Query: UMLS:C0014118 (
endocarditis
)
15,629
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
Long-term performance of Starr-Edwards silastic ball (SESB, n = 168) and St Jude Medical bi-leaflet (SJMB, n = 93) valves in patients who were alive 30 days after implantation (1980-86) for aortic stenosis was compared. Mean follow-up was 3.0 years (0.1-7.9 years). The SESB and SJMB groups differed as regards female gender (18% vs 47%, P less than 0.0001), NYHA classes III-IV (59% vs 72%, P less than 0.05), coronary artery disease (
CAD
, 32% vs 62%, P less than 0.01) in patients with coronary arteriography (n = 82 and n = 55, respectively), and prosthetic annulus diameter (26 +/- 1 vs 23 +/- 2 mm, P less than 0.0001). Five-year survival +/- SE in SESB vs SJMB patients was: total population, 89 +/- 3% vs 80 +/- 6% (NS); coronary arteriography population, no
CAD
, 90 +/- 4% vs 100% (NS), and with
CAD
, 71 +/- 11% vs 60 +/- 13% (NS; P = 0.01 for
CAD
). Five-year event-free survival +/- SE in SESB vs SJMB patients was 95 +/- 2% vs 97 +/- 2% (NS) for thromboembolism, 95 +/- 2% vs 89 +/- 4% (NS) for coumadin-related haemorrhage, 98 +/- 1% vs 99 +/- 1% (NS) for
endocarditis
, 98 +/- 1% vs 94 +/- 5% (NS) for paravalvular leak, 88 +/- 3% vs 79 +/- 6% (NS) for all valve-related complications, and 98 +/- 1% vs 95 +/- 4% (NS) for prosthesis replacement. Thrombotic occlusion or structural failure were not observed. No patients without
CAD
experienced thromboembolic events. Cox regression analyses (in both total population and coronary arteriography population) of survival as well as the various complications revealed that the type of prosthesis did not have predictive influence.
CAD
was an independent risk factor for thromboembolism, haemorrhage, and all valve-related complications. Previous systemic hypertension was independently predictive of haemorrhage. The SESB and SJMB prostheses showed comparable and acceptable long-term performance. Only patient-related variables, notably
CAD
, influenced late results. The proven durability and relatively low price of the SESB valves together with the excellent haemodynamic performance of even small-sized SJMB valves should be considered in the light of the present results.
...
PMID:Long-term performance of Starr-Edwards silastic ball valves and St Jude Medical bi-leaflet valves. A comparative analysis of implantations during 1980-86 for aortic stenosis. 231 12
Between 1.6.1991 and 31.5.1995, 62 patients underwent heart valve replacement with Sorin Bicarbon bileaflet prosthetic valve, age 16-83 years (mean 60.5). The valve disease was rheumatic in 37 cases, degenerative in 17, congenital in 4 and miscellaneous etiologies in the other 4. The valve lesion was AS in 24 patients, AR in 5, AR+MS in 2, MS in 13, MR+MS in 6, MR in 6, tricuspid prosthetic stenosis in 1, A+M disease in 3, and a clotted prosthetic valve (Sorin disc) in 1.
CAD
was present in 14 patients (23%) and AF in 19 (31%). 11 had moderate pulmonary hypertension and 4 severe. Preoperatively 6 patients were in FC II, 40 in FC III and 16 in FC IV. Operative procedures included AVR 18, AVR+CABG 13, AVR+T annuloplasty 1, AVR and open M valvotomy 1, MVR 7, MVR+T annuloplasty 7, MVR+AVR (Medtronic) 1, MVR+AVR 1, TVR, prosthetic valve replacement 1, and MVR+CABG 1. Hospital mortality was 3 (4.8%) -- one due to ruptured A-V groove and two due to LoCO. Postoperative complications: LoCO necessitating IABP -- 3 patient; 3 transient CVA and 1 CVA with hemiplegia. One patient had aortic prosthetic valve
endocarditis
18 months following the operation necessitating reoperation. Other cases were treated for positive blood cultures. One patient had CVA after anticoagulant were discontinued. 28 patients are in FC I, 22 in H, 4 in III and 1 in IV. 4 patients are lost to follow-up. These data suggest that the Sorin Bicarbon Prosthetic valve can be safely and effectively used for heart valve replacement.
...
PMID:Early experience with the Sorin bileaflet prosthetic valve. 1006 47