Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Pivot Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Target Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Query: UMLS:C0010200 (
cough
)
23,843
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
The patient was a 59-year-old man with a 5-month history of
cough
, difficulty breathing, and palpitations while working. Initial examination at the internal medicine department of our hospital in August 1992 revealed a mass in the left side of the neck, and he was admitted for further examination and treatment. Preoperative investigations revealed a cystic lesion extending from the left neck area to the mediastinum. The mass was resected on August 13, 1992. Based on the intraoperative findings and postoperative histological examination, a diagnosis of thoracic duct cyst was made. The postoperative course was good and the patient was discharged after two weeks. This is extremely rare case, and the
Trap
door surgical approach proved useful for resection.
...
PMID:[Thoracic duct cyst--a case report]. 875 96
The analytical performance of a fieldable cylindrical ion trap (CIT)-based miniature mass spectrometer is described. A detailed description of the instrument itself is to be found in the immediately preceding paper (Patterson, G. E.; Guymon, A. J.; Riter, L S.; Everly, M.; Griep-Raming, J.; Laughlin, B. C.; Ouyang, Z.; Cooks, R. G., Miniature Cylindrical Ion
Trap
Mass Spectrometer, Anal. Chem. 2002, 24, 6145-6153). Applications employing the MS/MS and MSn capabilities of the miniature instrument and analytical performance criteria are given here. The limit of detection for methyl salicylate, introduced as the pure vapor, is estimated as 1 pg. The resolution, R = m/delta m, where delta m, measured as full width at half-maximum, is estimated as 100. Monitoring of organic compounds in air is performed using a permeation membrane introduction device coupled to the mass spectrometer. Water monitoring is performed using an external membrane introduction mass spectrometry (MIMS) system, with acetophenone and toluene serving as model compounds. Data are given for chemical warfare agent simulants, methyl salicylate, and dimethyl methyl phosphonate (DMMP) in air. On-line detection of menthol vapor emitted from a
cough
drop is reported. Methyl salicylate in air gives a recognizable mass spectrum at 400 ppb in the ambient system, while use of a heated membrane brings the detection limit down to 10 ppb.
...
PMID:Analytical performance of a miniature cylindrical ion trap mass spectrometer. 1251 Jul 33