The purpose of this study was to evaluate prospectively the feasibility and accuracy of using echocardiographic measurements by transesophageal and intracardiac echocardiography (TEE and
ICE
, respectively) for interatrial
septal defect
sizing during percutaneous transcatheter closure. Forty-two patients underwent balloon sizing of interatrial septal defects using TEE in 21 of them and
ICE
in the other half. These measurements were correlated with quantitative fluoroscopic analysis and evaluated for bias and agreement between methods using a Bland-Altman analysis. Echocardiographic measurements were obtained by
ICE
and TEE in all patients. An excellent correlation was found between TEE and quantitative fluoroscopy (r = 0.898; P < 0.001) and between
ICE
and quantitative fluoroscopy (r = 0.876; P < 0.001), with a significant agreement (P < 0.001) and minimal positive bias toward the echocardiographic measurements. Both TEE and
ICE
are excellent methods of interatrial defect sizing when compared with quantitative fluoroscopic measurements.
...
PMID:Interatrial defect sizing by intracardiac and transesophageal echocardiography compared with fluoroscopic measurements in patients undergoing percutaneous transcatheter closure. 1522 15