Query: UMLS:C0004610 (
bacteremia
)
13,199
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
A total of 6,010 blood culture sets were obtained from adult patients with suspected
bacteremia
or fungemia. The overall recovery of organisms was equivalent in two systems used, BacT/Alert
FAN
medium and BACTEC NR660 Plus 26A medium.
...
PMID:Comparison of BacT/Alert FAN medium with BACTEC NR660 Plus 26A medium. 872 33
Two recent multicenter blood culture studies found that BacT/Alert
FAN
(
FAN
) bottles (Organon Teknika, Durham, N.C.) had increased yields in detecting
bacteremia
and fungemia compared with standard BacT/Alert (STD) bottles. Because the clinical importance of this increase in microbial recovery is unknown, we performed a retrospective analysis to determine the frequency with which
FAN
bottles were the sole means of detecting an episode of
bacteremia
. There were 1,047 positive blood cultures in which both study bottles were adequately filled and the organism isolated was judged to be the cause of sepsis: 240 (23%) were positive only in
FAN
bottles and 73 (7%) were positive only in STD bottles. Of a total of 664 episodes of
bacteremia
, 126 (19%) were identified only by
FAN
bottles and 43 (7%) were identified only by STD bottles (P < 0.0001). Episodes detected only by
FAN
bottles more often were recurrent events (23 of 126, or 18%) than episodes detected only by STD bottles (2 of 43, or 5%) (P < 0.05) and more commonly occurred in patients receiving theoretically effective antibiotic therapy (33 of 126 [26%] versus 4 of 43 [9%]) (P < 0.05). The medical records for patients with 127 of these episodes (92
FAN
bottles only; 35 STD bottles only) were available for review. More than half of both
FAN
bottle-only (60 of 92, or 65%) and STD bottle-only (20 of 35, or 57%) episodes were judged to be clinically important. We conclude that
FAN
bottles improve the detection of
bacteremia
and that the majority of the additional episodes detected are clinically important. The benefits of the greater yield in specific patient populations must be balanced against the higher costs of
FAN
bottles.
...
PMID:Clinical importance of increased sensitivity of BacT/Alert FAN aerobic and anaerobic blood culture bottles. 886 81
We compared the BacT/Alert system using the aerobic
FAN
bottle with the ESP system using the 80A aerobic bottle for the detection of pediatric bloodstream pathogens at a children's hospital. From 6,636 blood culture sets complying with the inclusion criteria, 308 pathogens were detected, including 177 that were detected by both systems, 69 that were detected by BacT/Alert
FAN
only, and 62 that were detected by ESP 80A only (P = 0.6; not significant). BacT/Alert
FAN
detected more isolates of Staphylococcus aureus (47 versus 34; P = 0.02), while ESP 80A detected more episodes of streptococcal and enterococcal infection. BacT/Alert
FAN
detected more pathogens from patients receiving antibiotic therapy (107 versus 93; P = 0.04). Of 248 separate episodes of
bacteremia
or fungemia, 146 were detected by both systems, 56 were detected by ESP 80A only, and 46 were detected by BacT/Alert
FAN
only (P = 0.37; not significant). The median times to detection were 13.6 h for ESP 80A and 15.7 h for BacT/Alert
FAN
(P < 0.001). Both systems were considered easy to operate and were free from significant mechanical difficulties. False-positive or false-negative signals were rare or nonexistent with both systems. We conclude that both systems rapidly detect a broad range of pediatric bloodstream pathogens. BacT/Alert
FAN
provides better detection of Staphylococcus aureus, especially from patients receiving antibiotics. ESP 80A provides better detection of streptococci and enterococci.
...
