Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Pivot Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Target Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Query: UMLS:C0012739 (
disseminated intravascular coagulation
)
8,673
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
X-ray imaging offers a new 3-D view into cells. With its ability to penetrate whole hydrated cells it is ideally suited for pairing fluorescence light microscopy and nanoscale X-ray tomography. In this paper, we describe the X-ray optical set-up and the design of the cryo full-field transmission X-ray microscope (TXM) at the electron storage ring BESSY II. Compared to previous TXM set-ups with zone plate condenser monochromator, the new X-ray optical layout employs an undulator source, a spherical grating monochromator and an elliptically shaped glass capillary mirror as condenser. This set-up improves the spectral resolution by an order of magnitude. Furthermore, the partially coherent object illumination improves the contrast transfer of the microscope compared to incoherent conditions. With the new TXM, cells grown on flat support grids can be tilted perpendicular to the optical axis without any geometrical restrictions by the previously required pinhole for the zone plate monochromator close to the sample plane. We also developed an incorporated fluorescence light microscope which permits to record fluorescence, bright field and
DIC
images of cryogenic cells inside the TXM. For TXM tomography, imaging with multi-keV X-rays is a straightforward approach to increase the depth of focus. Under these conditions phase contrast imaging is necessary. For soft X-rays with shrinking depth of focus towards 10nm spatial resolution, thin optical sections through a thick specimen might be obtained by deconvolution X-ray microscopy. As alternative 3-D X-ray imaging techniques, the confocal cryo-STXM and the dual beam cryo-
FIB
/STXM with photoelectron detection are proposed.
...
PMID:Cryo X-ray microscope with flat sample geometry for correlative fluorescence and nanoscale tomographic imaging. 2227 40
In order to discover the mechanism of Xuebijing oral effervescent tablet (XBJOET) to treat infectious diseases, the effect of XBJOET on endotoxin induced rabbit fever and
disseminated intravascular coagulation
(
DIC
) was investigated. Auricle microcirculation in rabbit was detected by laser speckle blood perfusion imager system; coagulation function was measured by coagulation analyzer, fibrinolytic system was quantified by Elisa assay and micro thrombosis in tissues was observed with HE staining under light microscope. The results demonstrated that the body temperature of rabbit decreased significantly at 1-3 h after administration with 4.8, 2.4 and 1.2 g x kg(-1) XBJOET to endotoxin induced
DIC
rabbit model, the auricle microcirculation blood flow in model group (54.45 +/- 14.53) PU was lower than that in control group (77.18 +/- 12.32) PU. The auricle microcirculation blood flow increased markedly and there was significant difference between model group and 1.2 g x kg(-1) XBJOET group. There was significant difference between model group and control group in the content of PAI1 and
FIB
. The PAI1 levels in model and control groups were (30.48 +/- 2.46) ng x mL(-1) and (20.93 +/- 3.25) ng x mL(-1), respectively. The
FIB
levels in model and control group were (3.34 +/- 1.09) g x L(-1) and (4.84 +/- 1.10) g x L(-1), respectively. The content of PAI1 in rabbit plasma decreased notably, there were significant differences between model group and 4.8, 2.4 g x kg(-1) XBJOET groups. On the contrary the content of
FIB
increased. XBJOET possessed pharmacological activities of curing infectious fever and
DIC
, the mechanism of which is related to amelioration of microcirculation disturbance, inhibition of fibrinolytic system activation and coagulation and micro thrombosis elimination.
...
PMID:[Effect of xuebijing oral effervescent tablet on endotoxin induced fever and disseminated intravascular coagulation rabbit model]. 2418 30