Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: UMLS:C0004135 (ATM)
13,001 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

Obstructive sleep apnea (OSA) is a common sleep disorder that often remains undiagnosed, leading to an increased risk of developing cardiovascular diseases. Polysomnogram (PSG) is currently used as a golden standard for screening OSA. However, because it is time consuming, expensive and causes discomfort, alternative techniques based on a reduced set of physiological signals are proposed to solve this problem. This study proposes a convenient non-parametric kernel density-based approach for detection of OSA using single-lead electrocardiogram (ECG) recordings. Selected physiologically interpretable features are extracted from segmented RR intervals, which are obtained from ECG signals. These features are fed into the kernel density classifier to detect apnea event and bandwidths for density of each class (normal or apnea) are automatically chosen through an iterative bandwidth selection algorithm. To validate the proposed approach, RR intervals are extracted from ECG signals of 35 subjects obtained from a sleep apnea database ( http://physionet.org/cgi-bin/atm/ATM ). The results indicate that the kernel density classifier, with two features for apnea event detection, achieves a mean accuracy of 82.07 %, with mean sensitivity of 83.23 % and mean specificity of 80.24 %. Compared with other existing methods, the proposed kernel density approach achieves a comparably good performance but by using fewer features without significantly losing discriminant power, which indicates that it could be widely used for home-based screening or diagnosis of OSA.
...
PMID:An obstructive sleep apnea detection approach using kernel density classification based on single-lead electrocardiogram. 2573 75

The photoplethysmographic (PPG) signal measures the local variations of blood volume in tissues, reflecting the peripheral pulse modulated by cardiac activity, respiration, and other physiological effects. Therefore, PPG can be used to extract the vital cardiorespiratory signals like heart rate (HR), and respiratory rate (RR) and this will reduce the number of sensors connected to the patient's body for recording these vital signs. In this paper, we propose an algorithm based on ensemble empirical mode decomposition with principal component analysis (EEMD-PCA) as a novel approach to estimate HR and RR simultaneously from PPG signal. To examine the performance of the proposed algorithm, we used 310 (from 35 subjects) and 632 (from 42 subjects) epochs of simultaneously recorded electrocardiogram, PPG, and respiratory signal extracted from MIMIC (Physionet ATM data bank) and Capnobase database, respectively. Results of EEMD-PCA-based extraction of HR and RR from PPG signal showed that the median RMS error (1st and 3rd quartiles) obtained in MIMIC data set for RR was 0.89 (0, 1.78) breaths/min, for HR was 0.57 (0.30, 0.71) beats/min and in Capnobase data set it was 2.77 (0.50, 5.9) breaths/min and 0.69 (0.54, 1.10) beats/min for RR and HR, respectively. These results illustrated that the proposed EEMD-PCA approach is more accurate in estimating HR and RR than other existing methods. Efficient and reliable extraction of HR and RR from the pulse oximeter's PPG signal will help patients for monitoring HR and RR with low cost and less discomfort.
...
PMID:Ensemble Empirical Mode Decomposition With Principal Component Analysis: A Novel Approach for Extracting Respiratory Rate and Heart Rate From Photoplethysmographic Signal. 2828 94