Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Pivot Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Target Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Query: UMLS:C0002736 (
amyotrophic lateral sclerosis
)
19,048
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
Accelerate oxidative degradation of six vegetable oils was monitored using FTIR and FT-Raman spectroscopy. Two-dimensional correlation spectroscopy and multivariate curve resolution alternating least squares (MCR-ALS) were applied to the analysis of the data. The use of hetero-spectral two-dimensional correlation of FTIR and FT-Raman data allowed the use of well established band assignments to interpret less clearly assigned spectral features. With a moving window approach it was possible to obtain simplified two-dimensional correlation maps and to detect compounds evolving with different kinetic. Simultaneous analysis of the oxidation experiments of the six different oils monitored by both spectroscopic techniques was performed using
MCR
-
ALS
. Although a complete resolution of the data was not possible, the spectral changes occurring during the oxidative degradation of the oils were described with a five-component model. The two fundamentally different chemometric approaches lead to coincident results.
...
PMID:Two-dimensional correlation spectroscopy and multivariate curve resolution for the study of lipid oxidation in edible oils monitored by FTIR and FT-Raman spectroscopy. 1753 24
Flow-through low-pressure chromatographic separations capitalized on the sequential injection chromatographic (SIC) concept are for the first time coupled to second-order multivariate regression models based on multivariate curve resolution-alternating least-squares (MCR-ALS) for outperforming current chromatographic methods in terms of resolution efficiency. The proposed SIC-
MCR
-
ALS
method involving sequential injection separation on short monolithic columns along with isocratic elution fosters ultrafast reversed-phase separations of complex multicomponent mixtures regardless of peak overlapping and retention parameters. The ruggedness of SIC systems is enhanced by removing the solenoid valves from the flow network, thus diminishing the column back pressure effects. As a consequence, the flow setup admitted mobile-phase flow rates much higher than those traditionally enabled in SIC. To ascertain the improved peak capacity of the SIC-
MCR
-
ALS
procedure, five phenolic species commonly used in disinfectant products and featuring similar UV spectra and close retention times in short reversed-phase silica-based monolithic phases are selected as model compounds and determined in just 1 min using mobile-phase flow rates of >or=2 mL min(-1). Notwithstanding the fact that the five phenolic derivatives coelute in a single chromatographic band, thus rendering resolution values ranging from 0.05 to 1.11, the concentration profiles and the pure spectra of each individual phenol species could be concurrently obtained. Quantitative validation of the chromatographic-chemometric method demonstrated both the reliability of the results and the enhanced resolution of mixtures with regard to former SIC systems with no need for thorough optimization of the separation conditions.
...
PMID:Coupling of sequential injection chromatography with multivariate curve resolution-alternating least-squares for enhancement of peak capacity. 1785 60
Discussed in this paper is the development of a new strategy to improve resolution of overlapping CE peaks by using second-order multivariate curve resolution with alternating least square (second-order
MCR
-
ALS
) methods. Several kinds of organic reagents are added, respectively, in buffers and sets of overlapping peaks with different separations are obtained. Augmented matrix is formed by the corresponding matrices of the overlapping peaks and is then analyzed by the second-order
MCR
-
ALS
method in order to use all data information to improve the precision of the resolution. Similarity between the resolved unit spectrum and the true one is used to assess the quality of the solutions provided by the above method. 3,4-Dihydropyrimidin-2-one derivatives (DHPOs) are used as model components and mixed artificially in order to obtain overlapping peaks. Three different impurity levels, 100, 20, and 10% relative to the main component, are used. With this strategy, the concentration profiles and spectra of impurities, which are no more than 10% of the main component, can be resolved from the overlapping peaks without pure standards participant in the analysis. The effects of the changes in the components spectra in the buffer with different organic reagents on the resolution are also evaluated, which are slight and can thus be ignored in the analysis. Individual data matrices (two-way data) are also analyzed by using
MCR
-
ALS
and heuristic evolving latent projections (HELP) methods and their results are compared with those when
MCR
-
ALS
is applied to augmented data matrix (three-way data) analysis.
...
