Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: UMLS:C0018801 (heart failure)
72,216 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

Functional mitral regurgitation in heart failure limits survival in a severity-graded fashion. Even mild mitral regurgitation doubles mortality risk. We report the use of a non-stented coronary sinus device to reduce mitral annulus dimension in order to re-establish mitral valve competence. The device (PTMA, Viacor, Inc., Wilmington, MA, USA) consists of a multi-lumen PTFE (Teflon) PTMA catheter in which Nitinol (nickel-titanium alloy) treatment rods are advanced. For individual use up to three rods of different length and stiffness can be used. Therefore dimension reduction can be performed in an incremental fashion. Fluoroscopy and 3 D echocardiography are performed throughout the procedure to visiualize the positioning and confirm maximum treatment effect. The case describes the use and the effect of PTMA treatment. Safety and efficacy of the PTMA device will be investigated in the upcoming PTOLEMY 2 trial.
...
PMID:Percutaenous mitral valve: A non-stented coronary sinus device for the treatment of functional mitral regurgitation in heart failure patients. 1943 Oct 68

Functional mitral regurgitation (MR) in heart failure patients limits survival in a severity-graded fashion. Even mild MR doubles the mortality risk. The use of a nonstented coronary sinus device to reduce mitral annulus dimension in order to reestablish mitral valve competence is reported. The device (PTMA, Viacor, Inc., Wilmington, MA, USA) consists of a multilumen PTFE (Teflon) PTMA catheter in which nitinol (nickel-titanium alloy) treatment rods are advanced. For individual treatment, up to three rods of different length and stiffness can be used. Therefore, dimension reduction can be performed in an incremental fashion. Fluoroscopy and three-dimensional (3-D) echocardiography are performed through the procedure to visualize the positioning and confirm maximum treatment effect. This report describes an implant case and summarizes the safety and feasibility of the new PTMA treatment device in 27 patients. The cases reflect the learning curve in both device design and implantation technique. In permanent implant, a sustained reduction of mitral annulus septal-lateral dimension from 3-D echo reconstruction dimensions was observed (4.9 +/- 1.2 mm at 3 months).
...
PMID:[Percutaneous mitral annuloplasty with the VIACOR coronary sinus system for the treatment of functional mitral regurgitation in heart failure patients. Development and results]. 1978 65