Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: UMLS:C0019693 (HIV)
170,526 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

Efavirenz and nevirapine are non-nucleoside reverse transcriptase inhibitors for the treatment of HIV-1-infected individuals. A simple and rapid high-performance liquid chromatographic method for the simultaneous quantification of efavirenz and nevirapine in human plasma suitable for therapeutic drug monitoring is described. Sample pre-treatment consisted of protein precipitation with acetonitrile and subsequently dilution with distilled water. The drugs were separated from endogenous compounds by isocratic reversed-phase high-performance liquid chromatography with ultraviolet detection at 275 nm. The method was validated over the therapeutically relevant concentration range of 0.05-15.0 mg l(-1) and 0.25-15.0 mg l(-1) for efavirenz and nevirapine, respectively, using a volume of 100 microl of plasma. The calibration curves were linear over this concentration range. Carbamazepine was used as internal standard. The assay proved to be accurate (accuracies varied between -12.7 and 8.5%) and precise (intra- and inter-assay precisions were less then 5.9%). The tested batches of control human plasma and frequently co-administered drugs did not interfere with the described methodology. Efavirenz and nevirapine were stable under various relevant storage conditions. This validated assay is suited for use in pharmacokinetic studies with efavirenz and nevirapine and can readily be implemented in the setting of a hospital laboratory for the monitoring of efavirenz and nevirapine concentrations.
...
PMID:Simple and rapid method for the simultaneous determination of the non-nucleoside reverse transcriptase inhibitors efavirenz and nevirapine in human plasma using liquid chromatography. 1286 43

A new high-performance liquid chromatography assay was developed for the determination of tenofovir, a nucleotide analogue, in plasma. A solid-liquid extraction procedure was coupled with a reversed-phase HPLC system. The system requires a mobile phase containing Na(2)HPO(4) buffer, tetrabutylammonium hydrogen sulfate and acetonitrile for different elution through a C(18) column with UV detection. The method proved to be accurate, precise and linear between 10 and 4000 ng/ml. The method was applied to determine trough levels of tenofovir in 11 HIV-infected patients with virologic failure under multiple antiretroviral therapy. This method was also successfully applied to a pharmacokinetic study in an HIV infected patient with renal failure.
...
PMID:Sensitive determination of tenofovir in human plasma samples using reversed-phase liquid chromatography. 1290 6

To evaluate uridine levels in humans we developed a very sensitive and specific high-performance liquid chromatographic method for the determination of uridine in serum. We use techniques which are available in a standard analytical laboratory. Chromatographic analysis was carried out on a Phenomenex Aqua C18 5 micro 125A column protected by a guard cartridge system. Potassium dihydrogen phosphate buffer-acetonitrile was used as an eluent and oxypurinol as the internal standard. All sample preparation steps were done at 4 degrees C and the autosampler was cooled down to 4 degrees C. The calibration curve was linear throughout the calibration range from 0.25 to 100 micromol/l. This method was primarily established to evaluate uridine serum levels in patients with HIV infection since patients on highly active antiretroviral therapy (HAART) might develop metabolic disturbances that could lead to severe and fatal lactic acidosis due to mitochondrial toxicity. It is suggested that a limited or inadequate uridine supply is at least in part responsible for the onset of such deterioration.
...
PMID:Liquid chromatographic method for the determination of uridine in human serum. 1506 46

An accurate, sensitive, and specific reverse-phase high-performance liquid chromatography (HPLC) assay for the simultaneous quantitative determination of HIV-protease inhibitors (PIs) (indinavir, IDV; amprenavir, APV; saquinavir, SQV; nelfinavir, NFV; ritonavir, RTV; and lopinavir, LPV) and non-nucleoside reverse transcriptase inhibitors (NNRTIs) (nevirapine, NVP; delavirdine, DLV; and efavirenz, EFV) in human blood plasma is described. The method provides excellent resolution and peak shape for nine analytes through a linear gradient (36-86%) of 25% phosphate buffer (pH 4.5), 60% acetonitrile, 15% methanol, and 0.75 ml TFA, with a gradient mobile phase flow rate (0.9-1.1 ml) over 30 min run time. The optimized solid phase extraction (SPE) extraction method using (1.0 ml, 100mg BOND ELUT-C18 Varian) column provides a clean base line and high extraction efficiency using a 550 microl plasma sample. The method was validated over the range of 10-10,000 ng/ml for NVP, IDV, and SQV; 10-5000 ng/ml for EFV; 25-10000 ng/ml for APV; and 25-5000 ng/ml for DLV, NFV, RTV, and LPV. This method is accurate (average accuracies of three different concentrations ranged from 91 to 112%), and precise (within- and between-day precision measures ranged from 0.2 to 5.7% and 0.1 to 5.4%, respectively). This method is suitable for use in clinical pharmacokinetic studies as well as in therapeutic drug monitoring (TDM).
...
PMID:High-performance liquid chromatography assay for the quantification of HIV protease inhibitors and non-nucleoside reverse transcriptase inhibitors in human plasma. 1513 96

