Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: UMLS:C0001511 (Adhesion)
5,955 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

Poly(vinyl pyrrolidone) (PVP) is widely used for bioengineering and pharmaceutical applications, and its adhesion characteristics are critical. When used as a binder in pharmaceutical granulation, it covers the resultant granules and governs their surface properties. The intrinsic adhesion forces of PVP toward common hydrophobic (magnesium stearate) and hydrophilic (lactose) pharmaceutical materials have been studied as a function of relative humidity (RH). The effect of RH on adhesion force was more significant for the PVP/hydrophilic material than the PVP/hydrophobic material. Adhesion was lowest between 20 and 40% RH, and it increased at RH above 40% and below 20%. This is likely to be due to the development of capillary and triboelectrification forces, respectively. In a nano-indentation experiment using a silicon tip at room temperature, the PVP surface underwent a glass transition at 70% RH. This result suggests that surface softening contributes to the increased PVP adhesion at RH above 70%. To adjust the adhesion properties of PVP, humidity control should be an essential part of research and development. Effect of humidity on the adhesion forces between PVP and lactose (LT) or magnesium stearate (MS).
...
PMID:Intrinsic adhesion properties of poly(vinyl pyrrolidone) to pharmaceutical materials: humidity effect. 1624 67

Skin flora immobilization technology is similar in efficacy to Iodine-Povidone in healthy volunteers. We did a prospective study in a university clinic with 60 healthy volunteers. Right inguinal skin area on healthy volunteers was used to compare the antimicrobial properties of cyanoacrylate sealant (FloraSeal, Adhesion Biomedical, Wyomissing, PA) versus standard surgical preparation Povidone-iodine (Betadine, Purdue Productions, Stamford, CT). Bacterial counts were measured at different time intervals: 15 minutes, 4 hours, and 24 hours. Bacterial colony forming units were compared between Povidone-iodine and cyanoacrylate sealant. The absolute log reduction was 5.568 for Povidone-iodine (7 absolute CFU); 5.028 for cyanoacrylate (59 absolute CFU); and 5.568 for Povidone-iodine and cyanoacrylate combined (21 absolute CFU). Cyanoacrylate was able to sustain a reduction on bacterial counts at 4 hours and 24 hours of more than 99.8 per cent as compared with the control group. Cyanoacrylate microbial sealant successfully reduces bacterial counts on normal healthy skin. The results were similar to Povidone-iodine alone. We believe this technology may be an excellent means of mitigating incisional surgical site infection by reducing the risk of contamination by skin flora and warrants further testing.
...
PMID:Novel bacterial immobilization compound effectively decreases bacterial counts in healthy volunteers. 2013 33