PMID:Comparison of the BacT/Alert FAN aerobic and the Difco ESP 80A aerobic bottles for pediatric blood cultures. 911 1
Studies have demonstrated that large-volume culture methods for sterile body fluids other than blood increase recovery compared to traditional plated-medium methods. BacT/Alert is a fully automated blood culture system for detecting
bacteremia
and fungemia. In this study, we compared culture in BacT/Alert standard aerobic and anaerobic bottles, BacT/Alert
FAN
aerobic and
FAN
anaerobic bottles, and culture on routine media for six specimen types, i.e., continuous ambulatory peritoneal dialysate (CAPD), peritoneal, amniotic, pericardial, synovial, and pleural fluids. Specimen volumes were divided equally among the three arms of the study. A total of 1,157 specimens were tested, with 227 significant isolates recovered from 193 specimens. Recovery by method was as follows: standard bottles, 186 of 227 (82%);
FAN
bottles, 217 of 227 (96%); and routine culture, 184 of 227 (81%). The
FAN
bottles recovered significantly more gram-positive cocci (P < 0.001), Staphylococcus aureus (P = 0.003), coagulase-negative staphylococci (P = 0.008), gram-negative bacilli (P < 0.001), Enterobacteriaceae (P = 0.005), and total organisms (P < 0.001) than the routine culture. There were no significant differences in recovery between the standard bottles and the routine culture. The
FAN
aerobic bottle recovered significantly more gram-positive cocci (P < 0.001), S. aureus isolates (P < 0.001), coagulase-negative staphyococci (P = 0.003), and total organisms (P < 0.001) than the standard aerobic bottle, while the
FAN
anaerobic bottle recovered significantly more gram-positive cocci (P < 0.001), S. aureus isolates (P < 0.001), Enterobacteriaceae (P = 0.03), and total organisms (P < 0.001) than the standard anaerobic bottle. For specific specimen types, significantly more isolates were recovered from the
FAN
bottles compared to the routine culture for synovial (P < 0.001) and CAPD (P = 0.004) fluids. Overall, the
FAN
bottles were superior in performance to both the standard bottles and the routine culture for detection of microorganisms from the types of sterile body fluids included in this study.
...
PMID:Use of the BacT/Alert blood culture system for culture of sterile body fluids other than blood. 977 78
A total of 9,130 blood cultures were collected from adult patients with suspected bloodstream infections. The recommended 20 mL sample of blood was divided equally between the aerobic and anaerobic
FAN
bottles and monitored in the BacT/Alert Microbial Detection System for a total of 5 days. There were 757 clinically significant positive culture pairs from 291 patients. Significant differences were found with greater recovery of Pseudomonas aeruginosa (p < 0.001), Acinetobacter spp. (p = 0.002), coagulase-negative staphylococci other than Staphylococcus epidermidis (p = 0.002), and Candida spp. (p < 0.001) from the aerobic bottle and greater recovery of anaerobic bacteria (p < 0.001) from the anaerobic bottle. Significantly more episodes of P. aeruginosa
bacteremia
(p < 0.003) and candidemia (p < 0.001) were detected by the aerobic
FAN
bottle and significantly more episodes of anaerobic
bacteremia
(p < 0.001) were detected by the anaerobic
FAN
bottle (Table 2). No other significant differences between systems in their detection of bacteremias were noted. Anaerobic bacteremias were encountered in diverse and often unpredictable clinical settings. All clinically significant episodes of bloodstream infection were detected within 4 days of incubation of their cultures. We conclude routine, rather than selective, use of the anaerobic
FAN
bottle in the blood culture set and a 4-day incubation of blood cultures in the BacT/Alert aerobic and anaerobic
FAN
bottles is an appropriate routine procedure.
...
PMID:Reassessment of the routine anaerobic culture and incubation time in the BacT/Alert FAN blood culture bottles. 1057 87
Few laboratory microbiological procedures are as important as the isolation of microorganisms from blood. To evaluate the usefulness of the terminal subcultures, 5669 blood cultures giving negative results after 7 days of incubation in the Bact/Alert System (Organon Teknika) were studied. Bottles were distributed as follows: 1562 adult aerobic bottles, 119 adult anaerobic bottles, 3960 pediatric bottles and 28
FAN
bottles. From 5669 blood cultures, 10 subcultures that yielded growth had not been detected by the system. These included 5 adult aerobic bottles and 5 pediatric bottles, 7 of these microorganisms were considered contaminants according to clinical data (2 Micrococcus spp, 1 staphylococci coagulase negative, 1 Burkholderia cepacia, 1 Peptoestreptococcus spp, 1 Corynebacterium spp, 1 Scedosporium spp) while the other 3 were considered true
bacteremia
(1 Pseudomonas aeruginosa, 1 Proteus mirabilis, 1 Streptococcus sanguis), although no one made any change in treatment on the basis of the previous isolation. Based on these results the routinary utilization of terminal subcultures is not advisable and should be used only for special cases or a second system of blood culture should be added according to clinical or epidemiological data.
