Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: UMLS:C0002986 (Fabry)
5,646 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

Herein we report the label-free detection of a cancer biomarker using newly developed arrayed nanostructured Fabry-Perot interferometer (FPI) microchips. Specifically, the prostate cancer biomarker free prostate-specific antigen (f-PSA) has been detected with a mouse anti-human PSA monoclonal antibody (mAb) as the receptor. Experiments found that the limit-of-detection of current nanostructured FPI microchip for f-PSA is about 10 pg/mL and the upper detection range for f-PSA can be dynamically changed by varying the amount of the PSA mAb immobilized on the sensing surface. The control experiments have also demonstrated that the immunoassay protocol used in the experiments shows excellent specificity and selectivity, suggesting the great potential to detect the cancer biomarkers at trace levels in complex biofluids. In addition, given its nature of low cost, simple-to-operation and batch fabrication capability, the arrayed nanostructured FPI microchip-based platform could provide an ideal technical tool for point-of-care diagnostics application and anticancer drug screen and discovery.
...
PMID:Nanostructured optical microchips for cancer biomarker detection. 2277 Sep 4

Robot-assisted surgical procedures, taking advantage of the high soft tissue contrast and real-time imaging of magnetic resonance imaging (MRI), are developing rapidly. However, it is crucial to maintain tactile force feedback in MRI-guided needle-based procedures. This paper presents a Fabry-Perot interference (FPI) based system of an MRI-compatible fiber optic sensor which has been integrated into a piezoelectrically actuated robot for prostate cancer biopsy and brachytherapy in 3T MRI scanner. The opto-electronic sensing system design was minimized to fit inside an MRI-compatible robot controller enclosure. A flexure mechanism was designed that integrates the FPI sensor fiber for measuring needle insertion force, and finite element analysis was performed for optimizing the correct force-deformation relationship. The compact, low-cost FPI sensing system was integrated into the robot and calibration was conducted. The root mean square (RMS) error of the calibration among the range of 0-10 Newton was 0.318 Newton comparing to the theoretical model which has been proven sufficient for robot control and teleoperation.
...
PMID:A Fabry-Perot Interferometry Based MRI-Compatible Miniature Uniaxial Force Sensor for Percutaneous Needle Placement. 2512 53