Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: UMLS:C0002736 (amyotrophic lateral sclerosis)
19,048 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

The interactions of an imidazolium based ionic liquid (IL), namely 1-dodecyl-3-methylimidazolium chloride [C12 mim][Cl] with two sulfonated anionic dyes, azocarmine G and methyl orange, are studied spectrophotometrically in both acidic and basic media. ILs (with some surface active character) can interact with the above dyes and cause considerable shifts in their spectra. These interactions are then compared with some surfactant-dye interactions. Evolving factor analysis (EFA) and multivariate curve resolution-alternating least squares (MCR-ALS) are used for complete resolution of the measured spectrophotometric data. The concentration and spectral profiles of all species were calculated without any assumption of the chemical models. The spectral variation of dye solutions as a function of IL concentrations below and above the critical aggregation concentration (CAC) is analyzed using MCR-ALS as a soft-modeling technique. The ion pair formation constants between ILs and dyes were calculated using the obtained concentration profiles.
...
PMID:Interaction of anionic dyes and cationic surfactants with ionic liquid character. 1840 16

Multivariate curve resolution using alternating least squares (MCR-ALS) was used to quantify ascorbic (AA) and acetylsalicylic (ASA) acids in four pharmaceutical samples using a flow injection analysis (FIA) system with pH gradient and a diode array (DAD) spectrometer as a detector. Four different pharmaceutical drugs were analyzed, giving a data array of dimensions 51 x 291 x 61, corresponding respectively to number of samples, FIA times and spectral wavelengths. MCR-ALS was applied to these large data sets using different constraints to have optimal resolution and optimal quantitative estimations of the two analytes (AA and ASA). Since both analytes give an acid-basic pair of species contributing to the UV recorded signal, at least four components sholuld be proposed to model AA and ASA in synthetic mixture samples. Moreover, one additional component was needed to resolve accurately the Schlieren effect and another additional component was also needed to model the presence of possible interferences (like caffeine) in the commercial drugs tablets, giving therefore a total number of 6 independent components needed. The best quantification relative errors were around 2% compared to the reference values obtained by HPLC and by the oxidation-reduction titrimetric method, for ASA and AA respectively. In this work, the application of MCR-ALS allowed for the first time the full resolution of the FIA diffusion profile due to the Schlieren effect as an independent signal contribution, suggesting that the proposed MCR-ALS method allows for its accurate correction in FIA-DAD systems.
...
PMID:Multivariate curve resolution of pH gradient flow injection mixture analysis with correction of the Schlieren effect. 1849 79

This review explores the question whether chemometrics methods enhance the performance of electroanalytical methods. Electroanalysis has long benefited from the well-established techniques such as potentiometric titrations, polarography and voltammetry, and the more novel ones such as electronic tongues and noses, which have enlarged the scope of applications. The electroanalytical methods have been improved with the application of chemometrics for simultaneous quantitative prediction of analytes or qualitative resolution of complex overlapping responses. Typical methods include partial least squares (PLS), artificial neural networks (ANNs), and multiple curve resolution methods (MCR-ALS, N-PLS and PARAFAC). This review aims to provide the practising analyst with a broad guide to electroanalytical applications supported by chemometrics. In this context, after a general consideration of the use of a number of electroanalytical techniques with the aid of chemometrics methods, several overviews follow with each one focusing on an important field of application such as food, pharmaceuticals, pesticides and the environment. The growth of chemometrics in conjunction with electronic tongue and nose sensors is highlighted, and this is followed by an overview of the use of chemometrics for the resolution of complicated profiles for qualitative identification of analytes, especially with the use of the MCR-ALS methodology. Finally, the performance of electroanalytical methods is compared with that of some spectrophotometric procedures on the basis of figures-of-merit. This showed that electroanalytical methods can perform as well as the spectrophotometric ones. PLS-1 appears to be the method of practical choice if the %relative prediction error of approximately +/-10% is acceptable.
...
PMID:Does chemometrics enhance the performance of electroanalysis? 1879 Jan 14