...
PMID:[Bact-Alert system for hemocultures: evaluation of terminal subcultures]. 1114 51
Yeasts are an increasingly common cause of nosocomial bloodstream infections. Methods for their detection are many; controlled comparisons are few. The vented
FAN
aerobic blood culture medium has been shown to be superior to the standard BacT/ALERT aerobic medium for the detection of fungemia as well as
bacteremia
. The BACTEC selective fungal medium (FM) (BD Biosciences, Sparks, Md.) allowed detection of more episodes of fungemia than did a resin-containing medium with equal volumes of blood cultured. Therefore, we compared vented
FAN
to FM for the ability to recover fungi from the blood of patients who were at increased risk of having fungemia. From 5,109 cultures processed for which both
FAN
and FM bottles were adequately filled, fungi were recovered from 87 cultures. Of these, 47 were detected with both bottles, 12 were detected with
FAN
only, and 28 were detected with FM only (P < 0.05).
FAN
was the first bottle positive for 36 of the 47 cultures for which both bottles yielded the same fungus, whereas the FM bottle was the first bottle positive for 11 cultures (P < 0.001). A total of 54 episodes of fungemia were identified, with 40 detected by both media, 4 detected only by
FAN
, and 10 detected only by FM (P value, not significant). We conclude that the vented
FAN
aerobic bottle is comparable to the FM bottle for detection of episodes of yeast infection but has the added benefit of detecting bacteria.
...
PMID:Controlled comparison of BacT/ALERT FAN aerobic medium and BATEC fungal blood culture medium for detection of fungemia. 1115 18
Blood culture is the most valuable laboratory test for the diagnosis of
bacteremia
and sepsis. The BACTEC FX and BacT/Alert 3D automated blood culture systems are commonly used in Korean health care facilities. A controlled clinical evaluation of the resin-containing BACTEC Plus aerobic (BA) and anaerobic (BN), and the charcoal-containing
FAN
aerobic (FA) and anaerobic (FN) bottles using blood from intensive care unit (ICU) patients was designed. The performances of these 2 systems with media containing particle absorbing antimicrobial agents were evaluated using the culture positivity rate and time to detection (TTD). TTD was collected using data management systems, either the Epicenter (BD Diagnostic Systems) or the hospital laboratory information system. A total of 1539 four-bottle sets were collected from 270 patients in medical and surgical ICUs. Blood culture samples included 1539 bottles each of BA, BN, FA, and FN, and yielded 113 (7.3%), 90 (5.8%), 104 (6.8%), and 80 (5.2%) positive bacterial or fungal isolates, respectively. There were significant differences between the resin-containing BA and BN samples in culture positivity and also between the charcoal-containing FA and FN samples, especially for Escherichia coli (25/27 versus 17/27, P < 0.05) and Acinetobacter baumannii (14/15 versus 7/15, P < 0.05). Significantly shorter recovery time was observed in BACTEC Plus aerobic bottles than in
FAN
aerobic bottles (17.2 and 24.7 h, respectively) (P < 0.001).
...
