Gene/Protein Disease Symptom Drug Enzyme Compound
Pivot Concepts:   Target Concepts:
Query: EC:3.4.21.5 (thrombin)
33,306 document(s) hit in 31,850,051 MEDLINE articles (0.00 seconds)

D-dimer and thrombin-antithrombin III complex (TAT) were assayed in 11 patients at various times pre- and post-operatively in order to determine the possible value of these parameters in screening for thromboembolic complications. Phlebography revealed distal thrombosis in 6 of the 11 patients. The D-dimer level, already elevated before surgery, increased at day 1 and remained high at days 5 and 10. Two methods were used for the assays and showed strongly correlated results. The TAT level increased at day 1 and then progressively returned toward basal values. No difference was observed at any time between patients with or without thrombosis. The results in surgical patients undergoing knee replacement suggest that neither D-dimer nor TAT assays are valid screening procedures for post-operative DVT. Nevertheless, in view of the small number of patient studied, further work is required to confirm these results.
...
PMID:D-dimer and thrombin-antithrombin III complex levels uncorrelated with phlebographic findings in 11 total knee replacement patients. 219 59

The study was carried out of 53 patients with acute myocardial infarction receiving no anticoagulant treatment. Changes were traced in certain indices of the blood clotting system and fibrinolysis in plasma in the first 14 days of the disease, with particular attention given to patients in whom during the hospitalization signs of deep vein thrombosis in the lower extremities appeared or a positive result was obtained of the test with 125I-fibrinogen. In a group of 9 patients with deep vein thrombosis developing during the observation, on the first day of myocardial infarction shortening of the kaolin-cephalin clotting time and considerable rise of the level of fibrinogen-fibrin (FDP) degradation products were noted in serum, and on the 14th day raised fibrinogen level and reduced exogenous fibrinolytic activity of the plasma were noted. Increased level of fibrinogen and FDP and exogenous and endogenous plasma fibrinolytic activity observed on the 7th day of the disease were not related to the development of thrombotic complications. The thrombin clotting time, platelet count, factor X level, protein C concentration and antithrombin III activity in the plasma were not significantly changed during myocardial infarction. The obtained results suggest a limited usefulness of the basic tests of the clotting and fibrinolytic systems for early diagnosis of deep vein thrombosis in acute myocardial infarction.
...
PMID:[Assessment of hemostasis in patients with myocardial infarction complicated by deep venous thrombosis]. 227 86

We describe a familial study of AT III, a type III antithrombin III variant which was identified in the propositus by gene analysis as Pro 41 Leu heterozygous mutation. None of the four members of the family who presented with defective heparin cofactor (hep-cofactor) activity, and therefore probably carried the mutation, had experienced deep venous thrombosis. The abnormal AT III was purified from the propositus' plasma, taking advantage of the difference in NaCl concentrations required to elute variant and normal AT III from heparin-Sepharose. The antithrombin and anti-Xa activities of the purified variant AT III were comparable to those observed for normal AT III, but hep-cofactor activity was strikingly reduced. The enhancement by heparin of thrombin and F Xa inhibition by normal and variant AT III was compared in the absence of NaCl and in the presence of normal NaCl concentrations. The difference between the degrees of inhibition by normal and variant AT III was maximal at physiological ionic strength (i.e. at a concentration of 0.15 M). The quantification of heparin AT III interaction with both normal and variant purified proteins in a double reciprocal plot yielded similar dissociation constants but a 9-fold decrease in the maximal pseudo-first order constant. This suggests that Pro 41 is more involved in the molecular changes induced by heparin than in the primary binding of the activator.
...
PMID:Clinical and biochemical characterization of antithrombin III Franconville, a variant with Pro 41 Leu mutation. 237 10

Plasma levels of betathromboglobulin (BTG), fibrinopeptide A (FPA) and B beta 15-42 fragment, indices of platelet release, thrombin generation and plasmin activity respectively, were measured in 32 high risk patients during a double blind study of a single dose of the anabolic steroid stanozolol (50 mg IM) in the prevention of DVT after major gastro-intestinal surgery. The prevalence of malignancy and the incidence of DVT (125I fibrinogen scan) were similar in the two treatment groups. On the first postoperative day, BTG, FPA and B beta 15-42 levels were increased in most patients. Plasma BTG levels were significantly increased on the first post-operative day in patients who developed a DVT (n = 14) compared to those patients who did not (n = 18). A significant increase in FPA levels was found in the DVT group, 7 days after surgery. On the morning before surgery, plasma B beta 15-42 levels were significantly increased in patients who developed a DVT. In patients undergoing surgery for early malignancy (n = 17), we observed a pre-operative increase in FPA levels when compared to patients without malignancy. At post-operative day 7, B beta 15-42 levels were significantly increased in patients who received stanozolol (n = 15), when compared to the placebo group, suggesting that intramuscular stanozolol increases fibrinolysis in vivo.
...
PMID:Plasma beta-thromboglobulin, fibrinopeptide A and B beta 15-42 antigen in relation to postoperative DVT, malignancy and stanozolol treatment. 241 Sep 95

