Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: UMLS:C0019270 (hernia)
15,856 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

Abdominal hernia repair is one of the most common surgical procedures. Current data indicate that the best treatment results are achieved with use of synthetic material to reinforce weakened abdominal wall. Prosthetic materials utilized for hernia repair induce adhesions with underlying viscera. They should be therefore separated from them by a layer of peritoneum otherwise adhesions may cause to serious complications such as bowel-skin fistulas. The aim of our work was to determine if implantation of our collagen membrane into abdominal wall defect induce adhesions in rat model of ventral hernia. The collagen film was obtained by acetic acid extraction of rat tail tendons and than casting the soluble fraction onto polyethylene shits. Abdominal wall defect was created in 10 Wistar male rats. Collagen membranes were implanted into the defect using interrupted polypropylene stitches. After 3 months of observation all animals were sacrificed. No adhesions between path structure and bowel developed. In one often rats (10%) adhesion between fixating stitch and omentum was observed. Complete mesothelium lining and vascular ingrowth were microscopically observed within implanted structure. Promising result requires further confirmation in a larger series of animals.
...
PMID:[Abdominal wall reconstruction with collagen membrane in an animal model of abdominal hernia. A preliminary report]. 1913 74

The use of mesh in hernia repair has become common, because of lower recurrence rate and simple application. Data from the meta-analysis and the multi-central studies support the use of meshes in hernia repair. One of the complications due to the hernia repair with mesh is the infection. The incidence range is between 1 and 10%. Triclosan embedded commercial absorbable suture materials are used to reduce surgical site infection rate. This study was planned on mesh infection model, because of the low incidence rate. The agent isolated from mesh infections was mostly Staphylococcus aureus and thus it was used as the infecting agent in this research. To achieve a better therapeutic efficacy, triclosan was formulated in chitosan gels. Chitosan is an attractive biopolymer because of its biocompatible, biodegradable, bioadhesive properties. Gel formulations using chitosans (low, medium and high molecular weight) were prepared in 1% (v/v) acetic acid solution and in vitro release profiles were evaluated. Gel formulations showed release profile extended up to 7 days and high molecular weight chitosan gel formulation was released higher quantity drug than other formulations. Meshes coated with triclosan loaded chitosan gel were used to reduce bacterial count and to prevent mesh infection in the study. 24h and simultaneous bacteria inoculation was used to model mesh infection. The rats were observed for 8 days by means of surgical site infection. On the eighth day, the animals were sacrificed and the grafts were removed. Tissue squeezers were used to liberate bacterias from removed grafts. The isolated suspensions were cultured on blood agar plates and colony-forming units were counted overnight. Grafts coated with triclosan loaded chitosan gel presented satisfactory preventive effect against graft infection.
...
PMID:Antibacterial activity of triclosan chitosan coated graft on hernia graft infection model. 1950 40