Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: EC:6.2.1.1 (ACS)
78,556 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

A patient presented with an acute inferior myocardial infarction. Coronary angiography in the acute stage revealed total occlusion of the right coronary artery. Reperfusion was obtained after intracoronary infusion of 250,000 units of streptokinase. Angioplasty was subsequently performed because of a high grade residual stenosis. An 8-French right Judkins guiding catheter with a single side hole (USCI), a 3.0 mm balloon dilatation catheter (ACS), and a 0.018 high torque floppy guide wire (ACS) were used. After successful angioplasty angiography was repeated with the guide wire in the RCA, but the balloon was withdrawn into the guiding catheter. After injection of contrast, it was impossible to withdrawn the balloon catheter out of the guiding catheter. Fluoroscopy revealed extrusion of the balloon through the side hole in the guiding catheter.
...
PMID:Inadvertant balloon extrusion through a side hole in a guiding catheter. 395 42

We report on a case of coronary embolization of an elastic membrane fixing the ACS RX Multilink stent over its balloon, after a successful stent delivery. The membrane was dislodged from the balloon in the ostium of the right coronary artery as the delivery balloon was being pulled back into the guiding catheter. All attempts to retrieve the membrane, to cover it with another stent, or to push it into a terminal segment of the artery to limit the jeopardized myocardial mass were unsuccessful. No CABG was performed because the left coronary system was normal and the procedure occurred 2 months after an incomplete inferior myocardial infarction. There was no increase in cardiac enzymes nor electrocardiographic signs of a new myocardial infarction at discharge or at 1-mo follow-up. It seems preferable to avoid further use of stents tied to their balloons with an intermediary, and possibly detachable, element.
...
PMID:Coronary embolization of the membrane fixing a "Multilink" stent to its delivery balloon. 947 95

In an effort to prevent metastasis of breast tumor cells- at the same time of inhibiting tumor growth with less toxic side effects, honokiol (HNK) was encapsulated into pH-sensitive polymeric micelles based on the conjugate of poly(2-ethyl-2-oxazoline)-poly(d,l-lactide) (PEOz-PLA) with doxorubicin (DOX), denoted as PEOz-PLA-imi-DOX. PEOz-PLA-imi-DOX was successfully synthesized by connecting DOX to the hydrophobic end of PEOz-PLA via acid-cleavable benzoic imine linker. HNK-loaded conjugate micelles (HNK/PP-DOX-PM) with a size of 21 nm and homogeneous spherical shape exhibited high drug-loading capacity. PEOz-PLA-imi-DOX and HNK/PP-DOX-PM displayed faster release of DOX at pH 5.0 than at pH 7.4. As anticipated, PEOz-PLA-imi-DOX maintained cytotoxicity of DOX against MDA-MB-231 cells. The synergistically enhanced in vitro antitumor effect of HNK/PP-DOX-PM was confirmed by their synergetic inhibition of MDA-MB-231 cell growth. Furthermore, the efficient prevention of tumor metastasis by HNK/PP-DOX-PM was testified by in vitro anti-invasion, wound healing and antimigration assessment in MDA-MB-231 cells, and in vivo bioluminescence imaging in nude mice. The suppression of growth and metastasis of tumor cells by HNK/PP-DOX-PM was attributed to the synergistic effect of pH-triggered drug release and HNK-aroused inhibition of matrix metalloproteinases and epithelial-mesenchymal transition, respectively. In addition, HNK/PP-DOX-PM exhibited superior biosafety than physically encapsulated dual-drug micelles. Consequently, the fabricated HNK/PP-DOX-PM may have great potential for safe and effective suppression of tumor growth and metastasis.
ACS Appl Mater Interfaces 2018 Jun 06
PMID:Synergistically Enhanced Antimetastasis Effects by Honokiol-Loaded pH-Sensitive Polymer-Doxorubicin Conjugate Micelles. 2974 28