Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: UMLS:C0016382 (flushing)
6,387 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

A method for characterization of the melanin biopolymer has been developed and validated by the use of synthetic melanins derived from tyrosine, dopamine or hydroquinone. The technique involved pyrolysis gas-liquid chromatography with capillary columns. A back-flushing technique is described which improves pyrogram reproducibility such that closely related melanins can be distinguished with the aid of principal components analysis and non-metric multidimensional scaling.
...
PMID:Characterization of biopolymers by pyrolysis gas chromatography and multidimensional analysis. Application to synthetic melanins. 355 55

The performance of capillaries coated with a poly(diallyldimethylammonium) (PDADMA) monolayer or poly(diallyldimethylammonium)-poly(styrenesulfonate) bilayer was investigated and compared under micellar electrokinetic chromatographic (MEKC) conditions. Both monolayer (positively charged) and bilayer (negatively charged) coatings with micellar (sodium dodecyl sulfate) electrolyte generated very stable and pH-independent cathodal electroosmotic flow (EOF). From the results obtained, it can be concluded that in a doubly coated capillary the second poly(styrenesulfonate) layer is replaced by sodium dodecyl sulfate micelles during flushing with micellar electrolyte. Consequently, in order to obtain a stable and pH-independent cathodal electroosmotic flow for the MEKC separations, the capillary coating with the second polyanion layer is not necessary. The importance of the PDADMA coating was illustrated by comparing MEKC separations of the common developing agents (hydroquinone, phenidone, pyrocatechol, pyrogallol and quinone) on a bare uncoated capillary with the coated capillary. The coating provides reproducible MEKC separations at low pH (pH 3.0) with relative standard deviation (R.S.D.) values for migration times and peak areas lower than 0.45 and 3.3%, respectively. Good linearities in the range from 5 x 10(-5) to 2 x 10(-3) mol l(-1) were obtained for all five compounds, with correlation coefficients higher than 0.998. The detection limits were in the range from 5 x 10(-6) mol l(-1) for pyrocatechol to 2 x 10(-5) mol l(-1) for quinone. The proposed MEKC system was applied to the determination of hydroquinone and phenidone in X-ray photographic developer solutions.
...
PMID:Micellar electrokinetic chromatography at low pH with polyelectrolyte-coated capillaries. 1529 6