Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Pivot Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Target Concepts:
Gene/Protein
Disease
Symptom
Drug
Enzyme
Compound
Query: EC:3.4.21.6 (
thromboplastin
)
13,278
document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)
The lupus anticoagulant (LA) phenomenon created world-wide interest recently. Various tests have been devised to identify LA in plasma, but none of these methods have been universally accepted. In this study 16 cases labelled LA positive by a prior kaolin clotting time (KCT) test were reassessed by four other methods, namely delta KCT (delta kaolin clotting time), APTT (activated partial
thromboplastin
time),
PNP
(platelet neutralization procedure), and DRVVT (dilute Russell viper venom time). Anti-cardiolipin antibodies (ACL) were also looked for. In our hands the delta KCT proved to be a simple, sensitive test, not influenced by oral anticoagulant therapy, and we recommend it as a screening test. Where the presence of LA is strongly suspected on clinical and other groups, more than one method may be necessary for the diagnosis.
...
PMID:Comparison of four laboratory tests for lupus anticoagulant. 212
In 1994, the, French National Quality Control Group for Hematology, Etalonorme, conducted a large-scale interlaboratory survey concerning the detection of lupus anticoagulants (LA) involving all the 4,500 French laboratories. Each laboratory received the same batch of a lyophilized citrated plasma (94B3) prepared from a patient with LA that had been confirmed by all the techniques used in the intralaboratory study. In the interlaboratory survey, the screening test was activated partial
thromboplastin
time (APTT); mean APTT calculated from the results reported by 4,029 labs was prolonged (clotting ratio = 1.44) with a large dispersion (coefficients of variation = 18.8%). APTT of the mixture 94B3 + normal plasma were performed by 2,698 laboratories. No correction of APTT was obtained (R = 1.36, Rosner index = 24) with a wide variation between reagents (17 < Rosner index < 39). Only 15% of the participants performed confirmatory tests; dilute tissue
thromboplastin
inhibition test (TTI) performed by 509 laboratories gave 75% positive results. Tests with an increased amount of phospholipids (Staclot LA and Staclot
PNP
from Diagnostica Stago), used by 116 and 72 laboratories, gave 88% and 61% positive results, respectively. A total of 1,862 laboratories made the diagnosis of LA. The majority of those who failed in diagnosing LA used an APTT reagent largely used in France, containing kaolin. This survey allowed Etalonorme to inform French biologists and draft an educational program for the biologic detection of LA and the identification of its mechanism of action.
...
PMID:Lupus anticoagulants: first French interlaboratory Etalonorme survey. 865 56