PMID:Application of Multivariate curve resolution-alternating least square methods on the resolution of overlapping CE peaks from different separation conditions. 1794 Nov 18
The effect of piecewise direct standardization (PDS) and baseline correction approaches was evaluated in the performance of multivariate curve resolution (
MCR
-
ALS
) algorithm for the resolution of three-way data sets from liquid chromatography with diode-array detection (LC-DAD). First, eight tetracyclines (tetracycline, oxytetracycline, chlorotetracycline, demeclocycline, methacycline, doxycycline, meclocycline and minocycline) were isolated from 250 mL effluent wastewater samples by solid-phase extraction (SPE) with Oasis MAX 500 mg/6 mL cartridges and then separated on an Aquasil C18 150 mm x 4.6mm (5 microm particle size) column by LC and detected by DAD. Previous experiments, carried out with Milli-Q water samples, showed a considerable loss of the most polar analytes (minocycline, oxitetracycline and tetracycline) due to breakthrough. PDS was applied to overcome this important drawback. Conversion of chromatograms obtained from standards prepared in solvent was performed obtaining a high correlation with those corresponding to the real situation (r2 = 0.98). Although the enrichment and clean-up steps were carefully optimized, the sample matrix caused a large baseline drift, and also additive interferences were present at the retention times of the analytes. These problems were solved with the baseline correction method proposed by Eilers.
MCR
-
ALS
was applied to the corrected and uncorrected three-way data sets to obtain spectral and chromatographic profiles of each tetracycline, as well as those corresponding to the co-eluting interferences. The complexity of the calibration model built from uncorrected data sets was higher, as expected, and the quality of the spectral and chromatographic profiles was worse.
...
PMID:Solving matrix-effects exploiting the second order advantage in the resolution and determination of eight tetracycline antibiotics in effluent wastewater by modelling liquid chromatography data with multivariate curve resolution-alternating least squares and unfolded-partial least squares followed by residual bilinearization algorithms I. Effect of signal pre-treatment. 1809 3
Nimesulide, a Cox-2 inhibitor anti-inflammatory drug, is a light sensitive compound and its biological activity is decreased upon photodegradation. The photodegradation kinetic of nimesulide was investigated spectrophotometrically using multivariate curve resolution analysis to overcome spectral overlapping of reactant and degradation products. The absorbance spectra of the nimesulide methanolic solution, exposed to daily sunlight, were recorded at different times. Three absorbing chemical species, coexisted in the reaction system, were detected by application of factor analysis to the absorbance data matrix. The soft-modeling multivariate curve resolution-alternative least square (MCR-ALS) analysis of the evolutionary absorbance data revealed that nimesulide undergoes photodegradation through a two-step consecutive manner, where both steps obey first-order kinetic. By application of the kinetic hard model constraint to the
MCR
-
ALS
analysis, an excellent agreement was obtained between the fitted concentration profiles and those obtained by soft method. The first-order rate constants of the first and second degradation products were calculated as 0.052 (+/-0.007) and 0.009 (+/-0.001)h(-1), respectively. Finally, the pure spectra of the resolved chemical species were calculated, where that of nimesulide was the same as that obtained experimentally.
...
PMID:Spectrophotometric monitoring of nimesulide photodegradation by a combined hard-soft multivariate curve resolution-alternative least square method. 1832 16
Excitation emission fluorescence matrices (EEMs) of Verapamil drug were obtained by direct and by derivatization fluorescence spectroscopy. The fluorescence excitation and emission wavelengths were displaced to longer wavelengths and the fluorescence intensity was enhanced upon derivation with respect to the native fluorescence of the drug. The complete EEM of the native fluorescence of the drug and of the derivatization product were rapidly acquired by using a charged-coupled device detector (CCD), which is advantageous in terms of speed in the analysis, with respect to the use of a conventional photomultiplier detector. The EEMs were analyzed by several second-order multivariate calibration methods exploiting the second order advantage. The three-dimensional decomposition methods used, based in different assumptions about the trilinearity of the three way data structure under analysis, were parallel factor analysis (PARAFAC), bilinear least squares (BLLS), parallel factor analysis 2 (PARAFAC2) and multivariate curve resolution-alternating least squares (MCR-ALS). The determination was performed by using the standard addition approach. The figures of merit of the PARAFAC and BLLS methods were calculated, obtaining a lower limit of detection with the derivatization procedure, when compared with the direct measurement of the fluorescence of the drug. In Verapamil drug the best estimations were found with the BLLS and the
MCR
-
ALS
models. In the quantification of Verapamil in a pharmaceutical formulation the best estimation, when compared with the result obtained by the US Pharmacopeia high performance liquid chromatography approach, was obtained by direct fluorescence spectroscopy with
MCR
-
ALS
and by derivatization fluorescence spectroscopy with the PARAFAC2 model.
...
