Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: UMLS:C0020473 (hyperlipidemia)
15,891 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

This paper describes the evaluation of a heterologous enzyme immunoassay for the determination of total thyroxine in serum by a group of seven clinical chemical laboratories. The test follows the principles of the enzyme linked immunosorbent assay (ELISA) and uses peroxidase as a marker. The evaluation of analytical reliability yielded the following results within the analytical range from 39 unto 322 nmol/l: 1. Within-batch precision ranged from 3.1 unto 10.4% (coefficient of variation) with single analyses. 2. Between-batch precision ranged from 3.7 unto 20.4% with single analyses. 3. Between-laboratories precision ranged from 5.4 unto 6.8%. 4. Pure thyroxine, added to serum or thyroxine-free serum, gave recoveries between 93 and 120%. 5. Analysis of control sera gave results essentially comparable to the assigned values based upon radioimmunoassays. 6. Analysis of 288 clinical sera gave slightly higher results by the enzyme immunoassay than by the analogous radioimmunoassay from the same manufacturer. 7. Comparison with other methods of analysis (radioimmunoassays, competitive protein ligand assays, hormonal iodine assay) yielded partly comparable, partly higher results. 8. Comparison with the homogenous enzyme immunoassay (EMIT) led to comparable results. 9. Interference due to hyperlipemia or hemolysis was not observed. 10. There might be an interference in hyperbilirubinaemic sera, due to an as yet unknown factor. With respect to practicability the ELISA-test compares favourably with the analogous solid phase radioimmunoassay. The main differences are the absence of radioactive material and a longer shelf-live of reagents. Following the manual procedure the time taken to perform the enzyme immunoassay is slightly longer than for the analogous radioimmunoassay.
...
PMID:[Determination of thyroxine in serum by a heterogeneous enzyme immunoassay: results of a joint trial]. 38 82

This report describes a new specific colorimetric procedure for uric acid assay with AutoAnalyzer II and SMA (Technicon) systems, made specific by the application of uricase. Hydrogen preroxide, formed in this reaction, effects the oxidative coupling of 4-aminophenazone and 2,4-dichlorophenol under the catalytic influence of peroxidase. The red dye formed is measured at 505 or 520 nm. A sample blank measurement is not necessary, and the reagents show very good stability. The test shows linearity up to 714 mumol of uric acid per liter. Results of thie method correlate very well with those by the uricase-ultraviolet and uricase--catalase methods. There is no interference by hemoglobin, bilirubin, lipemia, and various drugs, except a minor interference by alpha-methyldopa. Interference from ascorbate is eliminated by ascorbate oxidase. This method can be regarded as a considerably improved routine test for uric acid on continuous-flow systems in clinical laboratories as compared with the commonly used phosphotungstate method.
...
PMID:Determination of uric acid on continuous-flow (AutoAnalyzer II and SMA) systems with a uricase/phenol/4-aminophenazone color test. 62 57

Studies are reported on the reaction kinetics of the glucose assay according to Trinder which involves the specific oxidation of glucose by glucose oxidase and the determination of the hydrogen peroxide released by means of phenol and 4-aminophenazone in the presence of peroxidase. The results have been used to develop a general kinetic fixed-time method for the analysis of glucose in whole blood and serum. The single reagent method has been adapted to the ENI GEMSAEC centrifugal analyzer and to the Abbott ABA-100 analyzer. The procedures exhibited excellent precision and the results correlated well with those obtained by the hexokinase method, Linearity was achieved from 3 to 64 mmol/1 glucose for the GEMSAEC method, and from 3 to 33 mmol/1 glucose for the ABA-100 method. Reagent or sample blank corrections were not necessary. There were no interferences from various drugs, hemoglobin, bilirubin, or lipemia.
...
PMID:Kinetic enzymatic method for automated determination of glucose in blood and serum. 83 60