A new analytical method based on Fourier transformed infrared spectroscopy (FTIR) using chemometric tools to treat spectral data is proposed to study the degradation of aqueous phenolic solutions by photo-Fenton process. Obtained results were validated by high-performance liquid chromatography (HPLC) taken as a reference method. First a discrimination of the different steps of phenol degradation was possible by applying a principal component analysis (PCA). Then a description of the reaction evolution was successfully made using MCR-ALS, a multivariate curve resolution method which has permitted to obtain the concentration profiles of phenol and its photoproducts. Kinetics of their formation and disappearance described with this new approach are in agreement with HPLC results. This methodology may be a good alternative to classical analyses for monitoring of the degradation reactions because a lot of data are recorded and treated simultaneously. It shows how species concentration varies over time, informing thus on the reaction mechanism because a structural identification of products is possible through pure extracted spectra.
...
PMID:FTIR-multivariate curve resolution monitoring of photo-Fenton degradation of phenolic aqueous solutions. Comparison with HPLC as a reference method. 1880 21

The overall purpose of the project, of which this study is a part, was to examine the feasibility of onion waste as a support-substrate for the profitable production of food-grade products. This study focused on the efficient production of ethanol from worthless onions by transforming the onion juice into onion liquor via alcoholic fermentation with the yeast Saccharomyces cerevisiae. The onion bioethanol produced could be later used as a favorable substrate for acetic fermentation to finally obtain onion vinegar. Near-infrared spectroscopy (NIRS), coupled with the multivariate curve resolution-alternating least squares (MCR-ALS) method, has been used to reveal the compositional and spectral profiles for both substrates and products of alcoholic fermentation runs, that is, total sugars, ethanol, and biomass concentration. The ambiguity associated with the ALS calculation was resolved by applying suitable inequality and equality constraints. The quality of the results provided by the NIR-based MCR-ALS methodology adopted was evaluated by several performance indicators, including the variance explained by the model, the lack of fit and the agreement between the MCR-ALS achieved solution and the results computed by applying previously validated PLS reference models. An additional fermentation run was employed to test the actual predictive ability of the ALS model developed. For all the components resolved in the fermentation system studied (i.e., total sugars, ethanol, and biomass), the final model obtained showed a high predictive ability and suitable accuracy and precision, both in calibration and external validation, confirmed by the very good agreement between the ALS responses and the reference values (the coefficient of determination was, in all cases, very close to 1, and the statistics confirmed that no significant difference was found between PLS reference models and the MCR-ALS methodology applied). Thus, the proven reliability of the MCR-ALS model presented in this study, based only on NIR measurements, makes it suitable for monitoring of the key species involved in the alcoholic fermentation of onion juice, allowing the process to be modeled and controlled in real time.
...
PMID:Valorization of onion waste and by-products: MCR-ALS applied to reveal the compositional profiles of alcoholic fermentations of onion juice monitored by near-infrared spectroscopy. 1881 97

The effect of the pH (from 3 to 10) on the excitation emission matrices (EEMs) of fluorescence of CdTe quantum dots (QDs), capped with mercaptopropionic acid (MPA), were analyzed by multiway decomposition methods of parallel factor analysis (PARAFAC), a variant of the parallel factor analysis method (PARAFAC2) and multivariate curve resolution alternating least squares (MCR-ALS). Three different sized CdTe QDs with emission maximum at 555 nm (QDa), 594 nm (QDb) and 628 nm (QDc) were selected for analysis. The three-way data structures composed of sets of EEMs obtained as function of the pH (EEMs, pH) do not have a trilinear structure. A marked deviation to the trilinearity is observed in the emission wavelength order--the emission spectra suffers wavelength shift as the pH is varied. The pH-induced variation of the fluorescence properties of QDs is described with only one-component PARAFAC2 or MCR-ALS models--other components are necessary to model scattering and/or other background signals in (EEMs, pH) data structures. Bigger sized QDs are more suitable tools for analytical methodologies because they show higher Stokes shifts (resulting in simpler models) and higher pH range sensitivity. The pH dependence of the maximum wavelength of the emission spectra is particularly suitable for the development of QDs/EEMs wavelength-encoded pH sensor bioimaging or biological label methodologies when coupled to multiway chemometric decomposition.
...
PMID:Multiway chemometric decomposition of EEM of fluorescence of CdTe quantum dots obtained as function of pH. 1892 2

