Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: EC:6.3.5.5 (CPS)
1,262 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

N-Acetyl-L-glutamate has been examined with regard to its ability to activate carbamoyl phosphate synthetase I (EC 6.3.4.16). Substance(s) inhibitory to carbamoyl phosphate synthetase, present even in the partially purified preparation of rat liver extracts, interfered with the measurement of acetylglutamate. In the experiments using chelating agents, metals were apparently involved in this inhibition. When the partially purified preparation of liver extract was placed on a Chelex 100 column, the inhibitor was eliminated and accurate measurements of acetylglutamate content could be made. Evidence supporting the validity of this improved method is given. A significant difference was observed between acetylglutamate levels determined by the present method and by the one using aminoacylase I (N-acylamino acid amidohydrolase, EC 3.5.1.14) to hydrolyze acetylglutamate followed by assay of the glutamate generated. We searched for the presence of glutamate derivatives other than acetylglutamate. When impure tissue preparations containing acetylglutamate were treated with a commercial preparation of aminoacylase, there was an excess amount of glutamate apparently derived from compounds other than acetylglutamate. This can lead to an overestimation of the tissue levels of acetylglutamate.
...
PMID:An improved method for determination of N-acetyl-L-glutamate by its function as an activator of carbamoyl phosphate synthetase I. 230 60

Acetylglutamate in HClO4 tissue extracts is first separated from glutamate by ion exchange. It is then deacylated with aminoacylase, and the resulting glutamate, after adsorption to and elution from an AG 50 column, is quantitated by a fast-HPLC method using o-phthaldialdehyde precolumn derivatization, separation in a C18 reverse-phase column, and fluorescence detection. A linear response is obtained up to 2 nmol, the detection limit is 5 pmol, and the method is suitable for assay in 1 mg liver tissue and thus for needle biopsies. When samples were analyzed by this procedure and by earlier procedures based upon detection of glutamate with glutamate dehydrogenase or upon activation of carbamoyl phosphate synthetase the results were similar. The method, which is highly specific, compares favorably in sensitivity, precision, and accuracy with all other published procedures. Using this assay, no acetylglutamate has been found in chicken liver and rat kidney.
...
PMID:Determination of N-acetyl-L-glutamate using high-performance liquid chromatography. 399 35