Query: UMLS:C0001511 (
Adhesion
)
5,955
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
The initial adhesion of oral bacteria to a tooth in vitro was examined. The organisms were grown in broth with and without sucrose, and suspensions made either in broth or a modified
Ringer's solution
. The tooth used was either dry or coated with natural or synthetic saliva.
Adhesion
was determined by counting organisms removed from the tooth surface by simple washing or by sonication. It was found that the firmest bonding occurred when a dry tooth was immersed in a suspension of bacteria in
Ringer's solution
; the prior growth of the organisms in the presence of sucrose did not affect adhesion. It was concluded that instantaneous irreversible adhesion of bacteria to a tooth occurs without the need for active metabolism, and that this process is inhibited by the presence of competing organic substances which probably produce a surface-conditioning film.
...
PMID:Factors affecting adhesion of bacterial to a tooth in vitro. 55 Dec 40
The objective of this study was to evaluate the initial tensile bond strength of a resin-modified glass ionomer (Photac-Fil) and two polyacid-modified composite resins (Compoglass, Dyract) to primary dentin. A hybrid composite resin (Tetric) and two chemical cured glass ionomers (BaseLine, Hi-Dense) served as controls. Ninety caries-free dentinal discs were ground flat and perfused with
Ringer's solution
. Dentinal surfaces were conditioned (except for Base Line). From each material, fifteen standardized specimens were attached to the dentin. Light-curing of the respective materials followed (1 min), and adhesion was tested with a universal testing machine 15 min after application. The highest initial bond strength was observed with Tetric (5.17 MPa). Closed test procedure (Kruskal-Wallis) showed significant differences between all materials (P < 0.05), except for Compoglass (1.82 MPa) vs. Dyract (2.35 MPa), and BaseLine (0.37 MPa) vs. Photac-Fil (0.42 MPa). The condensable glass ionomer Hi-Dense revealed a mean tensile bond strength of 0.79 MPa.
Adhesion
of (polyacid-modified) composite resins is superior to the other tested glass ionomer materials, when applied to perfused primary dentin.
...
PMID:Initial tensile bond strength of resin-modified glass ionomers and polyacid-modified resins on perfused primary dentin. 926 99