We have developed a specific and sensitive ELISA for the measurement of the TAT in human plasma. The assay follows the sandwich principle and uses two different antibodies directed against human thrombin and human antithrombin III, respectively. The anti-thrombin antibody population used for coating was purified by immunoadsorption on immobilized prothrombin and thrombin, respectively. Antithrombin III antibodies were conjugated with peroxidase. Plasma samples containing TAT were incubated in polystyrene tubes coated with anti-thrombin antibodies; after washing, peroxidase-conjugated antithrombin III antibodies were added and bound enzyme activity was subsequently measured using o-phenylenediamine. The assay was calibrated with definite concentrations (2.0 to 60 micrograms/l) of preformed purified TAT added to TAT-poor plasma. Plots of absorbance at 492 nm against TAT concentrations revealed a linear correlation (r = 0.98). A reference range from 0.85 to 3.0 micrograms/l was calculated from TAT concentration in plasma samples from 88 healthy donors (mean value +/- SD: 1.45 +/- 0.4 micrograms/l). In patients with deep vein thrombosis confirmed by phlebography (n = 15), TAT was found up to 7-13 micrograms/l. Patients with septicemia associated with a consumption coagulopathy (n = 10) showed markedly increased TAT values (greater than or equal to 10 micrograms/l). From these data it can be concluded that measurement of TAT might be a parameter for detection of a latent clotting pathway activation.
...
PMID:Determination of human thrombin-antithrombin III complex by enzyme immunoassay. 246 14

In 196 consecutive patients who underwent elective total hip surgery we investigated the diagnostic accuracy of the thrombin-antithrombin III complex immunoassay, as assessed on the first, fourth and tenth postoperative day, for the development of deep vein thrombosis (DVT). Patients received either LMW-heparinoid (n = 97) or placebo (n = 99) and underwent contrast venography on the tenth postoperative day. Thrombin-antithrombin III (T-AT) plasma levels were raised in all patients on the first postoperative day and gradually decreased during the study period. T-AT plasma levels were significantly higher in patients developing DVT when compared to patients without DVT and remained so until day 10. This difference was apparent both in the LMW-heparinoid group as well as in the placebo-treated patients. ROC-curve analysis revealed no satisfactory discriminative power for the diagnosis of developing DVT at any of the studied cut-off values for T-AT. We conclude that the postoperative determination of T-AT complex plasma concentrations in hip surgery patients has no clinical utility in the prediction of postoperative DVT.
...
PMID:Thrombin-antithrombin III complexes in the prediction of deep vein thrombosis following total hip replacement. 255 85

The antithrombin III (ATIII) isoform patterns of plasma and serum samples from cancer patients and controls were analysed by isoelectric focusing and immunoblotting. A novel ATIII banding pattern was identified in two individuals: a patient with breast carcinoma who developed deep venous thrombosis and a blood donor. Family studies in the patient showed the abnormal pattern to be due to a mutant form of ATIII (AT Dublin 2). The coagulation properties of AT Dublin 2 heterozygotes were normal. Immunologic and activity levels of ATIII, measured by standard techniques, were normal. Mutant plasma ATIII showed reduced thrombin reactivity at low concentrations of thrombin and demonstrated decreased reactivity with heparin over a range of heparin concentrations. This was confirmed using a modified ATIII heparin cofactor activity assay with varying heparin concentrations. The abnormal ATIII was also found to elute from heparin agarose at a lower ionic strength than normal ATIII. Two dimensional gel electrophoresis showed the abnormal ATIII to have similar molecular size distribution to normal ATIII. Neuraminidase treatment of normal and mutant plasma reduced the ATIII isoforms to one in both samples. The possible role of AT Dublin 2 in predisposing to hypercoagulation is discussed.
...
PMID:Identification and characterisation of an antithrombin III mutant (AT Dublin 2) with marginally decreased heparin reactivity. 260 89

To study the effect of heparin on thrombin formation in vivo, we measured thrombin-antithrombin III complexes (TAT) in 26 patients treated with heparin for acute coronary artery disease or deep vein thrombosis. There was a statistically significant correlation between activated partial thromboplastin time and heparin concentration, but none was found between these tests and TAT. Abnormal TAT values in 45% of the patients showed that therapeutic heparin concentration did not inhibit thrombin formation in vivo, or did so only partially.
...
PMID:[Thrombin-antithrombin III complexes as a measure of effective heparin treatment?]. 267 51

We describe a 43-year-old male patient with congenital antithrombin III deficiency requiring haemodialysis due to extension of venous thrombus from recurrent deep vein thrombosis. During dialysis with adequate heparinization, the patient often revealed clot formation in the extracorporeal circuit resulting in unexpected discontinuation of dialysis. When either a combination of antithrombin III concentrate plus heparin or the newly developed synthetic antithrombin preparation, MD805, was infused during dialysis, he could be uneventfully dialysed with either of the two regimens. The functional antithrombin III activity with MD805 increased to the same level as that obtained with antithrombin III concentrate, and it was possible to achieve an antithrombotic effect, as measured from the APTT and thrombin-antithrombin III complex with MD805 during and after dialysis. We thus found that MD805 could be used as an anticoagulant drug when an AT III-deficient patient required anticoagulation in the extracorporeal circulation.
...
PMID:Choice of anticoagulant in a congenital antithrombin III (AT III)-deficient patient with chronic renal failure undergoing regular haemodialysis. 268 3

We studied the diagnostic value of recently introduced ELISA's for the determination of thrombin-antithrombin III (TAT) complexes, fibrin degradation products (FbDP), fibrinogen degradation products (FgDP) and total degradation products (TDP) for deep venous thrombosis (DVT) in plasma of 239 consecutive outpatients, suspected for DVT by their family doctor. DVT was confirmed by impedance plethysmography in 60 patients. Using the 95th percentile range of 42 healthy volunteers the sensitivity for the detection of DVT was: 37% for TAT, 95% for TDP, 92% for FbDP and 90% for FgDP. Specificity was: 88% for TAT, 16% for TDP, 20% for FbDP and 25% for FgDP. We conclude that these assays are of little value in the diagnosis of DVT in outpatients.
...
PMID:Is quantitative determination of fibrin(ogen) degradation products and thrombin-antithrombin III complexes useful to diagnose deep venous thrombosis in outpatients? 269 21


<< Previous 1 2 3 4 5 6 7 8 9 10 Next >>