estimate (a combination of random and systematic errors) were 76, 74, and 125 mg/liter at concentrations of 500, 1200, and 3000 mg/liter, respectively. The error estimates were less than allowable errors based on medical usefulness; thus the method was judged to perform acceptably with respect to the Reference Method. We also present performance data for the routine SMAC glucose oxidase (EC 1.1.3.4)/Peroxidase (EC 1.11.1.7) 3-methyl-2-benzothianolinone hydrazone-N,N-dimethylaniline method, the direct hexokinase method with the Du Pont aca, and the glucose oxidase oxygen-rate method with the Beckman Glucose Analyzer.
...
PMID:Evaluation of the co-immobilized hexokinase/glucose-6-phosphate dehydrogenase method for glucose, as adapted to the Technicon SMAC. 65 1

Studies are reported on the reaction kinetics of the glucose assay according to Trinder which involves the specific oxidation of glucose by glucose oxidase and the determination of the hydrogen peroxide released by means of phenol and 4-aminophenazone in the presence of peroxidase. The results have been used to develop a general kinetic fixed-time method for the analysis of glucose in whole blood and serum. The single reagent method has been adapted to the ENI GEMSAEC centrifugal analyzer and to the Abbott ABA-100 analyzer. The procedures exhibited excellent precision and the results correlated well with those obtained by the hexokinase method, Linearity was achieved from 3 to 64 mmol/1 glucose for the GEMSAEC method, and from 3 to 33 mmol/1 glucose for the ABA-100 method. Reagent or sample blank corrections were not necessary. There were no interferences from various drugs, hemoglobin, bilirubin, or lipemia.
...
PMID:Kinetic enzymatic method for automated determination of glucose in blood and serum. 83 60

We describe the effects of uric acid, hemolysis, drugs, ascorbic acid, lipemia, and bilirubin on the enzymic measurement of cholesterol in serum by use of reagent kits from Abbott, Beckman, Boehringer Mannheim, Calbiochem, and Worthington. In all of these, the chromogen formed from the reaction of hydrogen peroxide with phenol and 4-aminoantipyrene is measured. The absorbance was measured at 500 nm vs. a serum blank for each kit--except Abbott's with which the recorded absorbances were the differences between readings at 500 and 600 nm. With all reagents kits, there was no interference from uric acid up to 200 mg/liter, hemoglobin up to 1.0 g/liter, or drugs (clofibrate, phenobarbital, Ketochol, Ovral-28), but negative interferences from ascorbic acid. Except for the Abbott kit, the cholesterol values obtained for lipemic samples were lower than found with the comparison method [Abell et al., Stand. Methods Clin. Chem. 2, 26 (1958)]. With Abbott's reagents, for most lipemic samples, the values were the same. Bilirubin at concentrations of 200 mg/liter significantly decreased the cholesterol values with Beckman, Calbiochem, and Worthington reagent kits. With Boehringer Mannheim reagent a small negative interference was observed and with Abbott reagent a small positive interference was observed when the bilirubin concentrations were 200 mg/liter.
...
PMID:Interference with the enzymic measurement of cholesterol in serum by use of five reagent kits. 84 75

The Corning 940 Titrator, which measures total calcium concentration by titration with [ethylenebis(oxyethylenenitrilo)]tetraacetic acid, was evaluated for use in hospital laboratory. Calcium values for patients' sera were about 0.3 mg/dl lower as measured with the Titrator than with the Technicon SMA 12/60 continuous-flow analyzer. A similar bias was evident when the results with the Titrator were compared with those from atomic absorption spectrophotometry. Agreement was better in the low range and worse in the high range. Within-day and between-day coefficients of variation on the Titrator were about 1.5% and 2.5%, respectively. We saw no interference from magnesium, phosphorus, bilirubin, or in the presence of lipemia. At extremely increased hemoglobin concentrations (500 mg/dl), there is a 5% inhibition. Titrator results for patients' urine samples correlated closely (n = 0.999) with those obtained with the SMA 12/60.
...
PMID:Evaluation of the Corning 940 Calcium Titator for use with serum and urine. 111 34

In veterinary medicine, PCV determined by centrifugation of blood in a microhematocrit tube is the most common clinical test used to initially assess and monitor anemic and polycythemic animals. In contrast, blood hemoglobin (Hb) concentration, rather than PCV, is generally determined in human patients. One automated system photometrically measures blood Hb concentration after conversion of Hb to azide methemoglobin without dilution and was found to be a simple and accurate instrument for use in human medicine. We evaluated the system for its accuracy in measuring blood Hb concentration in animals by comparing it with standard techniques and for its suitability in veterinary practice. Blood samples, anticoagulated with potassium EDTA, from 78 healthy animals (33 dogs, 17 cats, 13 horses, and 15 cows) and 58 dogs and 4 cats with various blood abnormalities (10 anemia, 11 polycythemia, 21 lipemia, 16 leukocytosis, and 6 icterus) were analyzed. In all species, blood Hb concentration of healthy animals determined by the system was comparable to that measured by standard cyanmethemoglobin methods (ie, an automated counter; rI = 0.987 to 0.998 and a hemoglobin kit, rI = 0.946 to 0.993). The aforementioned system also yielded similar values to those obtained by use of standard methods in anemic, polycythemic, and icteric dogs and cats. Moreover, the system reads the absorbance at 2 wavelengths to correct for turbidity, and therefore, accurately measured Hb concentration in blood samples with severe lipemia (triglycerides concentration > 500 mg/dl) and marked leukocytosis (> 50,000 WBC/microliter), whereas other standard Hb techniques are known to give falsely high results.(ABSTRACT TRUNCATED AT 250 WORDS)
...
PMID:Evaluation of an automated system for hemoglobin measurement in animals. 145 15


1 2 3 4 5 6 7 8 9 10 Next >>