2,704 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

Influences of hemoglobin (Hb) variants (HbSS, HbCC, beta-thalassemia, HbAE, HbAS, HbAC, hereditary persistent HbF) and Hb derivatives (carbamylated- and acetylated-Hbs, Schiff base, and those formed in stored blood) on results of glyco-Hb assays by 102 laboratories using 16 different methods were investigated. Affinity chromatography shows deviating results only with homozygous Hb S and C. Correct interpretation of results from patients with decreased erythrocyte half-lives requires previous knowledge on this condition. Measurements of HbA1c by HPLC and electrophoresis are obviously unsuitable for homozygous hemoglobinopathies; for heterozygous hemoglobinopathies and Hb synthesis variants, HbA1c should be expressed as percentage of HbA0 + HbA1c; abnormal Hbs are usually recognized; both carbamylated- and acetylated-Hbs interfere and Schiff base must be eliminated. Except for stored blood, all Hb variants and derivatives gave erroneous results with disposable ion-exchange columns. Dako's immunoassay is not affected by Hb derivatives; glycated Hb variants are not recognized as glyco-Hb and percentages are consequently too low. Glyco-Hb by the immunoassay of Bayer (performed by one laboratory) is not affected by Hb variants and derivatives.
...
PMID:Influence of hemoglobin variants and derivatives on glycohemoglobin determinations, as investigated by 102 laboratories using 16 methods. 768 46

The monitoring of diabetic patients by evaluating glycated protein levels is now widely accepted and performed. The microchromatographic version of the high performance liquid chromatography method is the technique most frequently used in clinical practice. The DCA 2000 instrument (Bayer Diagnostics, Milan, Italy), based on an immunochemical technique, has been proposed for the rapid and simple evaluation of HbAlc, using even capillary blood. We evaluated 171 subjects including 22 healthy volunteers, 78 type 2 diabetic patients with different degrees of metabolic control, 11 women affected by gestational diabetes mellitus (GDM), 6 patients with hyperlipemia, 38 patients with chronic renal failure, 13 diabetic patients with chronic renal failure, and 3 patients with hemoglobinopathies. The DCA 2000 model was compared with the Diamat HPLC system. Data from within-run imprecision studies showed excellent precision, for both DCA 2000 and the HPLC system. The correlation between the two different systems, as shown by other statistical evaluations, was good (y = 0.911x + 0.462, r = 0.923). Results from the control group and diabetic patients were used to compare the two methods. Values obtained using the DCA 2000 were significantly lower (p < 0.0001) than those obtained with the HPLC system, in both healthy subjects and diabetic patients. To detect possible interferences, selected samples were analyzed from patients with hyperlipemia, diabetes and chronic renal failure, and hemoglobinopathies. While in the case of hyperlipemia, an acceptable correlation coefficient between the two systems was confirmed (y = 1.047x - 1.236, r = 0.876), in the case of chronic renal failure the correlation turned out to be very low (y = 0.254x + 3.456, r = 0.203). Our results indicate that the DCA 2000 gives accurate and reliable results in the clinical field of interest.
...
PMID:Evaluation of diagnostic reliability of DCA 2000 for rapid and simple monitoring of HbA1c. 1092 29

Automated cell counters are widely used in modern clinical laboratories to provide reliable, fast, and cost-effective complete blood counts (CBCs), white blood cell differentials, and reticulocyte measurements. In addition, some advanced instruments provide novel parameters, such as the hemoglobin content of reticulocytes or the percentage of hypochromic cells, and are capable of analysis of a variety of body fluids. Bayer recently introduced the ADVIA 2120 system as an automation-ready cell counter for mid- to high-volume testing in the clinical laboratory. This instrument, which builds on the established technology of the ADVIA 120 system, operates with a cyanide-free method for hemoglobin measurement, has a new user interface, and can routinely analyze biological fluid samples in addition to blood. We used 749 samples from 6 worldwide trial sites to evaluate the clinical performance of this new device. Accuracy of the ADVIA 2120 system versus its predecessor model, the ADVIA 120 system, was excellent for all CBC and white cell differential parameters and reticulocyte counts (all correlation coefficients except for basophils >0.9). Correlation of the white cell differential with the standard manual method and within-run precision of the ADVIA 2120 system also was very good. Use of the novel cyanide-free method for hemoglobin measurement had no clinically significant impact on hemoglobin results, even in patients with hemoglobinopathies. We concluded that the ADVIA 2120 system has clinically equivalent performance to the ADVIA 120 system.
...
PMID:Performance evaluation of the ADVIA 2120 hematology analyzer: an international multicenter clinical trial. 1579 May 54