A simple, rapid, sensitive and specific reversed-phase high performance liquid chromatographic (RP-HPLC) method involving ultraviolet detection (lambda = 210 nm) was developed for analysis of indinavir along with propranolol in samples obtained from ex vivo intestinal permeability studies. Chromatography was carried out on C-18 column with mobile phase comprising of phosphate buffer-acetonitrile (68:32, v/v) pumped at flow rate of 1 ml/min. The proposed method has a short run time of 12 min and involves a simple sample preparation for the purpose of reducing permeability model artifacts and to concentrate the samples. Fluorescein was used as internal standard. The proposed method has been validated with regard to specificity, detection limit, recovery, accuracy and precision. For both the drugs, method was found to be selective, linear (R(2) approximately 0.999), accurate (recovery = 100-105%) and precise (<3% R.S.D.) in the range of 2-20 microg/ml. The limit-of-detection and limit-of-quantification of the method were 40 ng/ml and 100 ng/ml for indinavir, and 30 and 80 ng/ml for propranolol, respectively. Indinavir, a widely prescribed HIV protease inhibitor, suffer from bioavailability problems where involvement of P-glycoprotein mediated drug efflux may play a significant role. The proposed method was successfully applied for intestinal permeability of indinavir to estimate the contribution of P-glycoprotein in limiting its oral bioavailability. The advantage of the developed method lies in the simultaneous determination of propranolol, a passive integrity marker, routinely employed in permeability studies and its selectivity in presence of various P-gp modulators and permeability markers.
...
PMID:Reversed-phase liquid chromatography with ultraviolet detection for simultaneous quantitation of indinavir and propranolol from ex-vivo rat intestinal permeability studies. 1517 39

A rapid and simple high-performance liquid chromatography method has been developed for the determination of the HIV-1 reverse transcriptase inhibitor abacavir in human plasma. It included a single liquid-liquid extraction procedure with a mixture of ethyl acetate-diethyl ether prior to reversed-phase chromatography on a C18 column and C18 precolumn insert. Ultraviolet detection was set at 285 nm. The mobile phase consisted of water-acetonitrile (83:17, v/v) and the flow rate was kept at 1 mL/min. The total run time for a single analysis was 10 min. The method has been validated over the range 50-2500 ng/mL. The assay was linear over the entire concentration range (r2 = 0.9993). Intra- and inter-day precision and accuracy were less than 8.1 and -5.2%, respectively. The extraction recovery was greater than 94.3%. Abacavir was stable under the relevant storage conditions tested. After the validation, the analytical error function was established as standard deviation (SD; ng/mL) = -1.072 + 0.037C (C = theoretical concentration value). The method developed and its associated analytical error function will be suitable for pharmacokinetic studies and monitoring of HIV-1 patients.
...
PMID:Determination of abacavir in human plasma by high-performance liquid chromatography with ultraviolet detection and the analytical error function. 1538 66

