Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: KEGG:D06502 (Poloxamer 188)
217 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

Severe hemoglobinuria was observed in a case with abdominal aortic aneurysm on the 23rd postoperative day. The typical continuous murmur was heard on the right upper chest, and IADSA revealed an A-V fistula connecting between the right subclavian artery and the internal jugular vein. This A-V fistula was thought to have been caused by an inadvertent arteriopuncture during the central venous cannulation at the time of the operation. Poloxamer 188 (a non-ionic surfactant) and haptoglobin were given intravenously, and they proved to be quite effective in improving intravascular mechanical hemolysis and hemoglobinuria. A division of the A-V fistula was done successfully, which was facilitated by the median sternotomy combined with the extension of the skin incision to the neck. It cannot be overemphasized that utmost care should be taken to prevent any complication at the time of the central venous cannulation.
...
PMID:[A case of A-V fistula with severe hemolysis following internal jugular venipuncture]. 318 99

This study was performed to evaluate the effects of Exocorpol and Haptoglobin on hemolysis during ECC. We measured free hemoglobin (F-Hb) and free haptoglobin (F-Hp) at pre- and post-ECC. Patients were divided four groups: Group C, 5 patients undergoing no treatment; Group Ex, 5 patients undergoing treatment of Exocorpol; Group Hp, 5 patients undergoing treatment of Haptoglobin; Group Ex + Hp, 5 patients undergoing treatment of Exocorpol and Haptoglobin. F-Hb of pre- and post-ECC in four groups were 0 mg/dl: 85 mg/dl (Group C, p < 0.01), 0 mg/dl: 2 mg/dl (Group Ex, NS), 0 mg/dl: 1 mg/dl (Group Hp, NS), 0 mg/dl: 0 mg/dl (group Ex + Hp, NS). F-Hp of pre- and post-ECC in four groups were 143 mg/dl: 9 mg/dl (Group C, p < 0.02), 133 mg/dl: 25 mg/dl (Group Ex, p < 0.05), 186 mg/dl: 195 mg/dl (Group Hp, NS), 66 mg/dl: 163 mg/dl (Group EX + Hp, p < 0.05). There was no significant difference in F-Hb and F-Hp of pre-ECC among four groups. F-Hb of post-ECC in Group C was significantly higher than that of Group Ex, Hp and Ex + Hp (p < 0.01), and F-Hp of post-ECC in Group Hp and Ex + Hp was significantly higher than that of Group C and Ex.(p < 0.01, p < 0.02). We concluded that Exocorpol and Haptoglobin were effective on hemolysis during ECC, and combination of these was more effective.
...
PMID:[Effects of exocorpol and haptoglobin on hemolysis during ECC]. 930 46