Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: UMLS:C0018799 (heart disease)
34,133 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

The six-minute walk test (6-MWT) is widely used to assess functional status in patients with chronic heart failure (CHF). The aims of the present study were: (1) to compare metabolic gas exchange during the 6-MWT in older patients with left ventricular systolic dysfunction (LVSD) and in breathless patients with no major structural heart disease (MSHD); (2) to determine the exercise intensity of the 6-MWT relative to peak oxygen uptake; (3) to establish the accuracy and reproducibility of the Metamax 3B ergospirometer during an incremental workload. Twenty four older patients with LVSD (19 male; age 76 +/- 5 years; BMI 27 +/- 4), and 18 patients with no MSHD (12 male; age 75 +/- 8 years; BMI 27 +/- 4) attended on consecutive days at the same time. Patients completed a 6-MWT with metabolic gas exchange measurements using the Metamax 3B portable ergospirometer, and an incremental cycle ergometry test using both the Metamax 3B and Oxycon Pro metabolic cart. Patients returned and performed a second 6-MWT and an incremental treadmill test, metabolic gas exchange was measured with the Metamax 3B. In patients with LVSD, the 6-MWT was performed at a higher fraction of maximal exercise capacity (p = 0.02). The 6-MWT was performed below the anaerobic threshold in patients with LVSD (83 %) and in patients with no MSHD (61 %). The Metamax 3B showed satisfactory to high accuracy at 10 W and 20 W in patients with LVSD (r = 0.77 - 0.97, p < 0.05), and no MSHD (r = 0.76 - 0.94, p < 0.05). Metabolic gas exchange variables measured during the 6-MWT showed satisfactory to high day-to-day reproducibility in patients with LVSD (ICC = 0.75 - 0.98), but a higher variability was evident in participants with no MSHD (ICC = 0.62 - 0.97). The Metamax 3B portable ergospirometer is an accurate and reproducible device during submaximal, fixed rate exercise in older patients with LVSD and no MSHD. In elderly patients with LVSD and no MSHD, the 6-MWT should not be considered a maximal test of exercise capacity but rather a test of submaximal exercise performance. Our study demonstrates that the 6-MWT takes place at a higher proportion of peak oxygen uptake in patients with LVSD compared to those with no MSHD, and may be one reason why fatigue is a more prominent symptom in these patients.
...
PMID:Cardiorespiratory requirements of the 6-min walk test in older patients with left ventricular systolic dysfunction and no major structural heart disease. 1743 92

The validity and reproducibility of echocardiographic methods used to quantify mitral regurgitation (MR) in children with congenital heart disease are unknown. We evaluated the usefulness of methods used to quantify MR in children enrolled in a multicenter trial of enalapril 6 months after surgical repair of an atrioventricular septal defect (AVSD). MR severity in this trial was assessed using body surface area (BSA)-adjusted vena contracta lateral (i-VCW(lat)) and anterior-posterior (i-VCW(ap)) dimensions and cross-sectional area (i-VCA), regurgitant volume/BSA, regurgitant fraction, and qualitative MR grade. For each method, association with left ventricular end-diastolic volume (LVEDVz) and end-diastolic dimension (LVEDDz) z-scores and interobserver agreement were assessed. In 149 children (median age 1 year), i-VCW(lat), i-VCW(ap), and i-VCA were best associated with LVEDVz (r (2) = 0.54, r (2) = 0.24, and r (2) = 0.46, respectively; p < 0.001 for all) and showed the highest interobserver agreement (intraclass correlation coefficient = 0.62, 0.73, and 0.68, respectively). Qualitative MR grade was also associated with LVEDVz (r (2) = 0.31, p < 0.001) and showed modest interobserver agreement (kappa 0.56). Regurgitant volume/BSA and regurgitant fraction were associated with LVEDVz (r (2) = 0.45 and r (2) = 0.45, p < 0.001 for both) but showed poor interobserver agreement [ICC = 0.28 (n = 91) and ICC = 0.17 (n = 76), respectively], and their values were negative in 75% of subjects. In conclusion, echocardiographic assessment of MR severity after AVSD remains challenging. Among the quantitative methods used in this trial, i-VCW and i-VCA performed the best but offered little advantage compared with qualitative MR grade. The utility of regurgitant volume and fraction was severely limited by poor interobserver agreement and frequently negative values.
...
PMID:Challenges in echocardiographic assessment of mitral regurgitation in children after repair of atrioventricular septal defect. 2190 74

Ophthalmic surgery would a surgical practice with fewer complications compared to other types of surgery. This is only true in part, because of the elderly population of reference. So, in cataract surgery we are faced with a patient with heart disease which carries the signs of aging and degenerative consequences linked to it. The interventions performed in patients with heart disease are still potentially have a greater risk, although site preparation and monitoring during and after surgery in recent years have allowed greater safety for patients and an overall reduction in morbidity and mortality. It is stressed so the importance of a correct clinical diagnosis of the general patient for a better stratification of cardiovascular risk for ophthalmic surgery. It must therefore avoid the most frequent sequelae, such as the ICC, arrhythmias and hypertensive crises. One purpose of a Service of Internal Medicine, like ours, totally dedicated to the functional requirements of the assistance of ophthalmologic patients, both during hospitalization, and in prehospitalization, and especially in Day Hospital and in Day Service, for the cardiac risk stratification in ophthalmic surgery, is to ensure firstly to the patient and then to colleagues ophthalmologist and surgeons and anesthetists the greater security on the plane predictive for reducing perioperative and postoperative morbidity and mortality.
...
PMID:[Internal medicine and cardiovascular evaluation of preoperative and perioperative patients undergoing ophthalmic surgery]. 2421 32

The purpose of this study was to assess the criterion validity of existing accelerometer-based energy expenditure (EE) prediction equations among children with chronic conditions, and to develop new prediction equations. Children with congenital heart disease (CHD), cystic fibrosis (CF), dermatomyositis (JDM), juvenile arthritis (JA), inherited muscle disease (IMD), and hemophilia (HE) completed 7 tasks while EE was measured using indirect calorimetry with counts determined by accelerometer. Agreement between predicted EE and measured EE was assessed. Disease-specific equations and cut points were developed and cross-validated. In total, 196 subjects participated. One participant dropped out before testing due to time constraints, while 15 CHD, 32 CF, 31 JDM, 31 JA, 30 IMD, 28 HE, and 29 healthy controls completed the study. Agreement between predicted and measured EE varied across disease group and ranged from (ICC) .13-.46. Disease-specific prediction equations exhibited a range of results (ICC .62-.88) (SE 0.45-0.78). In conclusion, poor agreement was demonstrated using current prediction equations in children with chronic conditions. Disease-specific equations and cut points were developed.
...
PMID:Validation of Accelerometer Prediction Equations in Children with Chronic Disease. 2618 89