Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: EC:6.3.4.6 (urease)
7,490 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

Two new methods of activation were developed to graft enzymes on collegen films. They involved chemical modifications of surface groups of collagen either by Woodward's reagent "K" or by EDC, a water-soluble derivative of carbodiimide. EDC was a better coupling agent and a detailed study was conducted with this agent. It could be used either in a global method of activation and coupling, or in a two-step procedure of activation of collagen, followed by spontaneous coupling of enzyme. All enzymes tested were successfully bound: malate dehydrogenase, lactate dehydrogenase, aspartate aminotransferase, urease, creatine kinase, hexokinase. The influence on the yield of grafted enzyme, of pretreatment of films, time and temperature of EDC activation, concentration of EDC and enzyme, protecting agents was studied. Stability of enzyme activity on storage was greatly increased after grafting. A co-grafted dual system creatine kinase/heoxkinase, was achieved which exhibited a good efficiency. A striking renaturing process at 0-4degreesC after thermal denaturation, was observed with hexokinase.
...
PMID:Grafting of enzymes on collagen films using Woodward's reagent "K" and a water-soluble carbodiimide derivative. 95 53

Special surface acoustic wave (SAW) devices using horizontally polarized surface shear waves can be operated in water. They allow an easy detection of molecules with biological relevance (e.g., proteins) via direct detection of the adsorbed mass. The transducer structures of conventional SAW devices are usually connected to the electronics by bond wires. In consequence, flow cell volumes can hardly be designed smaller than 50 microL. A new type of SAW device that is coupled capacitively with the electronics enables the reduction of flow cell volumes down to 60 nL, which decreases sample consumption and reduces the length of the measurement cycles down to a few minutes. To create an immunosensor, the SAW devices first are coated with a thin parylene layer for creating a sensor surface that is chemically homogeneous. Then OptoDex, a dextran containing both photoactive and functional groups is immobilized photochemically. Finally, antibodies are coupled via conventional EDC/NHS chemistry. The technique has been used to monitor urease binding at anti-urease-coated SAW devices in real time and with good resolution. Because of the simple sensor handling and the economical sample use, the new SAW device is particularly suitable for the design of an array.
...
PMID:A surface acoustic wave biosensor concept with low flow cell volumes for label-free detection. 1471 Aug 39