Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: UMLS:C0016382 (flushing)
6,387 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

The patient was a 60-year-old Japanese male. He complained of epigastralgia and right chest pain of 4 month's duration, and general malaise, nausea and vomiting of 2 month's duration. Physical examination revealed on the right third rib a tender mass with a diameter of 2 cm and hepatomegaly with a multi-nodular surface and red palms. There were no signs of carcinoid syndrome, such as cutaneous flushing. Laboratory examinations disclosed certain biochemical alterations; alkaline phosphatase 810 IU/l, gamma-glutamyl transpeptidase (gamma-GTP) 2090 IU/l, carcinoembryonic antigen (CEA) 23.5 ng/ml and alpha-fetoprotein (AFP) 6,800 ng/ml. Both HBs-Ag and HBs-Ab were negative. The patient died in a uremic state, with rapid increases of jaundice and ascites. Autopsy revealed gastric carcinoid with extensive metastases to the liver and the bone marrow. Tumor cells showed argyrophilia but not argentaffinity. Immunofluorescence specific for AFP was positive in the hepatocytes, particularly those adjacent to the metastatic tumor cells but not in the tumor cells, either primary or secondary. 79 cases reported in Japan of serum AFP-positive malignant tumor other than hepatocellular carcinoma and certain other malignancies of germ cell origin are reviewed and discussed.
...
PMID:Serum alpha-fetoprotein-positive gastric carcinoid with liver metastasis. 616 67

An integrated microfluidic device with injecting, flushing, and sensing functions was realized using valves that operate based on direct electrowetting. The device consisted of two substrates: a glass substrate with driving and sensing electrodes and a poly(dimethylsiloxane) (PDMS) substrate. Microfluidic transport was achieved using the spontaneous movement of solutions in hydrophilic flow channels formed with a dry-film photoresist layer. The injection and flushing of solutions were controlled by gold working electrodes, which functioned as valves. The valves were formed either in the channels or in a through-hole in the glass substrate. To demonstrate the system's applicability to an immunoassay, the detection of immobilized antigens was performed as a partial simulation of a sandwich immunoassay. Human alpha-fetoprotein (AFP) or an anti-human AFP antibody was immobilized on a platinum working electrode in the chamber using a plasma-polymerized film (PPF). By applying a potential to the injection valves, necessary solutions were injected one by one through the channels into a reaction chamber at the center of the chip and incubated for reasonable periods of time. The solutions were then flushed through the flushing valve and absorbed in a filter paper placed under the device. After incubation with the corresponding antibodies labeled with glucose oxidase (GOD), electrochemical detection was conducted. In both cases, the obtained current depended on the amount of immobilized antigen. The calibration curves were sigmoidal, and the detection limit was 0.1 ng. The developed microfluidic system could potentially be a fundamental component for a micro immunoassay of the next generation.
...
PMID:Electrochemical immunoassay on a microfluidic device with sequential injection and flushing functions. 1738 71