Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: UMLS:C0011854 (type 1 diabetes)
20,749 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

Levels of nonantigen-induced pro-inflammatory cytokines and prostaglandin in macrophages isolated from human leucocyte antigen (HLA)-matched type 1 diabetes mellitus patients, first-degree relatives and healthy controls were determined. We hypothesize that monocytes isolated from patients are sensitized or preactivated and therefore, have an altered response to in vitro stimulus compared with control groups as measured by levels of pro- and anti-inflammatory mediators. In this study, peripheral blood monocytes were differentiated to macrophages with macrophage-colony stimulating factor (M-CSF) to determine lipopolysaccharide (LPS)-stimulated tumour necrosis factor (TNF)-alpha, interleukin (IL)-1beta, IL-6, IL-12 and prostaglandin E-2 (PGE-2) secretion from hetero- or homozygous HLA DQB1*0201 and *0302 type 1 diabetes mellitus patients, first-degree relatives and homozygous HLA DQB1*0602 healthy controls. LPS-stimulated secretion of TNF-alpha, IL-1beta and IL-6 was immediate and markedly higher in the HLA-DQB1*0201/*0302 type 1 diabetes patients compared with all other groups including HLA-matched healthy first-degree relatives. In DQB1*0201/*0302 diabetes patients PGE-2 secretion was delayed but increased by LPS stimulation compared with HLA-matched healthy relatives. IL-12 was not detected at any condition. These data suggest that macrophages from DQB1*0201/*0302 type 1 diabetes patients are sensitized to secrete both cytokines and PGE-2 following nonantigenic stimulation. Sensitized macrophages may be important to high-risk DQB1*0201/*0302-associated type 1 diabetes.
...
PMID:Macrophages from high-risk HLA-DQB1*0201/*0302 type 1 diabetes mellitus patients are hypersensitive to lipopolysaccharide stimulation. 1241 Aug 3

The combination of continuous glucose monitoring (CGM) and continuous subcutaneous insulin infusion can be used to improve the treatment of patients with diabetes. The aim of this study was to advance an existing preclinical single-port system for clinical application by integrating the sensors of a phosphorescence based CGM system into a standard insulin infusion set. The extracorporeal optical phase fluorimeter was miniaturised and is now comparable with commercial CGM systems regarding size, weight and wear comfort. Sensor chemistry was adapted to improve the adhesion of the sensor elements on the insulin infusion set. In-vitro tests showed a linear correlation of R2=0.998 between sensor values and reference glucose values in the range of 0-300mg/dl. Electrical and cytotoxicity tests showed no negative impact on human health. Two single-port devices were tested in each of 12 patients with type 1 diabetes mellitus in a clinical set-up for 12h. Without additional data processing, the overall median absolute relative difference (median ARD) was 22.5%. For some of the used devices the median ARD was even well below 10%. The present results show that individual glucose sensors performance of the single-port system is comparable with commercial CGM systems but further improvements are needed. The new system offers a high extent of safety and usability by combining insulin infusion and continuous glucose measurement in a single-port system which could become a central element in an artificial pancreas for an improved treatment of patients with type 1 diabetes mellitus.
...
PMID:First application of a transcutaneous optical single-port glucose monitoring device in patients with type 1 diabetes mellitus. 2755 63