Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Pivot Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Target Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Query: UMLS:C0019270 (
hernia
)
15,856
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
Previous studies have indicated that
ethylene glycol
(EG) is a developmental toxicant in rats and mice primarily when ingested. This study was designed to establish no-observed-effect levels (NOELs) for developmental toxicity of EG administered by gavage in both rodent species. Dams were administered EG on Gestation Days 6-15; rats were given 0, 150, 500, 1000, or 2500 mg EG/kg/day; mice were dosed with 0, 50, 150, 500, or 1500 mg EG/kg/day. In rat dams given 2500 mg EG/kg/day, water consumption was increased during treatment and body weights were reduced throughout gestation; liver and kidney weights were increased at euthanization (Gestation Day 21). Relative liver weights were also increased at 1000 mg/kg/day. Effects observed in rat fetuses at 2500 mg/kg/day included the following: hydrocephaly; gastroschisis; umbilical
hernia
; fused, duplicated, or missing arches, centra, and ribs; poor ossification in thoracic and lumbar regions; and reduced body weights. Reduced body weights, duplicated or missing ribs, centra, and arches, and poor ossification were also observed in rat fetuses at 1000 mg/kg/day. In mice, there was no apparent treatment-related maternal toxicity. In mouse fetuses (Gestation Day 18), effects were observed at 1500 mg/kg/day and included reduced body weights, fused ribs and arches, poor ossification in thoracic and lumbar centra, and increased occurrence of an extra 14th rib. At 500 mg/kg/day, slight reductions in fetal body weight and increased incidences of extra ribs were observed. Under conditions of these studies, NOELs for developmental toxicity were 500 mg/kg/day for rats and 150 mg/kg/day for mice, indicating that mice were more susceptible than rats to the teratogenic effects of EG.
...
PMID:Determination of a no-observed-effect level for developmental toxicity of ethylene glycol administered by gavage to CD rats and CD-1 mice. 758 22
Hernia
repair is one of the most common operations in general surgery, and its associated complications typically relate to infections, among others. The loading of antibiotics to surgical meshes to deliver them locally in the abdominal
hernia
repair site can be one way to manage infections associated with surgical implants. However, the amount of drug loaded is restricted by the low wettability of polypropylene (PP). In this work, plasma has been used to tailor the surface properties of PP meshes to obtain high loading of ampicillin while conserving the desired biological properties of the unmodified samples and conferring them with antibacterial activity. It was demonstrated that the new surface chemistry and improved wettability led to 3-fold higher antibiotic loading. Subsequently, a
PEG
-like dry coating was deposited from tetraglyme with low-pressure plasma which allowed maintaining the high drug loading and kept cell properties such as chemotaxis, adhesion and morphology to the same levels as the untreated ones which have shown long-standing clinical success.
...
PMID:Antibiotic-loaded polypropylene surgical meshes with suitable biological behaviour by plasma functionalization and polymerization. 2632 24
Secure closure of the fascial layers after entry into the peritoneal cavity is crucial to prevent incisional
hernia
, yet appropriate purchase of the tissue can be challenging due to the proximity of the underlying protuberant bowel which may become punctured by the surgical needle or strangulated by the suture itself. Devices currently employed to provide visceral protection during abdominal closure, such as the metal malleable retractor and Glassman Visceral Retainer, are unable to provide complete protection as they must be removed prior to complete closure. A puncture resistant, biocompatible, and degradable matrix that can be left in place without need for removal would facilitate rapid and safe abdominal closure. We describe a novel elastomer (CC-DHA) that undergoes a rapid but controlled solid-to-liquid phase transition through the application of a destabilized carbonate cross-linked network. The elastomer is comprised of a polycarbonate cross-linked network of dihydroxyacetone, glycerol ethoxylate, and tri(
ethylene glycol
). The ketone functionality of the dihydroxyacetone facilitates hydrolytic cleavage of the carbonate linkages resulting in a rapidly degrading barrier that can be left in situ to facilitate abdominal fascial closure. Using a murine laparotomy model we demonstrated rapid dissolution and metabolism of the elastomer without evidence of toxicity or intraabdominal scarring. Furthermore, needle puncture and mechanical properties demonstrated the material to be both compliant and sufficiently puncture resistant. These unique characteristics make the biomaterial extraordinarily useful as a physical barrier to prevent inadvertent bowel injury during fascial closure, with the potential for wider application across a variety of medical and surgical applications.
...
PMID:Transient phase behavior of an elastomeric biomaterial applied to abdominal laparotomy closure. 2857 17
The state-of-the-art
hernia
meshes, used in hospitals for
hernia
repair, are predominantly polymeric textile-based constructs that present high mechanical strength, but lack antimicrobial properties. Consequently, preventing bacterial colonization of implanted prosthetic meshes is of major clinical relevance for patients undergoing
hernia
repair. In this study, the co-axial electrospinning technique was investigated for the development of a novel mechanically stable structure incorporating dual drug release antimicrobial action. Core/shell structured nanofibers were developed, consisting of Nylon-6 in the core, to provide the appropriate mechanical stability, and Chitosan/
Polyethylene oxide
in the shell to provide bacteriostatic action. The core/shell structure consisted of a binary antimicrobial system incorporating 5-chloro-8-quinolinol in the chitosan shell, with the sustained release of Poly(hexanide) from the Nylon-6 core of the fibers. Homogeneous nanofibers with a "beads-in-fiber" architecture were observed by TEM, and validated by FTIR and XPS. The composite nanofibrous meshes significantly advance the stress-strain responses in comparison to the counterpart single-polymer electrospun meshes. The antimicrobial effectiveness was evaluated in vitro against two of the most commonly occurring pathogenic bacteria; S. aureus and P. aeruginosa, in surgical site infections. This study illustrates how the tailoring of core/shell nanofibers can be of interest for the development of active antimicrobial surfaces.
...
PMID:Nylon-6/chitosan core/shell antimicrobial nanofibers for the prevention of mesh-associated surgical site infection. 3218 79