A monoclonal antibody-based direct binding enzyme-linked immunosorbent assay (ELISA) for apoprotein (apo) B-100 has been developed for use as a reference method. The assay uses the two well-characterized monoclonal antibodies, MB24 and MB47. MB47, which recognizes an epitope at the low density lipoprotein (LDL) receptor-binding domain of apoB and is specific for apoB-100, is bound to the microtiter plate as the capture antibody. MB24, which binds an epitope in the amino terminal half of the apoB-100 and identifies both apoB-100 and apoB-48, is conjugated to horseradish peroxidase and is utilized as the indicating antibody. The assay was calibrated with LDL (d 1.030-1.050 g/ml) and the LDL protein was determined by a sodium dodecyl sulfate (SDS) Lowry procedure. The working range of the assay is 0.25-1.25 micrograms/ml. Optimal dilution of whole plasma was found to be 1:2000. In the assay, MB47 bound approximately 97% of the apoB in all low density lipoprotein, and greater than 90% of the apoB in the majority of very low density lipoprotein preparations. Small dense LDL from subjects with familial combined hyperlipidemia (FCHL) and large bouyant LDL from subjects with familial hypercholesterolemia (FH) exhibited binding properties similar to LDL from healthy normolipidemic subjects when tested in the reference ELISA. The intra- and interassay coefficients of variation averaged 2.5% and 6.0%, respectively. Plasma B-100 levels were not influenced by freezing and thawing or storage at 4 degrees C for up to 3 weeks or storage at -70 degrees C for up to 11 months. Excellent agreement was obtained between the reference ELISA and a polyclonal RIA which measures total apoB (r = 0.93, n = 105, mean ELISA B-100 value = 100 mg/dl, mean RIA value = 101 mg/dl, Sy = 9.6). Reference ELISA B-100 values of samples pretreated with bacterial lipase were not significantly increased in most samples with plasma triglyceride levels below 600 mg/dl. To help reduce the large among-laboratories variability of apoB measurements, we recommend that this candidate reference direct binding ELISA be used to assign apoB target values to apoB reference pools.
...
PMID:Evaluation of a monoclonal antibody-based enzyme-linked immunosorbent assay as a candidate reference method for the measurement of apolipoprotein B-100. 260 May 45

Polymorphism at the apolipoprotein E (ApoE) locus is an important factor in the development of remnant (Type III) hyperlipidemia and also influences the distribution of cholesterol concentrations in the population. The new method for ApoE phenotyping described here gives good results with simple apparatus. Serum (10 microL) is digested with sialidase (EC 3.2.1.18), delipidated, and redissolved in 6 mol/L urea. Electrofocusing is carried out in agarose, followed by immunoblotting with a monoclonal antibody to ApoE and an anti-immunoglobulin-peroxidase conjugate. Sialidase-catalyzed digestion effectively removes sialated forms of ApoE, which eases interpretation. This method can be used in nonspecialist laboratories and is particularly suited for assay of large numbers of samples.
...
PMID:Apolipoprotein E phenotype determined by agarose gel electrofocusing and immunoblotting. 279 Dec 74

In autoimmune hyper- or dislipidemia secondary to a monoclonal antilipoprotein gammapathy, immunoglobulin-lipoprotein (Ig-Lp) complexes are found in the circulating blood. In order to determine their possible significance in common types of hyperlipidemia we compared the Ig-Lp content of sera from 98 healthy blood donors and 155 outpatients from a Lipid Clinic, including 91 cases of hypercholesterolemia (55 familial and 36 non-familial), 15 cases of hypertriglyceridemia, 20 cases of mixed hyperlipidemia and 29 miscellaneous cases. Detection of the Ig-Lp was performed by an ELISA technique with polyclonal affinity purified anti-LDL + HDL as capture antibodies and peroxidase-labeled anti-Ig antibodies specific for IgA, IgG, IgM heavy chains as indicators. Two cases of monoclonal gammapathy (one IgA K and one IgG L) with dislipidemia served as positive controls for the test. IgG, IgA and IgM Lp were found in the sera of the blood donors, in very small quantities when compared with the monoclonal gammapathy cases. All three types of Ig-Lp were also found in the different hyperlipidemic populations studied. When blood donors were compared to hyperlipidemic patients, no difference was observed for IgG Lp. A significant increase in IgM Lp was found in patients with familial hypercholesterolemia (P less than 0.01). An increase in IgA Lp was also found in hypercholesterolemia, familial or not (P less than 0.01), and in patients with corneal arcus (P less than 0.0001), ischaemic disease (P less than 0.01), tendon xanthomas (P less than 0.05) or xanthelasma (P less than 0.05). Furthermore, in a group of 18 paired parents from 9 different families, positive interparent correlations were found for IgM Lp (r = 0.78; P = 0.013) and IgG Lp (r = 0.69; P = 0.038). Therefore IgM Lp may be markers for subpopulations of familial hypercholesterolemia, and IgA Lp markers for the risk of atherosclerotic ischemic disease and deposition of lipids in the cornea. It may be (1) that natural clones of autoanti-lipoprotein antibodies are responsible for the minute quantities of Ig-Lp found in normal people; (2) that the marked development of one of these clones is the cause of autoimmune hyper- or dyslipidemia and xanthomatosis associated with monoclonal gammapathy; (3) that the limited development of a clone produces the Ig-Lp particles found in hypercholesterolemic patients; (4) that there are types of Ig-Lp particles (IgA Lp) that may be harmful for tissues independently of hypercholesterolemia.
...
PMID:Immunoglobulin-bound lipoproteins (Ig-Lp) as markers of familial hypercholesterolemia, xanthomatosis and atherosclerosis. 324 Mar 31