Chromatographic separation of highly polar basic drugs with ideal ionspray mass spectrometry volatile mobile phases is a difficult challenge. A new quantification procedure was developed using hydrophilic interaction chromatography-mass spectrometry with turbo-ionspray ionization in the positive mode. After addition of deuterated internal standards and simple clean-up liquid extraction, the dried extracts were reconstituted in 500 microL pure acetonitrile and 5 microL was directly injected onto a Waters Atlantis HILIC 150- x 2.1-mm, 3-microm column. Chromatographic separations of cocaine, seven metabolites, and anhydroecgonine were obtained by linear gradient-elution with decreasing high concentrations of acetonitrile (80-56% in 18 min). This high proportion of organic solvent makes it easier to be coupled with MS. The eluent was buffered with 2 mM ammonium acetate at pH 4.5. Except for m-hydroxy-benzoylecgonine, the within-day and between-day precisions at 20, 100, and 500 ng/mL were below 7 and 19.1%, respectively. Accuracy was also below +/- 13.5% at all tested concentrations. The limit of quantification was 5 ng/mL (%Diff < 16.1, %RSD < 4.3) and the limit of detection below 0.5 ng/mL. This method was successfully applied to a fatal overdose. In Switzerland, cocaine abuse has dramatically increased in the last few years. A 45-year-old man, a known HIV-positive drug user, was found dead at home. According to relatives, cocaine was self-injected about 10 times during the evening before death. A low amount of cocaine (0.45 mg) was detected in the bloody fluid taken from a syringe discovered near the corpse. Besides injection marks, no significant lesions were detected during the forensic autopsy. Toxicological investigations showed high cocaine concentrations in all body fluids and tissues. The peripheral blood concentrations of cocaine, benzoylecgonine, and methylecgonine were 5.0, 10.4, and 4.1 mg/L, respectively. The brain concentrations of cocaine, benzoylecgonine, and methylecgonine were 21.2, 3.8, and 3.3 mg/kg, respectively. The highest concentrations of norcocaine (about 1 mg/L) were measured in bile and urine. Very high levels of cocaine were determined in hair (160 ng/mg), indicating chronic cocaine use. A low concentration of anhydroecgonine methylester was also found in urine (0.65 mg/L) suggesting recent cocaine inhalation. Therapeutic blood concentrations of fluoxetine (0.15 mg/L) and buprenorphine (0.1 microg/L) were also discovered. A relatively high concentration of Delta(9)-THC was measured both in peripheral blood (8.2 microg/L) and brain cortex (13.5 microg/kg), suggesting that the victim was under the influence of cannabis at the time of death. In addition, fluoxetine might have enhanced the toxic effects of cocaine because of its weak pro-arrhythmogenic properties. Likewise, combination of cannabinoids and cocaine might have increase detrimental cardiovascular effects. Altogether, these results indicate a lethal cocaine overdose with a minor contribution of fluoxetine and cannabinoids.
...
PMID:A fatal overdose of cocaine associated with coingestion of marijuana, buprenorphine, and fluoxetine. Body fluid and tissue distribution of cocaine and its metabolites determined by hydrophilic interaction chromatography-mass spectrometry(HILIC-MS). 1551 97

HIV-1 Vpr is a highly conserved accessory protein that is involved in many functions of the virus life cycle. Vpr facilitates the entry of the HIV pre-integration complex through the nuclear pore, induces G2 cell cycle arrest, regulates cell apoptosis, increases transcription from the long terminal repeat and enhances viral replication. Vpr contains a Leu/Ile-rich domain (amino acids 60-81) in its C-terminal part, which is critical for dimerization. The sequence comprising residues 52-96 is implicated in properties of the protein such as DNA interaction and apoptosis via interaction with the adenine nucleotide translocator. To understand the specific interactions of Vpr-(52-96), the ability of this peptide to dimerize via a leucine-zipper mechanism has been investigated, by NMR and fluorescence spectroscopy. In contrast with results from a study performed in the presence of trifluoroethanol, our results, obtained in 30% (v/v) [2H]acetonitrile, show that Vpr-(52-96) in solution still forms an a-helix spanning residues 53-75, but dimerizes in an antiparallel orientation, through hydrophobic interactions between leucine and isoleucine residues and stacking between His71 and Trp54. Moreover, to demonstrate the physiological relevance of the dimer structure, fluorescence spectroscopy experiments have been performed in a Mes buffer, which confirmed the formation of the dimer in aqueous solution and highlighted the spatial proximity between Trp54 and His71. Surprisingly, the leucine-zipper structure shown in the present work for Vpr-(52-96) mimics the structure of full-length Vpr-(1-96), and this could explain why some of the properties of Vpr-(52-96) and Vpr-(1-96) are identical, while some are even enhanced for Vpr-(52-96), particularly in the case of DNA transfection experiments.
...
PMID:The C-terminal domain of the HIV-1 regulatory protein Vpr adopts an antiparallel dimeric structure in solution via its leucine-zipper-like domain. 1557 93

