Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: UMLS:C0008031 (chest pain)
17,248 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

Heart-type fatty acid-binding protein (H-FABP) is a low molecular weight cytoplasmic protein and present abundantly in the myocardium. When the myocardium is injured, as in the case of myocardial infarction, low molecular weight cytoplasmic proteins including H-FABP are released into the circulation and H-FABP is detectable in a blood sample. We have already developed a direct sandwich-ELISA for quantification of human H-FABP using two distinct types of monoclonal antibodies specific for human H-FABP. In this study we investigated the clinical validity of H-FABP as a biochemical diagnostic marker in the early phase of acute myocardial infarction (AMI). To evaluate the diagnostic usefulness of H-FABP in the early phase of AMI, blood samples were obtained from the following patients within 12 hours after the appearance of symptoms, and serum levels of H-FABP were compared with those of conventional diagnostic markers, such as myoglobin and creatine kinase isoenzyme MB (CK-MB). Blood samples were collected from patients with confirmed AMI (n=140), patients with chest pain who were afterwards not classified as AMI by normal CK-MB levels (non-AMI) (n=49) and normal healthy volunteers (n=75). The serum concentration of H-FABP was quantified with our direct sandwich-ELISA. The concentration of myoglobin mass was measured with a commercial RIA kit. The serum CK-MB activity was determined with an immuno-inhibition assay kit. The overall sensitivity of H-FABP, within 12 hours after the appearance of symptoms, was 92.9%, while it was 88.6% with myoglobin and 18.6% with CK-MB. The overall specificity of H-FABP was 67.3%, while it was 57.1% with myoglobin and 98.0% with CK-MB. The diagnostic efficacy rates with these markers were 86.2% (H-FABP), 80.4% (myoglobin) and 39.2% (CK-MB), respectively. The diagnostic validity of H-FABP was further assessed by receiver operating characteristic (ROC) curve analysis. The area under the curve (AUC) of H-FABP was 0.921, which was significantly greater than with myoglobin (AUC: 0.843) and CK-MB (AUC: 0.654). These parameters, such as sensitivity, specificity, diagnostic efficacy and diagnostic accuracy, obtained for patients with chest pain within 3 hours and/or 6 hours after the onset of symptoms were almost the same as those for patients within 12 hours after symptoms. H-FABP is more sensitive than both myoglobin and CK-MB, more specific than myoglobin for detecting AMI within 12 hours after the onset of symptoms, and shows the highest values for both diagnostic efficacy and ROC curve analysis. Thus, H-FABP has great potential as an excellent biochemical cardiac marker for the diagnosis of AMI in the early phase.
...
PMID:Human heart-type cytoplasmic fatty acid-binding protein (H-FABP) for the diagnosis of acute myocardial infarction. Clinical evaluation of H-FABP in comparison with myoglobin and creatine kinase isoenzyme MB. 1090 60

Human heart-type fatty acid-binding protein (FABP) has a high potential as an early marker for myocardial infarction (MI) being more specific than myoglobin. FABP is a low molecular mass cytoplasmic protein (15 kDa) that is released early after the onset of ischemia and it may be useful for rapid confirmation or exclusion of acute myocardial infarction (AMI). Immunochemically assayed FABP, cardiac troponin I (cTnI) and enzymatically assayed creatine phosphokinase (CPK) were determined serially in plasma and serum samples from 218 patients presenting with chest pain and suspected MI. In the 94 patients with confirmed MI, FABP rose to a maximum level (577.6 +/- 43.8 microg/L) 3 hours after the onset of symptoms and returned to normal within 30 hours. The FABP level peaked 7-9 hours earlier than CPK (2288 +/- 131 U/L) and cTnI (357.1 +/- 23.9 microg/L). CPK took 50-70 hours to return to normal level and cTnI returned to normal level over 70 hours. The areas under the receiver operating characteristic (ROC) curves for FABP were calculated as 0.871 at admission and 0.995 one hour after admission, whereas for CPK the areas were 0.711 and 0.856 and for cTnI the areas were 0.677 and 0.845, indicating that the FABP test gave a better diagnostic classification at the early stage being reached by cTnI (0.995) only 8 hours after admission. For FABP, both sensitivity and negative predictive value (NPV) increased quickly to 100% for samples monitored just one hour after admission. By using only two samples, one at admission and one 1 hour post admission, sequential FABP monitoring can reliably diagnose AMI patients 1 hour after admission and 100% of non-AMI patients can be excluded with no false negative results. The late markers cTnI and CPK have the similar diagnostic performance only 7 hours later. Thus measurement of FABP in plasma or serum allows the earliest immunochemical confirmation or exclusion of AMI.
...
PMID:A superior early myocardial infarction marker. Human heart-type fatty acid-binding protein. 1516 Feb 74