Permeability of intracranial extracerebral arteries of stroke-prone spontaneously hypertensive rats (SHRSP) was studied using labeling techniques (ferritin and horseradish peroxidase), at the cellular level. In the arterial endothelial cells, the tracer molecules were slowly but constantly transported by the plasmalemmal vesicles to the subendothelial space. This endothelial transportation of the tracers into these cerebral arteries did not seem to be significantly influenced by aging, increased blood pressure, hyperlipidemia or the existence of cerebral bleeding and infarction. Around the adventitia, there were a great number of periadventitial capillaries, especially near bifurcations. In the periadventitial capillaries, the tracer molecules were readily trapped by endothelial cells and were quickly transported to pericapillary spaces. The tracer molecules were then detected in the phagocytes adjacent to the deeper layers of the media, and further in the medial smooth muscle cells. The possibility that large amounts of plasma components are supplied to the media from periadventitial capillaries in the intracranial extracerebral arteries has to be considered in the pathogenic mechanisms of cerebrovascular lesions.
...
PMID:Permeability of intracranial extracerebral vessels in stroke-prone SHR. 730 76

The development of experimental atherosclerosis was studied in subtotally nephrectomized rats which were subjected to preimmunization with horseradish peroxidase and subsequent feeding with atherogenic diet. Both in sham-operated pair-fed control animals and in uremic animals, the atherogenic diet caused hyperlipemia which was more pronounced in uremic than in control animals (control animals: triglycerides 1.11 +/- 0.04 mmol/l; cholesterol 5.82 +/- 0.21 mmol/l; uremia: triglycerides 1.33 +/- 0.06; cholesterol 10.9 +/- 0.31). An increase of cholesterol was seen both in the VLDL and in the LDL fractions. Despite more pronounced hyperlipemia, lipid concentration in the aortic wall was not increased nor were more marked histological abnormalities encountered in the aorta of uremic animals (cholesterol-fed control: cholesterol 95.4 +/- 4.4 micrograms/mg protein; phospholipids 2.42 +/- 0.9 micrograms/ml protein; cholesterol-fed uremia: cholesterol 96.8 +/- 4.9; phospholipids 2.52 +/- 0.8). The results suggest that despite hyperlipemia short-term experimental renal insufficiency does not promote atherogenesis.
...
PMID:Atherogenesis in experimental uremia. 733 7

Prothrombin fragment 1.2 (F1.2) is an activation peptide generated during a critical event of blood coagulation, the conversion of prothrombin to thrombin. As a marker of thrombin generation, F1.2 has clinical potential in assessing thrombotic risk and monitoring anticoagulant therapy. In developing a highly specific, monoclonal antibody-based immunoassay of human plasma F1.2, we generated six murine anti-F1.2 monoclonal antibodies, using as immunogen a synthetic peptide (sequence: CGSD-RAIEGR) similar to the unique carboxyl terminus of F1.2. Each antibody bound F1.2 but not prothrombin. Epitope mapping studies with one antibody (5-3B) showed that optimum binding required six to eight amino acids plus a terminal arginine to emulate the F1.2 carboxyl terminus. A quantitative sandwich ELISA for human plasma F1.2 was configured with monoclonal antibody 5-3B as the capture antibody and peroxidase-labeled polyclonal antibodies to the F1.2 amino-terminal region as detector antibodies. Calibrators were prepared by adding purified F1.2, 0-10 nmol/L, to F1.2-depleted plasma. Assay characteristics included the following: mean (+/- SD) analytical recovery of 98% +/- 13%; no interference from lipemia, hemolysis, icterus, or thrombolytic agents; 0.08 nmol/L sensitivity; and mean intra- and interassay imprecision (three lots) < 12% at both low and high concentrations of F1.2.
...
PMID:Monoclonal antibodies specific for prothrombin fragment 1.2 and their use in a quantitative enzyme-linked immunosorbent assay. 847 48

A 35-years old female with Jordans' anomaly was reported. She had been treated for diabetes mellitus and hypertension at another hospital. She was admitted to our hospital for operation for diabetic retinopathy on July 9, 1992. Wright-Giemsa stained peripheral blood smear revealed multiple vacuoles in the cytoplasm of the granulocytes and monocytes. Histochemical studies of these vacuoles showed positive for Sudan III but negative for peroxidase, alkaline phosphatase and PAS staining. Electron microscopic examination revealed that lipid containing vacuoles had no clear membrane and were not associated with cell organelles. Laboratory findings of the serum showed hyperglycemia (FBS 188mg/dl), high HbA1c level (9.4%) and mild type IIa hyperlipidemia. Abdominal sonogram and abdominal CT showed no remarkable abnormalities except for mild fatty liver. Her elder sister and daughter had similar morphological findings in granulocytes, monocytes and lymphocytes.
...
PMID:[A case of Jordans' anomaly]. 786 17


1 2 3 Next >>