PMID:Optimization of Verapamil drug analysis by excitation-emission fluorescence in combination with second-order multivariate calibration. 1833 Jun 81
The interaction of a new derivative of thiazole orange (TO-3) with calf thymus DNA (ctDNA) has been investigated by fluorescence and absorption spectroscopy. When TO-3 binds to ctDNA, absorption bands exhibit significant hypochromicity at low base pair/dye ratio (BP/D ratio), and high BP/D show hyperchromicity with red shift. The spectral changes are attributed to the different species formed between TO-3 and ctDNA in the titration course of the dye molecule with DNA. Multivariate curve resolutions-alternating least squares (MCR-ALS) is applied to the absorption measurements recorded to recover the concentration profiles and the pure spectra of the DNA/TO-3 complexes involved in the process. The binding constant and size of the binding site have been determined spectrophotometrically using the McGhee von Hippel equation.
MCR
-
ALS
has been used to reveal the precise concentration profiles of all detectable species formed between ctDNA and TO-3 and their pure spectral profiles.
...
PMID:Spectroscopic characterization of thiazole orange-3 DNA interaction. 1835 Mar 83
Application of multivariate curve resolution alternating least squares (MCR-ALS), for the resolution and quantification of different analytes in different type of pharmaceutical and agricultural samples is shown. In particular,
MCR
-
ALS
is applied first to the UV spectrophotometric quantitative analysis of mixtures of commercial steroid drugs, and second to the near-infrared (NIR) spectrophotometric quantitative analysis of humidity and protein contents in forage cereal samples. Quantitative results obtained by
MCR
-
ALS
are compared to those obtained using the well established partial least squares regression (PLSR) multivariate calibration method.
...
PMID:Application of multivariate curve resolution alternating least squares (MCR-ALS) to the quantitative analysis of pharmaceutical and agricultural samples. 1837 70
Visible circular dichroism (CD) spectra from the copper(II) titration of the metal-binding region of the prion protein, residues 57-98, were analyzed using the self-modeling curve resolution method multivariate curve resolution-alternating least squares (MCR-ALS).
MCR
-
ALS
is a set of mathematical tools for estimating pure component spectra and composition profiles from mixture spectra. Model-free solutions (e.g., soft models) are produced under the assumption that pure component profiles should be nonnegative and unimodal. Optionally, equality constraints can be used when the concentration or spectrum of one or more species is known.
MCR
-
ALS
is well suited to complex biochemical systems such as the prion protein which binds multiple copper ions and thus gives rise to titration data consisting of several pure component spectra with overlapped or superimposed absorption bands. Our study reveals the number of binding modes used in the uptake of Cu(2+) by the full metal-binding region of the prion protein and their relative concentration profiles throughout the titration. The presence of a non-CD active binding mode can also be inferred. We show that
MCR
-
ALS
analysis can be initialized using empirically generated or mathematically generated pure component spectra. The use of small model peptides allows us to correlate specific Cu(2+)-binding structures to the pure component spectra.
...
PMID:Characterization of Cu2+-binding modes in the prion protein by visible circular dichroism and multivariate curve resolution. 1838 Nov 99
Multivariate curve resolution coupled to alternating least-squares (MCR-ALS) has been employed to model kinetic-spectroscopic second-order data, with focus on the achievement of the important second-order advantage, under conditions of extreme spectral overlapping among sample components. A series of simulated examples shows that
MCR
-
ALS
can conveniently handle the studied analytical problem unlike other second-order multivariate calibration algorithms, provided matrix augmentation is implemented in the spectral mode instead of in the usual kinetic mode. The approach has also been applied to three experimental examples, which involve the determination of: (1) the antiparkinsonian carbidopa (analyte) in the presence of levodopa as a potential interferent, both reacting with cerium (IV) to produce the fluorescent species cerium (III) with different kinetics; (2) Fe(II) (analyte) in the presence of the interferent Zn(II), both catalyzing the oxidation of methyl orange with potassium bromate; and (3) tartrazine (analyte) in the presence of the interferent brilliant blue, both oxidized with potassium bromate, with the interferent leading to a product with an absorption spectrum very similar to tartrazine. The results indicate good analytical performance towards the analytes, despite the intense spectral overlapping and the presence of unexpected constituents in the test samples.
...
PMID:Second-order advantage from kinetic-spectroscopic data matrices in the presence of extreme spectral overlapping A multivariate curve resolution--alternating least-squares approach. 1840 80
<< Previous
1
2
3
4
5
6
7
8
9
10
Next >>