Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Pivot Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Target Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Query: UMLS:C0008031 (
chest pain
)
17,248
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
Human albumin has the ability to bind cobalt at the N-terminus. The exposure of circulating albumin to ischemic tissue alters the ability of albumin to bind cobalt, probably through a mechanism involving free-radical production. The Albumin
Cobalt
Binding (ACB) test measures the alteration in albumin metal binding, and elevation of the ACB test is thought to be an early indicator of myocardial ischemia. In a previous multicenter study of
chest pain
patients presenting to the emergency department (ED), this test demonstrated high negative predictive value and sensitivity in the sample collected at presentation for predicting cardiac troponin I (cTnI)-negative or cTnI-positive results 6-24 h later. Since the completion of that report, the European Society of Cardiology (ESC) and the American College of Cardiology (ACC) have redefined the criteria for the diagnosis of acute myocardial infarction (AMI). The data from the multicenter ACB study were re-examined using the new diagnostic criteria for AMI to determine if combining the ACB test with troponin improved the sensitivity of either assay used alone for early diagnosis of AMI. Assay values were compared to either the final discharge diagnosis made at each site or to a diagnosis of AMI using the strict application of the ESC/ACC guidelines. Using the criterion of physician's discharge diagnosis and using blood collected at ED presentation, the cTnI test alone had a sensitivity of 23.9%, and the ACB test alone had a sensitivity of 39.1%, but the sensitivity significantly increased to 55.9% (p < 0.001 over cTnI alone) when both tests were used in combination. The sensitivity of the combination of ACB and cTnI tests at the 1- to 6-h time-point was 86.7% and at the >6- to 12-h time-point was 93.5%, but they were not significantly improved over the cTnI test alone. In conclusion, using the new ESC/ACC criteria, the combination also resulted in a statistically significant higher diagnostic sensitivity on blood collected at presentation. These data indicate a possible role of the ACB test in the early triage of patients with
chest pain
.
...
PMID:Analysis of the Albumin Cobalt Binding (ACB) test as an adjunct to cardiac troponin I for the early detection of acute myocardial infarction. 1221 87
The purpose of this study was to validate the Albumin
Cobalt
Binding (ACB) assay at the Seattle Veterans Affairs (VA) Hospital to determine if it would provide an earlier rule-out of acute coronary syndrome (ACS) in patients, compared to current use of cardiac injury markers. This study compares the distribution of ischemia modified albumin (IMA) values of our patient population to those provided by the kit manufacturer. IMA values were determined photometrically on a Roche Modular Analytical System on 200 subjects: 69 subjects not experiencing
chest pain
(normals), 78 subjects presenting to the emergency room (ER) with
chest pain
whose initial and subsequent troponin results were negative (non-converters), and 53 subjects presenting to the ER with
chest pain
whose initial troponin result was negative but subsequent troponin results were positive (converters). Based on the relationships between IMA values in the initial samples from the non-converters and converters, we constructed a ROC curve to identify an optimum IMA rule-out value. The IMA values (mean+/-SD) for the normals, non-converters, and converters were 89+/-7.1, 100+/-13.9, and 126+/-14.1 U/ml, respectively, and each mean was statistically different from the means of the other groups. The ROC curve comparing converters and non-converters showed an area of 0.89 (p <0.001) compared to the line of identity. An IMA cut-off of 97 U/ml gives a 98% sensitivity and 45% specificity and may be the best decision point to differentiate between these groups in our population. Nine of 78 non-converters were classified as having unstable angina. In conclusion, the ACB assay has a strong negative predictive value and sensitivity in our population for predicting the troponin results at 6 to 24 hr post-presentation. Because ACB results may be facility- and instrument-dependent, each facility should conduct an independent ROC analysis to determine the optimal IMA rule-out level. The ACB assay, when used in conjunction with cardiac injury markers and assessment of unstable angina, holds promise in reducing inappropriate low-risk hospital admissions and improving the clinical management of patients with
chest pain
.
...
PMID:Albumin cobalt binding assay to rule out acute coronary syndrome. 1583 Jul 11
The Albumin
Cobalt
Binding Test is a quantitative in vitro diagnostic test used on human serum that detects ischemia-modified albumin by measuring the cobalt binding capacity of albumin in human serum. Ischemia modified albumin is intended for use in conjunction with ECG and cardiac troponin as an aid to short term risk stratification of patients presenting with
chest pain
suggestive of cardiac origin. Thus, in patients with
chest pain
or equivalent symptoms suggestive of cardiac origin, with non-diagnostic ECG and normal troponin, a negative IMA can be used as an aid to rule out acute coronary syndrome (ACS) in low risk patients.
...
PMID:[Ischemia-modified albumin: new marker of myocardial ischemia?]. 1601 13