PMID:Evaluation of BACTEC Plus aerobic and anaerobic blood culture bottles and BacT/Alert FAN aerobic and anaerobic blood culture bottles for the detection of bacteremia in ICU patients. 2254 87
Assays that expedite the reporting of organism identification and antibiotic susceptibility status in positive blood cultures can fast track interventions that improve clinical outcomes. We evaluated the Verigene Gram-positive blood culture nucleic acid test (BC-GP) in two pediatric hospitals. Positive BacT/Alert Pediatric
FAN
blood cultures with Gram-positive organisms were tested using the BC-GP in tandem with routine laboratory procedures. To test organisms underrepresented in the clinical blood culture evaluation, blood culture bottles were spiked with diluted organism suspensions at concentrations of 10 to 100 CFU per milliliter. A total of 249 Gram-positive bacterial isolates were recovered from 242 blood cultures. The BC-GP detected Staphylococcus aureus, methicillin-susceptible S. aureus, and methicillin-resistant S. aureus with sensitivities of 100%, 99%, and 100% and specificities of 100%, 100%, and 99.5%, respectively. The BC-GP detected Staphylococcus epidermidis, methicillin-susceptible S. epidermidis, and methicillin-resistant S. epidermidis with sensitivities of 95%, 80%, and 96%, respectively, and 100% specificity. The BC-GP correctly identified 14/15 cases of Enterococcus faecalis and Enterococcus faecium
bacteremia
and 9 cases of Streptococcus pneumoniae. It misidentified 5/15 clinical blood cultures with Streptococcus mitis/Streptococcus oralis and 1/3 blood cultures spiked with Streptococcus anginosus group as S. pneumoniae. The BC-GP detected a case of Streptococcus pyogenes
bacteremia
but failed to detect 2/3 clinical blood cultures with Streptococcus agalactiae. BC-GP's rapid accurate detection of Staphylococcus spp., E. faecium, and E. faecalis and its ability to ascertain mecA, vanA, and vanB status may expedite clinical decisions pertaining to optimal antibiotic use. False-positive S. pneumoniae results may warrant reporting of only "Streptococcus spp." when this organism is reported by the BC-GP.
...
PMID:Rapid detection of Gram-positive organisms by use of the Verigene Gram-positive blood culture nucleic acid test and the BacT/Alert Pediatric FAN system in a multicenter pediatric evaluation. 2396 84
Here, we compare the sensitivities and times to detection (TTD) of BacT/Alert Pediatric
FAN
(PF) and Bactec Peds Plus blood culture bottles. Test bottles were inoculated with 2 ml of banked whole blood, 1-ml aliquots of antibiotic suspension, and organisms diluted to simulate a
bacteremia
level of 10 to 100 CFU/ml. The control bottles were inoculated with 3 ml of banked blood and organism suspensions only. The organism-drug combinations were Staphylococcus epidermidis and vancomycin, methicillin-resistant Staphylococcus aureus and vancomycin, Streptococcus pneumoniae, vancomycin, and ceftriaxone, Streptococcus agalactiae, ampicillin, and cefotaxime, Escherichia coli, cefotaxime, and cefepime, Pseudomonas aeruginosa, piperacillin-tazobactam, cefepime, and gentamicin, Neisseria meningitidis and ceftriaxone, and Haemophilus influenzae and ceftriaxone. The control and test bottle combinations were tested in duplicate. The bottles were incubated for 5 days; 32 control and 104 test bottles were incubated. Overall, the bacterial recovery rates for the PF and Peds Plus bottles were 37% and 62%, 94% and 100% in the controls, 19% and 50% in the test bottles, and 33% and 92% in the bottles with vancomycin, respectively. No bacteria were recovered from the bottles with S. pneumoniae, S. agalactiae, E. coli, N. meningitidis, or H. influenzae in combination with cefotaxime or ceftriaxone. The Peds Plus system detected P. aeruginosa in bottles with cefepime and piperacillin-tazobactam, but the PF system recovered bacteria only in bottles with trough levels of piperacillin-tazobactam. The mean TTD were shorter in the Peds Plus system controls (14.2 versus 18.0 h; P = 0.001) and the test bottles (14.3 versus 17.8 h; P = 0.008) than in the PF bottles. Overall, we demonstrated superior sensitivity, TTD, and antibiotic neutralization in the Bactec Peds Plus system compared to those in the Pediatric
FAN
system.
...
PMID:Superior sensitivity and decreased time to detection with the Bactec Peds Plus/F system compared to the BacT/Alert Pediatric FAN blood culture system. 2408 54