We evaluate the contribution made by multivariate curve resolution-alternating least squares (MCR-ALS) for resolving gel permeation chromatography-Fourier transform infrared (GPC-FT-IR) data collected on butadiene rubber (BR) and styrene butadiene rubber (SBR) blends in order to access in-depth knowledge of polymers along the molecular weight distribution (MWD). In the BR-SBR case, individual polymers differ in chemical composition but share almost the same MWD. Principal component analysis (PCA) gives a general overview of the data structure and attests to the feasibility of modeling blends as a binary system. MCR-ALS is then performed. It allows resolving the chromatographic coelution and validates the chosen methodology. For SBR-SBR blends, the problem is more challenging since the individual elastomers present the same chemical composition. Rank deficiency is detected from the PCA data structure analysis. MCR-ALS is thus performed on column-wise augmented matrices. It brings very useful insight into the composition of the analyzed blends. In particular, a weak change in the composition of individual SBR in the MWD's lowest mass region is revealed.
...
PMID:Contribution made by multivariate curve resolution applied to gel permeation chromatography-Fourier transform infrared data for an in-depth characterization of styrene-butadiene rubber blends. 1893 30

We applied a multiway approach to extract information from the analysis of protein isoforms by CE-ESI-MS. Metallothioneins (MT) are low-molecular-weight proteins (6-7 kDa) with a strong affinity for heavy-metal ions. Rabbit liver MT-I and MT-II fractions are purified from MT samples. At low pH, the bound metal ions were released from the amino acid structures, giving rise to apothioneins. MT-I, MT-II and MT apothioneins, which are complex mixtures of protein isoforms, were analyzed by CE-ESI-MS. After data pre-processing, parallel factor analysis (PARAFAC) and multivariate curve resolution-alternating least squares (MCR-ALS) were applied to the data sets. In both cases, the models enabled classification of the protein samples and identification of their characteristic sub-isoforms using a set of three components. MCR-ALS required an initial estimate of the pure mass spectra of the three components. Thus, PARAFAC loadings were used to initialize the MCR-ALS optimization. The classifications obtained with MCR-ALS were slightly better than those obtained with PARAFAC, probably because MCR-ALS was less affected by the small migration time shifts of the pre-processed electropherograms. However, no differences were found between the pure mass spectra of the three components in either model. Finally, MCR-ALS allowed us to obtain an individual electrophoretic profile of each of the three components for each of the samples analyzed, which proved valuable for characterization and quantification purposes.
...
PMID:A multiway approach for classification and characterization of rabbit liver apothioneins by CE-ESI-MS. 1901 64

A differential pulse polarographic (DPP) study of the Pb(2+)/Cys-Gly, Pb(2+)/gamma-Glu-Cys, Pb(2+)/PC(2) and Pb(2+)/PC(3) systems is performed, being PC(2) and PC(3) the phytochelatins of general structure (gamma-Glu-Cys)(n)-Gly, with n=2 and 3, respectively. Analysis of DPP data is assisted by multivariate curve resolution with alternating least squares (MCR-ALS) method in order to establish the complexes formation sequence and their final stoichiometries. DPP signals of these systems present, besides overlapping of peaks due to free metal ion and metal complexes, interference of mercury anodic signals. Despite these complications, MCR-ALS allows us to propose a model of complexation for each system, and some tentative structures for the complexes.
...
PMID:Soft modelling for the resolution of highly overlapped voltammetric peaks: application to some Pb-phytochelatin systems. 1907 10

Use of Multivariate Curve Resolution Alternating Least Squares (MCR-ALS) is evaluated in the analysis of nine phenolic acids, both in standards mixture samples and in strawberry juice samples, by liquid chromatography with diode array detection (LC-DAD). Chromatographic coelution problems either because of unknown matrix interferences or because of the increase of organic modifier to reduce chromatographic analysis times are investigated. pH (4.25) and proportion of organic modifier in acetonitrile-water ratios (11:89, v/v) used as mobile phases have been optimized for separation of mixture of nine phenolic acids. Results obtained in the resolution and quantitation of phenolic acids in standards mixture samples and strawberry samples at two proportions of organic modifier (11:89 and 40:60 acetonitrile-water (v/v) ratios) show that the proposed MCR-ALS approach reduces analysis times and solvent expenses and improves determinations in case of strong coelution. Limits on the use of MCR-ALS are investigated in the analysis of phenolic acids in strawberry samples.
...
PMID:Determination of phenolic acids in strawberry samples by means of fast liquid chromatography and multivariate curve resolution methods. 1907 75


<< Previous 1 2 3 4 5 6 7 8 9 10 Next >>