A sensitive and accurate liquid chromatography-tandem mass spectrometric (LC-MS/MS) method for the intracellular determination of nine antiretroviral drugs in human peripheral blood mononuclear cells (PBMCs) is proposed. PBMCs are isolated by density gradient centrifugation using Vacutainer CPT tubes and cell count is performed with a Coulter instrument. Single-step extraction of drugs from PBMCs pellets is performed with MeOH 50% (with clozapine added as internal standard, I.S.) and the supernatant is injected onto a 2.1 mm x 30 mm SymmetryShield 3.5 microm-RP18 column equipped with a 2.1 x 10 mm guard column. Chromatographic separations are performed using a gradient program with a mixture of 2 mM ammonium acetate containing 0.1% formic acid and acetonitrile with 0.1% formic acid. Analytes quantification is performed by electro-spray ionisation-triple quadrupole mass spectrometry using the selected reaction monitoring (SRM) detection mode. The positive mode is used for the HIV protease inhibitors (PIs) indinavir, amprenavir, saquinavir, ritonavir, nelfinavir, lopinavir, atazanavir and the non-nucleoside reverse transcriptase inhibitors (NNRTIs) nevirapine, and the negative mode is applied for efavirenz. The calibration curves are prepared using blank PBMCs spiked with antiretroviral drugs at concentrations ranging from 0.5 to 100 ng/ml of cell extracts and fitted to a quadratic regression model weighted by 1/(concentration)(2). The lower limit of quantification is less than 0.5 ng/ml. The mean extraction recovery for all PIs/NNRTIs is always above 88%. The method is precise, with mean inter-day CV% within 0.6-10.2%, and accurate (range of inter-day deviation from nominal values -7.2 to +8.3%). This analytical method can be conveniently used in clinical research for the assessment of intracellular levels of all PIs/NNRTIs commercially available at present using a simple one-step cell extraction of PBMCs followed by liquid chromatography coupled with tandem triple quadripole mass detection.
...
PMID:Intracellular measurements of anti-HIV drugs indinavir, amprenavir, saquinavir, ritonavir, nelfinavir, lopinavir, atazanavir, efavirenz and nevirapine in peripheral blood mononuclear cells by liquid chromatography coupled to tandem mass spectrometry. 1583 90

An HPLC-MS/MS assay for the determination of an HIV integrase inhibitor, 5-(1,1-dioxido-1,2-thiazinan-2-yl)-N-(4-fluorobenzyl)-8-hydroxy-1,6-naphthyridine-7-carboxamide (I) in human plasma has been developed and validated. Compound I and a stable isotope labeled internal standard (II) were isolated from 0.5 mL plasma samples by solid phase extraction using an Ansys SPEC C-8 96-well plate. Extracts were separated on a Hypersil BDS C-18 HPLC column (3.0 mmx50 mm, 3 microm) with a mobile phase consisting of 25 mM ammonium formate pH 3.0:acetonitrile (60:40) vol%/vol% pumped at 0.5 mL/min. A Sciex API 365 mass spectrometer equipped with an atmospheric pressure chemical ionization source was operated in selected reaction monitoring (SRM) mode with the precursor-to-product ion transitions m/z 431-->109 (I) and m/z 437-->115 (II) used for quantitation. The assay was validated over the concentration range of 10-5000 ng/mL and was found to have acceptable accuracy, precision, linearity, and selectivity. The mean extraction recovery from spiked plasma samples was 69%. The intra-day accuracy of the assay was within 4% of nominal and intra-day precision was better than 4% C.V. Following a 200 mg dose of the compound administered to human subjects, concentrations of I ranged from 21.1 to 1500 ng/mL in plasma samples collected up to 12 h after dosing. Inter-day accuracy and precision results for quality control samples run over a 3-month period alongside clinical samples showed mean accuracies of within 6% of nominal and precision better than 3.5% C.V.
...
PMID:Determination of an investigational HIV integrase inhibitor in human plasma using high performance liquid chromatography with tandem mass spectrometric detection. 1586 94


<< Previous 1 2 3 4 5 6 7 8 9 10 Next >>