Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Pivot Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Target Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Query: EC:4.1.1.6 (
CAD
)
4,420
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
Long-term performance of Starr-Edwards silastic ball (SESB, n = 168) and St Jude Medical bi-leaflet (SJMB, n = 93) valves in patients who were alive 30 days after implantation (1980-86) for aortic stenosis was compared. Mean follow-up was 3.0 years (0.1-7.9 years). The SESB and SJMB groups differed as regards female gender (18% vs 47%, P less than 0.0001), NYHA classes III-IV (59% vs 72%, P less than 0.05), coronary artery disease (
CAD
, 32% vs 62%, P less than 0.01) in patients with coronary arteriography (n = 82 and n = 55, respectively), and prosthetic annulus diameter (26 +/- 1 vs 23 +/- 2 mm, P less than 0.0001). Five-year survival +/- SE in SESB vs SJMB patients was: total population, 89 +/- 3% vs 80 +/- 6% (NS); coronary arteriography population, no
CAD
, 90 +/- 4% vs 100% (NS), and with
CAD
, 71 +/- 11% vs 60 +/- 13% (NS; P = 0.01 for
CAD
). Five-year event-free survival +/- SE in SESB vs SJMB patients was 95 +/- 2% vs 97 +/- 2% (NS) for thromboembolism, 95 +/- 2% vs 89 +/- 4% (NS) for
coumadin
-related haemorrhage, 98 +/- 1% vs 99 +/- 1% (NS) for endocarditis, 98 +/- 1% vs 94 +/- 5% (NS) for paravalvular leak, 88 +/- 3% vs 79 +/- 6% (NS) for all valve-related complications, and 98 +/- 1% vs 95 +/- 4% (NS) for prosthesis replacement. Thrombotic occlusion or structural failure were not observed. No patients without
CAD
experienced thromboembolic events. Cox regression analyses (in both total population and coronary arteriography population) of survival as well as the various complications revealed that the type of prosthesis did not have predictive influence.
CAD
was an independent risk factor for thromboembolism, haemorrhage, and all valve-related complications. Previous systemic hypertension was independently predictive of haemorrhage. The SESB and SJMB prostheses showed comparable and acceptable long-term performance. Only patient-related variables, notably
CAD
, influenced late results. The proven durability and relatively low price of the SESB valves together with the excellent haemodynamic performance of even small-sized SJMB valves should be considered in the light of the present results.
...
PMID:Long-term performance of Starr-Edwards silastic ball valves and St Jude Medical bi-leaflet valves. A comparative analysis of implantations during 1980-86 for aortic stenosis. 231 12
Diabetes mellitus patients after aorto-coronary bypass operation constitute a patient cohort at largely increased risk for secondary coronary events. Antiplatelet agents and antithrombotic agents are applied for secondary prevention. Up to now, secondary prevention has not been addressed specifically in the cohort of diabetic patients after bypass operation. Hence therapeutic recommendations are derived from the global cohort of
CAD
patients and based on risk assessment rather than on specific data. Since diabetic patients after myocardial infarction are at particularly high risk, combined therapy with clopidogrel and ASS may be considered even with restricted resources in the health system. Oral anticoagulation with
coumadin
constitutes an effective alternative to dual anti-platelet therapy. Under specific conditions (ventricular aneurysms, EF < 30%, or certain conditions in coronary anatomy) oral anticoagulants should be considered more liberally than currently.
...
PMID:[Postoperative antithrombotic treatment in diabetic patients]. 1659 54